基于半导体激光器同时测量旋转轴的六自由度运动误差的方法和系统。

IF 3.2 2区 物理与天体物理 Q2 OPTICS
Optics express Pub Date : 2023-07-17 DOI:10.1364/OE.493982
Dong Ma, JiaKun Li, Qibo Feng, YuQiong Zhao, Jianying Cui, Lihong Wu
{"title":"基于半导体激光器同时测量旋转轴的六自由度运动误差的方法和系统。","authors":"Dong Ma,&nbsp;JiaKun Li,&nbsp;Qibo Feng,&nbsp;YuQiong Zhao,&nbsp;Jianying Cui,&nbsp;Lihong Wu","doi":"10.1364/OE.493982","DOIUrl":null,"url":null,"abstract":"<p><p>The rotary axis is the basis of rotational motion. The motion errors of a rotary axis have an extremely important impact on the accuracy of precision machining measuring equipment such as CNC machines, robot manipulators, and laser trackers. It is a difficult problem to realise the fast and precision simultaneous measurement of multi-degree-of-freedom motion errors of a rotary axis. Therefore, a novel method for the simultaneous measurement of six-degree-of-freedom motion errors of a rotary axis by a single-mode fiber coupled semiconductor laser is proposed in this paper. The corresponding system is developed, which has the advantages of high measurement efficiency, simple structure and low cost. A phase-solving method taking the advantages of both the eight-subdivision and the Cordic algorithm is proposed to solve the phase of interference signal, cannot only realize the high-resolution solving of the current signal phase but also quickly obtain high-precision interferometric results. A series of experiments were carried out on the developed system. An experimental system was built and a series of experiments were performed. The experimental results show that the standard deviation of stability for 1 hour of the six-degree-of-freedom measurement is 0.03 µm, 0.02 µm, 0.03 µm, 0.10 <sup><i>'</i> <i>'</i></sup> , 0.05 <sup><i>'</i> <i>'</i></sup> and 0.03 <sup><i>'</i> <i>'</i></sup> , respectively. The repeatability deviation of measuring a rotary axis is ±0.16 µm, ± 0.29 µm, ± 0.25 µm, ± 0.65 <sup><i>'</i> <i>'</i></sup> , ± 0.62 <sup><i>'</i> <i>'</i></sup> and ±13.42 <sup><i>'</i> <i>'</i></sup> , respectively. The maximum deviation of comparison with standard instruments is 0.46 µm, 1.00 µm, 0.49 µm, 1.06 <sup><i>'</i> <i>'</i></sup> , 1.53 <sup><i>'</i> <i>'</i></sup> and 0.74 <sup><i>'</i> <i>'</i></sup> , respectively. It provides a low-cost and high-precision measurement method for simultaneous measurement of six-degree-of-freedom motion errors of rotary axis of precision machining and measuring equipment.</p>","PeriodicalId":19691,"journal":{"name":"Optics express","volume":"31 15","pages":"24127-24141"},"PeriodicalIF":3.2000,"publicationDate":"2023-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Method and system for simultaneously measuring six degrees of freedom motion errors of a rotary axis based on a semiconductor laser.\",\"authors\":\"Dong Ma,&nbsp;JiaKun Li,&nbsp;Qibo Feng,&nbsp;YuQiong Zhao,&nbsp;Jianying Cui,&nbsp;Lihong Wu\",\"doi\":\"10.1364/OE.493982\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The rotary axis is the basis of rotational motion. The motion errors of a rotary axis have an extremely important impact on the accuracy of precision machining measuring equipment such as CNC machines, robot manipulators, and laser trackers. It is a difficult problem to realise the fast and precision simultaneous measurement of multi-degree-of-freedom motion errors of a rotary axis. Therefore, a novel method for the simultaneous measurement of six-degree-of-freedom motion errors of a rotary axis by a single-mode fiber coupled semiconductor laser is proposed in this paper. The corresponding system is developed, which has the advantages of high measurement efficiency, simple structure and low cost. A phase-solving method taking the advantages of both the eight-subdivision and the Cordic algorithm is proposed to solve the phase of interference signal, cannot only realize the high-resolution solving of the current signal phase but also quickly obtain high-precision interferometric results. A series of experiments were carried out on the developed system. An experimental system was built and a series of experiments were performed. The experimental results show that the standard deviation of stability for 1 hour of the six-degree-of-freedom measurement is 0.03 µm, 0.02 µm, 0.03 µm, 0.10 <sup><i>'</i> <i>'</i></sup> , 0.05 <sup><i>'</i> <i>'</i></sup> and 0.03 <sup><i>'</i> <i>'</i></sup> , respectively. The repeatability deviation of measuring a rotary axis is ±0.16 µm, ± 0.29 µm, ± 0.25 µm, ± 0.65 <sup><i>'</i> <i>'</i></sup> , ± 0.62 <sup><i>'</i> <i>'</i></sup> and ±13.42 <sup><i>'</i> <i>'</i></sup> , respectively. The maximum deviation of comparison with standard instruments is 0.46 µm, 1.00 µm, 0.49 µm, 1.06 <sup><i>'</i> <i>'</i></sup> , 1.53 <sup><i>'</i> <i>'</i></sup> and 0.74 <sup><i>'</i> <i>'</i></sup> , respectively. It provides a low-cost and high-precision measurement method for simultaneous measurement of six-degree-of-freedom motion errors of rotary axis of precision machining and measuring equipment.</p>\",\"PeriodicalId\":19691,\"journal\":{\"name\":\"Optics express\",\"volume\":\"31 15\",\"pages\":\"24127-24141\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2023-07-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optics express\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1364/OE.493982\",\"RegionNum\":2,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optics express","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/OE.493982","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

摘要

旋转轴是旋转运动的基础。旋转轴的运动误差对数控机床、机器人和激光跟踪器等精密加工测量设备的精度有着极其重要的影响。实现旋转轴多自由度运动误差的快速、精确同时测量是一个难题。因此,本文提出了一种用单模光纤耦合半导体激光器同时测量旋转轴六自由度运动误差的新方法。开发了相应的测量系统,具有测量效率高、结构简单、成本低等优点。提出了一种同时利用八次细分和Cordic算法的相位求解方法来求解干涉信号的相位,不仅可以实现对当前信号相位的高分辨率求解,而且可以快速获得高精度的干涉测量结果。在所开发的系统上进行了一系列实验。建立了实验系统,并进行了一系列实验。实验结果表明,六自由度测量1小时的稳定性标准偏差为0.03 µm,0.02 µm,0.03 µm,分别为0.10''、0.05''和0.03''。测量旋转轴的重复性偏差为±0.16 µm, ± 0.29 µm, ± 0.25 µm, ± 0.65’’, ± 0.62’’和±13.42’’’。与标准仪器比较的最大偏差为0.46 µm,1.00 µm,0.49 µm、1.06''、1.53'''和0.74'。为精密加工测量设备的旋转轴六自由度运动误差的同时测量提供了一种低成本、高精度的测量方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Method and system for simultaneously measuring six degrees of freedom motion errors of a rotary axis based on a semiconductor laser.

The rotary axis is the basis of rotational motion. The motion errors of a rotary axis have an extremely important impact on the accuracy of precision machining measuring equipment such as CNC machines, robot manipulators, and laser trackers. It is a difficult problem to realise the fast and precision simultaneous measurement of multi-degree-of-freedom motion errors of a rotary axis. Therefore, a novel method for the simultaneous measurement of six-degree-of-freedom motion errors of a rotary axis by a single-mode fiber coupled semiconductor laser is proposed in this paper. The corresponding system is developed, which has the advantages of high measurement efficiency, simple structure and low cost. A phase-solving method taking the advantages of both the eight-subdivision and the Cordic algorithm is proposed to solve the phase of interference signal, cannot only realize the high-resolution solving of the current signal phase but also quickly obtain high-precision interferometric results. A series of experiments were carried out on the developed system. An experimental system was built and a series of experiments were performed. The experimental results show that the standard deviation of stability for 1 hour of the six-degree-of-freedom measurement is 0.03 µm, 0.02 µm, 0.03 µm, 0.10 ' ' , 0.05 ' ' and 0.03 ' ' , respectively. The repeatability deviation of measuring a rotary axis is ±0.16 µm, ± 0.29 µm, ± 0.25 µm, ± 0.65 ' ' , ± 0.62 ' ' and ±13.42 ' ' , respectively. The maximum deviation of comparison with standard instruments is 0.46 µm, 1.00 µm, 0.49 µm, 1.06 ' ' , 1.53 ' ' and 0.74 ' ' , respectively. It provides a low-cost and high-precision measurement method for simultaneous measurement of six-degree-of-freedom motion errors of rotary axis of precision machining and measuring equipment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Optics express
Optics express 物理-光学
CiteScore
6.60
自引率
15.80%
发文量
5182
审稿时长
2.1 months
期刊介绍: Optics Express is the all-electronic, open access journal for optics providing rapid publication for peer-reviewed articles that emphasize scientific and technology innovations in all aspects of optics and photonics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信