{"title":"评估新开发的可穿戴耳道温度计,模拟体育和劳动领域的活动应用。","authors":"Issei Kato, Hironori Watanabe, Kei Nagashima","doi":"10.1186/s12576-023-00874-4","DOIUrl":null,"url":null,"abstract":"<p><p>We evaluated the reliability of a newly developed wearable ear canal thermometer based on three different experiments, in which ear canal and rectal temperature (T<sub>ear</sub> and T<sub>rec</sub>, respectively) were simultaneously monitored. In Experiment 1, participants sat at 28 °C and 50% relative humidity (RH), during which fanning or 41 °C lower legs water immersion was conducted. In Experiment 2, participants conducted a 70-min treadmill exercise (4 km/h, 0.5% slope) at 35 °C and 50% RH with intermittent fanning. In Experiment 3, participants completed a 20 min treadmill exercise (6 km/h, 5% slope) at 35 °C and 65% RH. Bland-Altman analysis for T<sub>ear</sub> and T<sub>rec</sub> showed the difference of - 0.2-0.3 °C and the limit of agreement of the mean ± 0.3-0.6 °C. The intraclass correlation coefficient was 0.44-0.83. The results may suggest that the ear canal thermometer is useful to assess core body temperature in sports and/or labor fields.</p>","PeriodicalId":16832,"journal":{"name":"Journal of Physiological Sciences","volume":"73 1","pages":"15"},"PeriodicalIF":2.6000,"publicationDate":"2023-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10717959/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of newly developed wearable ear canal thermometer, mimicking the application to activities on sports and labor fields.\",\"authors\":\"Issei Kato, Hironori Watanabe, Kei Nagashima\",\"doi\":\"10.1186/s12576-023-00874-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We evaluated the reliability of a newly developed wearable ear canal thermometer based on three different experiments, in which ear canal and rectal temperature (T<sub>ear</sub> and T<sub>rec</sub>, respectively) were simultaneously monitored. In Experiment 1, participants sat at 28 °C and 50% relative humidity (RH), during which fanning or 41 °C lower legs water immersion was conducted. In Experiment 2, participants conducted a 70-min treadmill exercise (4 km/h, 0.5% slope) at 35 °C and 50% RH with intermittent fanning. In Experiment 3, participants completed a 20 min treadmill exercise (6 km/h, 5% slope) at 35 °C and 65% RH. Bland-Altman analysis for T<sub>ear</sub> and T<sub>rec</sub> showed the difference of - 0.2-0.3 °C and the limit of agreement of the mean ± 0.3-0.6 °C. The intraclass correlation coefficient was 0.44-0.83. The results may suggest that the ear canal thermometer is useful to assess core body temperature in sports and/or labor fields.</p>\",\"PeriodicalId\":16832,\"journal\":{\"name\":\"Journal of Physiological Sciences\",\"volume\":\"73 1\",\"pages\":\"15\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10717959/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Physiological Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12576-023-00874-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PHYSIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physiological Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12576-023-00874-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

我们通过三项不同的实验评估了新开发的可穿戴耳道温度计的可靠性,实验中同时监测了耳道温度和直肠温度(分别为 Tear 和 Trec)。在实验 1 中,参与者坐在 28 °C、相对湿度(RH)为 50%的环境中,在此期间进行扇扇子或 41 °C的小腿浸水。在实验 2 中,参与者在 35 °C、50% 相对湿度条件下进行 70 分钟的跑步机运动(4 公里/小时,0.5% 坡度),并间歇性地扇风。在实验 3 中,参与者在 35 °C 和 65% 相对湿度条件下进行了 20 分钟的跑步机运动(6 公里/小时,5% 坡度)。对 Tear 和 Trec 进行的 Bland-Altman 分析表明,两者的差异为 - 0.2-0.3 °C,平均值的一致性极限为 ± 0.3-0.6 °C。类内相关系数为 0.44-0.83。结果表明,耳道温度计可用于评估运动和/或劳动领域的核心体温。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of newly developed wearable ear canal thermometer, mimicking the application to activities on sports and labor fields.

We evaluated the reliability of a newly developed wearable ear canal thermometer based on three different experiments, in which ear canal and rectal temperature (Tear and Trec, respectively) were simultaneously monitored. In Experiment 1, participants sat at 28 °C and 50% relative humidity (RH), during which fanning or 41 °C lower legs water immersion was conducted. In Experiment 2, participants conducted a 70-min treadmill exercise (4 km/h, 0.5% slope) at 35 °C and 50% RH with intermittent fanning. In Experiment 3, participants completed a 20 min treadmill exercise (6 km/h, 5% slope) at 35 °C and 65% RH. Bland-Altman analysis for Tear and Trec showed the difference of - 0.2-0.3 °C and the limit of agreement of the mean ± 0.3-0.6 °C. The intraclass correlation coefficient was 0.44-0.83. The results may suggest that the ear canal thermometer is useful to assess core body temperature in sports and/or labor fields.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.40
自引率
4.30%
发文量
27
审稿时长
6-12 weeks
期刊介绍: The Journal of Physiological Sciences publishes peer-reviewed original papers, reviews, short communications, technical notes, and letters to the editor, based on the principles and theories of modern physiology and addressed to the international scientific community. All fields of physiology are covered, encompassing molecular, cellular and systems physiology. The emphasis is on human and vertebrate physiology, but comparative papers are also considered. The process of obtaining results must be ethically sound. Fields covered: Adaptation and environment Autonomic nervous function Biophysics Cell sensors and signaling Central nervous system and brain sciences Endocrinology and metabolism Excitable membranes and neural cell physiology Exercise physiology Gastrointestinal and kidney physiology Heart and circulatory physiology Molecular and cellular physiology Muscle physiology Physiome/systems biology Respiration physiology Senses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信