通过nageotte血细胞术和流式细胞术评估的白细胞减少的堆积红细胞单位质量的比较研究。

IF 0.6 Q4 HEMATOLOGY
Asian Journal of Transfusion Science Pub Date : 2023-01-01 Epub Date: 2022-09-28 DOI:10.4103/ajts.AJTS_101_21
Mohd Anas Sheikh, Amit Kumar Biswas, Ajay Kumar Baranwal, Neerja Kushwaha, Santosh Karade, Joseph Philip
{"title":"通过nageotte血细胞术和流式细胞术评估的白细胞减少的堆积红细胞单位质量的比较研究。","authors":"Mohd Anas Sheikh,&nbsp;Amit Kumar Biswas,&nbsp;Ajay Kumar Baranwal,&nbsp;Neerja Kushwaha,&nbsp;Santosh Karade,&nbsp;Joseph Philip","doi":"10.4103/ajts.AJTS_101_21","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units.</p><p><strong>Materials and methods: </strong>A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs.</p><p><strong>Results: </strong>The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R<sup>2</sup>= 0.098, <i>P</i> = 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods.</p><p><strong>Conclusion: </strong>Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs.</p>","PeriodicalId":42296,"journal":{"name":"Asian Journal of Transfusion Science","volume":"17 1","pages":"63-68"},"PeriodicalIF":0.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6d/54/AJTS-17-63.PMC10180788.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry.\",\"authors\":\"Mohd Anas Sheikh,&nbsp;Amit Kumar Biswas,&nbsp;Ajay Kumar Baranwal,&nbsp;Neerja Kushwaha,&nbsp;Santosh Karade,&nbsp;Joseph Philip\",\"doi\":\"10.4103/ajts.AJTS_101_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units.</p><p><strong>Materials and methods: </strong>A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs.</p><p><strong>Results: </strong>The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R<sup>2</sup>= 0.098, <i>P</i> = 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods.</p><p><strong>Conclusion: </strong>Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs.</p>\",\"PeriodicalId\":42296,\"journal\":{\"name\":\"Asian Journal of Transfusion Science\",\"volume\":\"17 1\",\"pages\":\"63-68\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6d/54/AJTS-17-63.PMC10180788.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Transfusion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ajts.AJTS_101_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/9/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Transfusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ajts.AJTS_101_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/28 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估残余白细胞(rWBC)计数对于确定白细胞贫化(LD)血液成分的质量至关重要。自动细胞分析仪缺乏对LD血液成分中发现的极少数白细胞进行评估的灵敏度。基于流式细胞术(FC)的方法和Nageotte血细胞仪是最常用的技术。本研究的目的是比较Nageotte血细胞仪和FC在LD红细胞单位质量控制中的应用。材料和方法:2018年9月至2020年9月,在一家三级护理中心的免疫血液学和输血科进行了一项前瞻性观察性研究。结果:流式细胞仪和Nageotte氏血细胞仪检测的rWBC数(平均值)分别为1.06±0.43白细胞/μL和0.67±0.39 WBC/μL。Nageotte血细胞仪法和FC法的变异系数分别为58.37%和40.46%。线性回归分析未显示任何相关性(R2=0.098,P=0.001),而Pearson相关系数显示两种方法之间的弱相关性(r=0.31)。结论:与Nageotte血细胞仪相比,流式细胞仪技术提供了一种更精确、更准确的客观工具,后者劳动密集、耗时,容易因主观性和低估偏差而产生错误。在缺乏足够的基础设施、资源和训练有素的劳动力的情况下,Nageotte血细胞仪方法是一种可靠的替代方法。Nageotte的小室可以最好地用于资源受限的设置,因为它提供了一种相对便宜、简单和可行的方法来枚举rWBC。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry.

Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry.

Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry.

Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry.

Purpose: Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units.

Materials and methods: A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs.

Results: The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R2= 0.098, P = 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods.

Conclusion: Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
56
审稿时长
44 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信