三维超声评估胎儿心脏主动脉瓣和肺动脉瓣环面积:参考曲线及其在先天性心脏病中的适用性。

IF 1.7 4区 医学 Q3 OBSTETRICS & GYNECOLOGY
Caroline Cervante Chagas, Ana Letícia Siqueira Pontes, Nathalie Jeanne Bravo-Valenzuela, Alberto Borges Peixoto, Ilenia Mappa, Clementina Viscardi, Giuseppe Rizzo, Edward Araujo Júnior
{"title":"三维超声评估胎儿心脏主动脉瓣和肺动脉瓣环面积:参考曲线及其在先天性心脏病中的适用性。","authors":"Caroline Cervante Chagas,&nbsp;Ana Letícia Siqueira Pontes,&nbsp;Nathalie Jeanne Bravo-Valenzuela,&nbsp;Alberto Borges Peixoto,&nbsp;Ilenia Mappa,&nbsp;Clementina Viscardi,&nbsp;Giuseppe Rizzo,&nbsp;Edward Araujo Júnior","doi":"10.1515/jpm-2022-0532","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To determine reference curves for fetal aortic and pulmonary valve annulus area by three-dimensional ultrasonography using the spatio-temporal image correlation (STIC) in the rendering mode, and to ascertain its applicability in congenital heart disease (CHD).</p><p><strong>Methods: </strong>We performed a retrospective cross-sectional study of 328 normal fetuses and 42 fetuses with CHD between 20 and 33 weeks 6 days of gestation. The outflow plane view of the great vessels was used to measure the areas of the valvar annuli, and the measurements were performed in systole. A linear regression model adjusted according to the determination coefficient (R<sup>2</sup>) was utilized to construct the reference intervals. The concordance correlation coefficient (CCC) was used to calculate the reproducibility of the mitral and tricuspid valve areas.</p><p><strong>Results: </strong>The mean ± standard deviation (SD) of the aortic and pulmonary valve annulus areas ranged from 6.6 ± 1.2 to 32.9 ± 1.1 mm<sup>2</sup> and 10.7 ± 1.3 to 40.3 ± 1.2 mm<sup>2</sup>, respectively. We observed a linear relationship and strong positive correlation between the area of the aortic and pulmonary valve annuli with r=0.97 and 0.96, respectively. Good intra (CCC=0.99) and interobserver agreement (CCC=0.98) was observed for the measurement of the aortic valve annulus area. A good intra (CCC=0.99) and interobserver (CCC=0.97) agreement was also observed for the measurement of the pulmonary valve annulus area. The mean ± SD of the difference of the areas of the aortic and pulmonary valve annuli between the normal fetuses and those with CHD were -1.801 ± 1.429 mm<sup>2</sup> (p=0.208) and -1.033 ± 1.467 mm<sup>2</sup> (p<0.0001), respectively.</p><p><strong>Conclusions: </strong>The reference curves for the areas of the aortic and pulmonary valve annuli of fetal hearts were determined, and showed good inter and intraobserver reproducibility. The constructed reference curves showed applicability in different types of CHD.</p>","PeriodicalId":16704,"journal":{"name":"Journal of Perinatal Medicine","volume":"51 6","pages":"805-814"},"PeriodicalIF":1.7000,"publicationDate":"2023-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of fetal heart aortic and pulmonary valve annulus area by three-dimensional ultrasonography: reference curves and applicability in congenital heart diseases.\",\"authors\":\"Caroline Cervante Chagas,&nbsp;Ana Letícia Siqueira Pontes,&nbsp;Nathalie Jeanne Bravo-Valenzuela,&nbsp;Alberto Borges Peixoto,&nbsp;Ilenia Mappa,&nbsp;Clementina Viscardi,&nbsp;Giuseppe Rizzo,&nbsp;Edward Araujo Júnior\",\"doi\":\"10.1515/jpm-2022-0532\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To determine reference curves for fetal aortic and pulmonary valve annulus area by three-dimensional ultrasonography using the spatio-temporal image correlation (STIC) in the rendering mode, and to ascertain its applicability in congenital heart disease (CHD).</p><p><strong>Methods: </strong>We performed a retrospective cross-sectional study of 328 normal fetuses and 42 fetuses with CHD between 20 and 33 weeks 6 days of gestation. The outflow plane view of the great vessels was used to measure the areas of the valvar annuli, and the measurements were performed in systole. A linear regression model adjusted according to the determination coefficient (R<sup>2</sup>) was utilized to construct the reference intervals. The concordance correlation coefficient (CCC) was used to calculate the reproducibility of the mitral and tricuspid valve areas.</p><p><strong>Results: </strong>The mean ± standard deviation (SD) of the aortic and pulmonary valve annulus areas ranged from 6.6 ± 1.2 to 32.9 ± 1.1 mm<sup>2</sup> and 10.7 ± 1.3 to 40.3 ± 1.2 mm<sup>2</sup>, respectively. We observed a linear relationship and strong positive correlation between the area of the aortic and pulmonary valve annuli with r=0.97 and 0.96, respectively. Good intra (CCC=0.99) and interobserver agreement (CCC=0.98) was observed for the measurement of the aortic valve annulus area. A good intra (CCC=0.99) and interobserver (CCC=0.97) agreement was also observed for the measurement of the pulmonary valve annulus area. The mean ± SD of the difference of the areas of the aortic and pulmonary valve annuli between the normal fetuses and those with CHD were -1.801 ± 1.429 mm<sup>2</sup> (p=0.208) and -1.033 ± 1.467 mm<sup>2</sup> (p<0.0001), respectively.</p><p><strong>Conclusions: </strong>The reference curves for the areas of the aortic and pulmonary valve annuli of fetal hearts were determined, and showed good inter and intraobserver reproducibility. The constructed reference curves showed applicability in different types of CHD.</p>\",\"PeriodicalId\":16704,\"journal\":{\"name\":\"Journal of Perinatal Medicine\",\"volume\":\"51 6\",\"pages\":\"805-814\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Perinatal Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/jpm-2022-0532\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Perinatal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/jpm-2022-0532","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:利用时空图像相关(STIC)绘制模式确定胎儿主动脉、肺动脉瓣环面积的三维超声参考曲线,并探讨其在先天性心脏病(CHD)诊断中的适用性。方法:我们对328例正常胎儿和42例妊娠20 ~ 33周6天的冠心病胎儿进行了回顾性横断面研究。大血管的流出面视图用于测量瓣膜环空的面积,测量是在收缩期进行的。采用根据决定系数(R2)调整的线性回归模型构建参考区间。一致性相关系数(CCC)用于计算二尖瓣和三尖瓣面积的再现性。结果:主动脉瓣和肺动脉瓣环面积的平均±标准差(SD)分别为6.6±1.2 ~ 32.9±1.1 mm2和10.7±1.3 ~ 40.3±1.2 mm2。我们观察到主动脉瓣和肺动脉瓣环面积呈线性关系,且呈强正相关,r分别为0.97和0.96。对于主动脉瓣环面积的测量,观察组内(CCC=0.99)和观察组间(CCC=0.98)的一致性良好。在测量肺动脉瓣环面积时,观察组内(CCC=0.99)和观察组间(CCC=0.97)的一致性也很好。正常胎儿与冠心病胎儿主动脉瓣和肺动脉瓣环面积差异的平均值±SD分别为-1.801±1.429 mm2 (p=0.208)和-1.033±1.467 mm2 (p < 0.05)。结论:确定了胎儿心脏主动脉瓣和肺动脉瓣环面积的参考曲线,具有良好的观察间和观察内重复性。所构建的参考曲线适用于不同类型的冠心病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of fetal heart aortic and pulmonary valve annulus area by three-dimensional ultrasonography: reference curves and applicability in congenital heart diseases.

Objectives: To determine reference curves for fetal aortic and pulmonary valve annulus area by three-dimensional ultrasonography using the spatio-temporal image correlation (STIC) in the rendering mode, and to ascertain its applicability in congenital heart disease (CHD).

Methods: We performed a retrospective cross-sectional study of 328 normal fetuses and 42 fetuses with CHD between 20 and 33 weeks 6 days of gestation. The outflow plane view of the great vessels was used to measure the areas of the valvar annuli, and the measurements were performed in systole. A linear regression model adjusted according to the determination coefficient (R2) was utilized to construct the reference intervals. The concordance correlation coefficient (CCC) was used to calculate the reproducibility of the mitral and tricuspid valve areas.

Results: The mean ± standard deviation (SD) of the aortic and pulmonary valve annulus areas ranged from 6.6 ± 1.2 to 32.9 ± 1.1 mm2 and 10.7 ± 1.3 to 40.3 ± 1.2 mm2, respectively. We observed a linear relationship and strong positive correlation between the area of the aortic and pulmonary valve annuli with r=0.97 and 0.96, respectively. Good intra (CCC=0.99) and interobserver agreement (CCC=0.98) was observed for the measurement of the aortic valve annulus area. A good intra (CCC=0.99) and interobserver (CCC=0.97) agreement was also observed for the measurement of the pulmonary valve annulus area. The mean ± SD of the difference of the areas of the aortic and pulmonary valve annuli between the normal fetuses and those with CHD were -1.801 ± 1.429 mm2 (p=0.208) and -1.033 ± 1.467 mm2 (p<0.0001), respectively.

Conclusions: The reference curves for the areas of the aortic and pulmonary valve annuli of fetal hearts were determined, and showed good inter and intraobserver reproducibility. The constructed reference curves showed applicability in different types of CHD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Perinatal Medicine
Journal of Perinatal Medicine 医学-妇产科学
CiteScore
4.40
自引率
8.30%
发文量
183
审稿时长
4-8 weeks
期刊介绍: The Journal of Perinatal Medicine (JPM) is a truly international forum covering the entire field of perinatal medicine. It is an essential news source for all those obstetricians, neonatologists, perinatologists and allied health professionals who wish to keep abreast of progress in perinatal and related research. Ahead-of-print publishing ensures fastest possible knowledge transfer. The Journal provides statements on themes of topical interest as well as information and different views on controversial topics. It also informs about the academic, organisational and political aims and objectives of the World Association of Perinatal Medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信