新型冠状病毒肺炎大流行期间气管插管气雾剂盒性能的系统评价

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
R Ajay Christopher, Aparna Lohanathan, Darpanarayan Hazra, Rathijit Pal, Vaishnavi Vegiraju, Kundavaram Paul Prabhakar Abhilash
{"title":"新型冠状病毒肺炎大流行期间气管插管气雾剂盒性能的系统评价","authors":"R Ajay Christopher,&nbsp;Aparna Lohanathan,&nbsp;Darpanarayan Hazra,&nbsp;Rathijit Pal,&nbsp;Vaishnavi Vegiraju,&nbsp;Kundavaram Paul Prabhakar Abhilash","doi":"10.4103/jgid.jgid_165_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In the backdrop of the COVID-19 pandemic, endotracheal intubation using an aerosol box (AB) became the norm in the emergency department (ED) and the intensive care unit. We compared two models of AB with different dimensions to compare and identify a device that helps in reducing viral exposure without compromising successful airway management.</p><p><strong>Methods: </strong>We conducted this prospective observational study for 7 months (October 20-April 21) on 143 patients presenting with an acute airway compromise to the ED. All intubations were performed using one of the two models available. The primary outcome was time taken for intubation (TTI).</p><p><strong>Results: </strong>The overall median time taken to intubate using any AB was 63 (interquartile range [IQR]: 46.2-87.7) s with an 81.9% first-pass success (FPS) rate. TTI for AB I was 67 (IQR: 53-106) s with a 76.3% FPS rate, while TTI for AB II was 57 (IQR: 44-75) s with an 85.9% FPS rate. TTI was much shorter without the use of an AB (34: IQR: 24-53 s) with a 92% FPS rate. Intubations done by emergency physicians with more than 2 years of experience were faster in both with or without AB when compared to intubations done by physicians with <2 years of experience.</p><p><strong>Conclusion: </strong>The use of an AB is associated with a longer TTI when compared to intubations done without an AB. TTI was relatively shorter when more experienced emergency physicians performed intubation. FPS rates were low with intubations done using AB.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/24/41/JGID-15-6.PMC10118207.pdf","citationCount":"0","resultStr":"{\"title\":\"Performance of Aerosol Boxes for Endotracheal Intubation during the COVID-19 Pandemic with Systematic Review.\",\"authors\":\"R Ajay Christopher,&nbsp;Aparna Lohanathan,&nbsp;Darpanarayan Hazra,&nbsp;Rathijit Pal,&nbsp;Vaishnavi Vegiraju,&nbsp;Kundavaram Paul Prabhakar Abhilash\",\"doi\":\"10.4103/jgid.jgid_165_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>In the backdrop of the COVID-19 pandemic, endotracheal intubation using an aerosol box (AB) became the norm in the emergency department (ED) and the intensive care unit. We compared two models of AB with different dimensions to compare and identify a device that helps in reducing viral exposure without compromising successful airway management.</p><p><strong>Methods: </strong>We conducted this prospective observational study for 7 months (October 20-April 21) on 143 patients presenting with an acute airway compromise to the ED. All intubations were performed using one of the two models available. The primary outcome was time taken for intubation (TTI).</p><p><strong>Results: </strong>The overall median time taken to intubate using any AB was 63 (interquartile range [IQR]: 46.2-87.7) s with an 81.9% first-pass success (FPS) rate. TTI for AB I was 67 (IQR: 53-106) s with a 76.3% FPS rate, while TTI for AB II was 57 (IQR: 44-75) s with an 85.9% FPS rate. TTI was much shorter without the use of an AB (34: IQR: 24-53 s) with a 92% FPS rate. Intubations done by emergency physicians with more than 2 years of experience were faster in both with or without AB when compared to intubations done by physicians with <2 years of experience.</p><p><strong>Conclusion: </strong>The use of an AB is associated with a longer TTI when compared to intubations done without an AB. TTI was relatively shorter when more experienced emergency physicians performed intubation. FPS rates were low with intubations done using AB.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/24/41/JGID-15-6.PMC10118207.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jgid.jgid_165_22\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jgid.jgid_165_22","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

在2019冠状病毒病大流行的背景下,使用气溶胶盒(AB)进行气管插管已成为急诊科(ED)和重症监护病房的常态。我们比较了两种不同尺寸的AB模型,以比较和确定一种有助于减少病毒暴露而不影响成功气道管理的设备。方法:我们对143例急症患者进行了为期7个月(10月20日至4月21日)的前瞻性观察性研究。所有患者均使用两种可用模型中的一种进行插管。主要观察指标为插管时间(TTI)。结果:使用任何AB插管所需的总中位时间为63(四分位数间距[IQR]: 46.2-87.7) s,首次通过成功率(FPS)为81.9%。AB I的TTI为67 (IQR: 53-106) s, FPS率为76.3%;AB II的TTI为57 (IQR: 44-75) s, FPS率为85.9%。在不使用AB的情况下,TTI要短得多(34:IQR: 24-53秒),FPS率为92%。结论:与没有AB的插管相比,使用AB与TTI时间较长相关。当经验丰富的急诊医生进行插管时,TTI时间相对较短。使用AB插管时,FPS率较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Performance of Aerosol Boxes for Endotracheal Intubation during the COVID-19 Pandemic with Systematic Review.

Performance of Aerosol Boxes for Endotracheal Intubation during the COVID-19 Pandemic with Systematic Review.

Performance of Aerosol Boxes for Endotracheal Intubation during the COVID-19 Pandemic with Systematic Review.

Performance of Aerosol Boxes for Endotracheal Intubation during the COVID-19 Pandemic with Systematic Review.

Introduction: In the backdrop of the COVID-19 pandemic, endotracheal intubation using an aerosol box (AB) became the norm in the emergency department (ED) and the intensive care unit. We compared two models of AB with different dimensions to compare and identify a device that helps in reducing viral exposure without compromising successful airway management.

Methods: We conducted this prospective observational study for 7 months (October 20-April 21) on 143 patients presenting with an acute airway compromise to the ED. All intubations were performed using one of the two models available. The primary outcome was time taken for intubation (TTI).

Results: The overall median time taken to intubate using any AB was 63 (interquartile range [IQR]: 46.2-87.7) s with an 81.9% first-pass success (FPS) rate. TTI for AB I was 67 (IQR: 53-106) s with a 76.3% FPS rate, while TTI for AB II was 57 (IQR: 44-75) s with an 85.9% FPS rate. TTI was much shorter without the use of an AB (34: IQR: 24-53 s) with a 92% FPS rate. Intubations done by emergency physicians with more than 2 years of experience were faster in both with or without AB when compared to intubations done by physicians with <2 years of experience.

Conclusion: The use of an AB is associated with a longer TTI when compared to intubations done without an AB. TTI was relatively shorter when more experienced emergency physicians performed intubation. FPS rates were low with intubations done using AB.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信