交叉偏振光学相干断层扫描技术用于评估寻常型硬化性地衣皮肤病变程度的临床研究。

IF 1.1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Sovremennye Tehnologii v Medicine Pub Date : 2023-01-01 Epub Date: 2023-01-28 DOI:10.17691/stm2023.15.1.06
A L Potapov, M M Loginova, A A Moiseev, S G Radenska-Lopovok, S S Kuznetsov, I A Kuznetsova, N N Mustafina, I K Safonov, N D Gladkova, M A Sirotkina
{"title":"交叉偏振光学相干断层扫描技术用于评估寻常型硬化性地衣皮肤病变程度的临床研究。","authors":"A L Potapov, M M Loginova, A A Moiseev, S G Radenska-Lopovok, S S Kuznetsov, I A Kuznetsova, N N Mustafina, I K Safonov, N D Gladkova, M A Sirotkina","doi":"10.17691/stm2023.15.1.06","DOIUrl":null,"url":null,"abstract":"<p><p><b>The aim of the study</b> was to identify different degrees of dermal lesions in vulvar lichen sclerosus (VLS) using cross-polarization optical coherence tomography (CP OCT) based on attenuation coefficient to detect disease early manifestations and to monitor the effectiveness of treatment.</p><p><strong>Materials and methods: </strong>The study included 10 patients without pathology and 39 patients with VLS diagnosed histologically. CP OCT was performed <i>in vivo</i> on the inner surface of the labia minora, in the main lesion area. From each scanning point, a 3.4×3.4×1.25-mm3 3D data array was obtained in 26 s. CP OCT examination results were compared with histological examination of specimens stained with Van Gieson's picrofuchsin.Quantitative analysis of OCT images was performed by measuring the attenuation coefficient in co-polarization and cross-polarization. For visual analysis, color-coded charts were developed based on OCT attenuation coefficients.</p><p><strong>Results: </strong>According to histological examination, all patients with VLS were divided into 4 groups as per dermal lesion degree: initial (8 patients); mild (7 patients); moderate (9 patients); severe (15 patients). Typical features of different degrees were interfibrillary edema up to 250 μm deep for initial degree, thickened collagen bundles without edema up to 350 μm deep for mild degree, dermis homogenization up to 700 μm deep for moderate degree, dermis homogenization and total edema up to 1200 μm deep for severe degree.Pathological processes in dermis during VLS like interfibrillary edema and collagen bundles homogenization were visualized using CP OCT method based on values of attenuation coefficient in co- and cross-polarization channels. However, CP OCT method appeared to be less sensitive to changes of collagen bundles thickness not allowing to distinguish thickened collagen bundles from normal ones with enough statistical significance. The CP OCT method was able to differentiate all degrees of dermal lesions among themselves. OCT attenuation coefficients differed from normal condition with statistical significance for all degrees of lesions, except for mild.</p><p><strong>Conclusion: </strong>For the first time, quantitative parameters for each degrees of dermis lesion in VLS, including initial degree, were determined by CP OCT method allowing to detect the disease at an early stage and to monitor the applied clinical treatment effectiveness.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10306962/pdf/","citationCount":"0","resultStr":"{\"title\":\"Cross-Polarization Optical Coherence Tomography for Clinical Evaluation of Dermal Lesion Degrees in Vulvar Lichen Sclerosus.\",\"authors\":\"A L Potapov, M M Loginova, A A Moiseev, S G Radenska-Lopovok, S S Kuznetsov, I A Kuznetsova, N N Mustafina, I K Safonov, N D Gladkova, M A Sirotkina\",\"doi\":\"10.17691/stm2023.15.1.06\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>The aim of the study</b> was to identify different degrees of dermal lesions in vulvar lichen sclerosus (VLS) using cross-polarization optical coherence tomography (CP OCT) based on attenuation coefficient to detect disease early manifestations and to monitor the effectiveness of treatment.</p><p><strong>Materials and methods: </strong>The study included 10 patients without pathology and 39 patients with VLS diagnosed histologically. CP OCT was performed <i>in vivo</i> on the inner surface of the labia minora, in the main lesion area. From each scanning point, a 3.4×3.4×1.25-mm3 3D data array was obtained in 26 s. CP OCT examination results were compared with histological examination of specimens stained with Van Gieson's picrofuchsin.Quantitative analysis of OCT images was performed by measuring the attenuation coefficient in co-polarization and cross-polarization. For visual analysis, color-coded charts were developed based on OCT attenuation coefficients.</p><p><strong>Results: </strong>According to histological examination, all patients with VLS were divided into 4 groups as per dermal lesion degree: initial (8 patients); mild (7 patients); moderate (9 patients); severe (15 patients). Typical features of different degrees were interfibrillary edema up to 250 μm deep for initial degree, thickened collagen bundles without edema up to 350 μm deep for mild degree, dermis homogenization up to 700 μm deep for moderate degree, dermis homogenization and total edema up to 1200 μm deep for severe degree.Pathological processes in dermis during VLS like interfibrillary edema and collagen bundles homogenization were visualized using CP OCT method based on values of attenuation coefficient in co- and cross-polarization channels. However, CP OCT method appeared to be less sensitive to changes of collagen bundles thickness not allowing to distinguish thickened collagen bundles from normal ones with enough statistical significance. The CP OCT method was able to differentiate all degrees of dermal lesions among themselves. OCT attenuation coefficients differed from normal condition with statistical significance for all degrees of lesions, except for mild.</p><p><strong>Conclusion: </strong>For the first time, quantitative parameters for each degrees of dermis lesion in VLS, including initial degree, were determined by CP OCT method allowing to detect the disease at an early stage and to monitor the applied clinical treatment effectiveness.</p>\",\"PeriodicalId\":51886,\"journal\":{\"name\":\"Sovremennye Tehnologii v Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10306962/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sovremennye Tehnologii v Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17691/stm2023.15.1.06\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sovremennye Tehnologii v Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17691/stm2023.15.1.06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/28 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是使用基于衰减系数的交叉偏振光学相干断层扫描(CP OCT)来识别外阴硬化性苔藓(VLS)中不同程度的真皮病变,以检测疾病的早期表现并监测治疗的有效性。材料和方法:本研究包括10例无病理的患者和39例经组织学诊断的VLS患者。在主要病变区域的小阴唇内表面进行体内CP OCT。从每个扫描点,在26秒内获得3.4×3.4×1.25-mm3的3D数据阵列。将CP OCT检查结果与用Van Gieson's picrofuchsin染色的标本的组织学检查进行比较。通过测量共极化和交叉极化中的衰减系数对OCT图像进行定量分析。为了进行视觉分析,根据OCT衰减系数编制了彩色编码图表。结果:根据组织学检查,所有VLS患者按真皮病变程度分为4组:首发(8例);轻度(7例);中度(9例);严重(15例)。不同程度的典型特征是初始深度达250μm的纤维间水肿,轻度深度达350μm的无水肿增厚胶原束,中度深度达700μm的真皮均质化,重度深度达1200μm的完全水肿。基于共极化和交叉极化通道中的衰减系数值,使用CP OCT方法对VLS样纤维间水肿和胶原束均匀化过程中真皮的病理过程进行可视化。然而,CP OCT方法似乎对胶原束厚度的变化不太敏感,无法将增厚的胶原束与正常胶原束区分开来,具有足够的统计学意义。CP OCT方法能够区分不同程度的真皮损伤。OCT衰减系数与正常情况不同,除轻度病变外,所有程度的病变均有统计学意义。结论:首次通过CP OCT方法确定了VLS中真皮病变的各个程度的定量参数,包括初始程度,从而在早期发现疾病并监测应用的临床治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Cross-Polarization Optical Coherence Tomography for Clinical Evaluation of Dermal Lesion Degrees in Vulvar Lichen Sclerosus.

Cross-Polarization Optical Coherence Tomography for Clinical Evaluation of Dermal Lesion Degrees in Vulvar Lichen Sclerosus.

Cross-Polarization Optical Coherence Tomography for Clinical Evaluation of Dermal Lesion Degrees in Vulvar Lichen Sclerosus.

Cross-Polarization Optical Coherence Tomography for Clinical Evaluation of Dermal Lesion Degrees in Vulvar Lichen Sclerosus.

The aim of the study was to identify different degrees of dermal lesions in vulvar lichen sclerosus (VLS) using cross-polarization optical coherence tomography (CP OCT) based on attenuation coefficient to detect disease early manifestations and to monitor the effectiveness of treatment.

Materials and methods: The study included 10 patients without pathology and 39 patients with VLS diagnosed histologically. CP OCT was performed in vivo on the inner surface of the labia minora, in the main lesion area. From each scanning point, a 3.4×3.4×1.25-mm3 3D data array was obtained in 26 s. CP OCT examination results were compared with histological examination of specimens stained with Van Gieson's picrofuchsin.Quantitative analysis of OCT images was performed by measuring the attenuation coefficient in co-polarization and cross-polarization. For visual analysis, color-coded charts were developed based on OCT attenuation coefficients.

Results: According to histological examination, all patients with VLS were divided into 4 groups as per dermal lesion degree: initial (8 patients); mild (7 patients); moderate (9 patients); severe (15 patients). Typical features of different degrees were interfibrillary edema up to 250 μm deep for initial degree, thickened collagen bundles without edema up to 350 μm deep for mild degree, dermis homogenization up to 700 μm deep for moderate degree, dermis homogenization and total edema up to 1200 μm deep for severe degree.Pathological processes in dermis during VLS like interfibrillary edema and collagen bundles homogenization were visualized using CP OCT method based on values of attenuation coefficient in co- and cross-polarization channels. However, CP OCT method appeared to be less sensitive to changes of collagen bundles thickness not allowing to distinguish thickened collagen bundles from normal ones with enough statistical significance. The CP OCT method was able to differentiate all degrees of dermal lesions among themselves. OCT attenuation coefficients differed from normal condition with statistical significance for all degrees of lesions, except for mild.

Conclusion: For the first time, quantitative parameters for each degrees of dermis lesion in VLS, including initial degree, were determined by CP OCT method allowing to detect the disease at an early stage and to monitor the applied clinical treatment effectiveness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sovremennye Tehnologii v Medicine
Sovremennye Tehnologii v Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.80
自引率
0.00%
发文量
38
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信