左心室辅助装置患者的夜间睡眠和白天嗜睡模式。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2024-06-01 Epub Date: 2023-06-30 DOI:10.1007/s10047-023-01410-2
Umar A Siddiqi, Aashka Patel, Yena Jang, Jennifer Cruz, Pamela Combs, Jesus M Casida
{"title":"左心室辅助装置患者的夜间睡眠和白天嗜睡模式。","authors":"Umar A Siddiqi, Aashka Patel, Yena Jang, Jennifer Cruz, Pamela Combs, Jesus M Casida","doi":"10.1007/s10047-023-01410-2","DOIUrl":null,"url":null,"abstract":"<p><p>Despite the high prevalence of sleep disturbance in the heart failure population, information about its consequence on daytime function in patients with left-ventricular assist devices (LVADs) is limited. This study examined the nighttime and daytime sleep patterns and changes from pre-implant to 6 months post-implant. This study included 32 LVAD patients. Demographics, nighttime and daytime sleep variables were collected pre-implant and at 1, 3, and 6 months post-implant. Wrist actigraphy and self-report questionnaires measured objective and subjective sleep, respectively. Objective nighttime sleep data were sleep efficiency (SE), sleep latency (SL), total sleep time (TST), wake after sleep onset (WASO), and sleep fragmentation (SF). Objective daytime sleep data were nap times. Self-reported Subjective Sleep Quality Scale (SSQS) and Stanford Sleepiness Scale (SSS) were subjective measures. Increased SF and WASO scores and decreased TST and SE scores were found pre-LVAD implant, indicative of poor sleep quality. TST, SE, naptime and SSQS scores were higher at 3 and 6 months post-implant compared to baseline. Decreases in TST and SF scores were observed at 3 and 6 months post-implant along with increases in SSS scores. Increasing SSS scores and decreasing overall scores from pre- and up to 6 months post-implant suggest improvement in daytime function. This study provides information on sleep-daytime function in the LVAD patient population. Improvements in daytime sleepiness do not imply \"good\" sleep quality, consistent with the extant knowledge in LVAD literature. Future investigations should elucidate the mechanism by which sleep-daytime function influences quality of life.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nighttime sleep and daytime sleepiness patterns among left ventricular assist device patients.\",\"authors\":\"Umar A Siddiqi, Aashka Patel, Yena Jang, Jennifer Cruz, Pamela Combs, Jesus M Casida\",\"doi\":\"10.1007/s10047-023-01410-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Despite the high prevalence of sleep disturbance in the heart failure population, information about its consequence on daytime function in patients with left-ventricular assist devices (LVADs) is limited. This study examined the nighttime and daytime sleep patterns and changes from pre-implant to 6 months post-implant. This study included 32 LVAD patients. Demographics, nighttime and daytime sleep variables were collected pre-implant and at 1, 3, and 6 months post-implant. Wrist actigraphy and self-report questionnaires measured objective and subjective sleep, respectively. Objective nighttime sleep data were sleep efficiency (SE), sleep latency (SL), total sleep time (TST), wake after sleep onset (WASO), and sleep fragmentation (SF). Objective daytime sleep data were nap times. Self-reported Subjective Sleep Quality Scale (SSQS) and Stanford Sleepiness Scale (SSS) were subjective measures. Increased SF and WASO scores and decreased TST and SE scores were found pre-LVAD implant, indicative of poor sleep quality. TST, SE, naptime and SSQS scores were higher at 3 and 6 months post-implant compared to baseline. Decreases in TST and SF scores were observed at 3 and 6 months post-implant along with increases in SSS scores. Increasing SSS scores and decreasing overall scores from pre- and up to 6 months post-implant suggest improvement in daytime function. This study provides information on sleep-daytime function in the LVAD patient population. Improvements in daytime sleepiness do not imply \\\"good\\\" sleep quality, consistent with the extant knowledge in LVAD literature. Future investigations should elucidate the mechanism by which sleep-daytime function influences quality of life.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10047-023-01410-2\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01410-2","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/30 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

尽管睡眠障碍在心力衰竭人群中发病率很高,但有关其对左心室辅助装置(LVAD)患者日间功能影响的信息却很有限。本研究调查了左心室辅助装置植入前至植入后 6 个月期间的夜间和白天睡眠模式及其变化。这项研究包括 32 名 LVAD 患者。研究人员收集了植入前以及植入后 1、3 和 6 个月的人口统计学数据、夜间和白天睡眠变量。腕动仪和自我报告问卷分别测量客观和主观睡眠。客观夜间睡眠数据包括睡眠效率(SE)、睡眠潜伏期(SL)、总睡眠时间(TST)、睡眠开始后唤醒(WASO)和睡眠片段(SF)。白天的客观睡眠数据为午睡时间。自我报告的主观睡眠质量量表(SSQS)和斯坦福嗜睡量表(SSS)是主观测量指标。在植入 LVAD 前,SF 和 WASO 分数增加,TST 和 SE 分数减少,表明睡眠质量不佳。与基线相比,植入手术后 3 个月和 6 个月的 TST、SE、午睡时间和 SSQS 得分更高。在植入手术后 3 个月和 6 个月,TST 和 SF 分数下降,SSS 分数上升。从植入前到植入后 6 个月,SSS 分数不断增加,总分不断下降,这表明患者的日间功能得到了改善。这项研究提供了有关 LVAD 患者日间睡眠功能的信息。白天嗜睡的改善并不意味着睡眠质量 "良好",这与 LVAD 文献中的现有知识一致。未来的研究应阐明睡眠-白天功能影响生活质量的机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Nighttime sleep and daytime sleepiness patterns among left ventricular assist device patients.

Despite the high prevalence of sleep disturbance in the heart failure population, information about its consequence on daytime function in patients with left-ventricular assist devices (LVADs) is limited. This study examined the nighttime and daytime sleep patterns and changes from pre-implant to 6 months post-implant. This study included 32 LVAD patients. Demographics, nighttime and daytime sleep variables were collected pre-implant and at 1, 3, and 6 months post-implant. Wrist actigraphy and self-report questionnaires measured objective and subjective sleep, respectively. Objective nighttime sleep data were sleep efficiency (SE), sleep latency (SL), total sleep time (TST), wake after sleep onset (WASO), and sleep fragmentation (SF). Objective daytime sleep data were nap times. Self-reported Subjective Sleep Quality Scale (SSQS) and Stanford Sleepiness Scale (SSS) were subjective measures. Increased SF and WASO scores and decreased TST and SE scores were found pre-LVAD implant, indicative of poor sleep quality. TST, SE, naptime and SSQS scores were higher at 3 and 6 months post-implant compared to baseline. Decreases in TST and SF scores were observed at 3 and 6 months post-implant along with increases in SSS scores. Increasing SSS scores and decreasing overall scores from pre- and up to 6 months post-implant suggest improvement in daytime function. This study provides information on sleep-daytime function in the LVAD patient population. Improvements in daytime sleepiness do not imply "good" sleep quality, consistent with the extant knowledge in LVAD literature. Future investigations should elucidate the mechanism by which sleep-daytime function influences quality of life.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信