Jennifer S Polus, Edward M Vasarhelyi, Brent A Lanting, Matthew G Teeter
{"title":"初级全髋关节置换术后使用和不使用螺钉固定髋臼杯:通过放射立体分析评估迁移情况。","authors":"Jennifer S Polus, Edward M Vasarhelyi, Brent A Lanting, Matthew G Teeter","doi":"10.1177/11207000231164711","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Early cup migration after total hip arthroplasty (THA) is correlated to late revision due to aseptic loosening. However, the use of screws for increased cup stability remains unclear and debated. The purpose of this study is to assess acetabular migration between cups fixated with and without the use of screws.</p><p><strong>Methods: </strong>Patients underwent primary THA using either a direct anterior (DA) or a direct lateral (DL) approach. The DA surgeon routinely supplemented cup fixation with 1 or 2 screws while the DL surgeon used no screws. At 7 follow-up visits up to 2 years post operation, patients underwent radiostereometric analysis (RSA) imaging for implant migration tracking. The primary outcome was defined as proximal cup migration measured with model-based RSA.</p><p><strong>Results: </strong>68 patients were assessed up to 2 years post operation, <i>n</i> = 43 received screws and <i>n</i> = 25 did not. The use of screws had a significant effect on cup migration (<i>p</i> = 0.018). From 2 weeks to 2 years post operation, the total mean migration was 0.403 ± 0.681 mm and 0.129 ± 0.272 mm (<i>p</i> = 0.319) for cups with and without screws, respectively. The number of screws used also had a significant impact, with cups fixated with 1 screw migrating more than cups fixated with 2 (<i>p</i> = 0.013, mean difference 0.712 mm).</p><p><strong>Conclusions: </strong>Acetabular cups fixated with only 1 screw resulted in greater migration than cups with no screws or 2 screws, though the mean magnitude was well under the 1.0 mm threshold for unacceptable migration. However, 3 of the 24 patients who received only 1 screw exceeded the 1.0 mm threshold for unacceptable migration. Ultimately, the results of this study show that the use of 2 screws to supplement cup fixation can provide good implant stability that is equivalent to a secure press-fit component with no screws.Clinical trial registration: ClinicalTrials.gov (NCT03558217).</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10787387/pdf/","citationCount":"0","resultStr":"{\"title\":\"Acetabular cup fixation with and without screws following primary total hip arthroplasty: migration evaluated by radiostereometric analysis.\",\"authors\":\"Jennifer S Polus, Edward M Vasarhelyi, Brent A Lanting, Matthew G Teeter\",\"doi\":\"10.1177/11207000231164711\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Early cup migration after total hip arthroplasty (THA) is correlated to late revision due to aseptic loosening. However, the use of screws for increased cup stability remains unclear and debated. The purpose of this study is to assess acetabular migration between cups fixated with and without the use of screws.</p><p><strong>Methods: </strong>Patients underwent primary THA using either a direct anterior (DA) or a direct lateral (DL) approach. The DA surgeon routinely supplemented cup fixation with 1 or 2 screws while the DL surgeon used no screws. At 7 follow-up visits up to 2 years post operation, patients underwent radiostereometric analysis (RSA) imaging for implant migration tracking. The primary outcome was defined as proximal cup migration measured with model-based RSA.</p><p><strong>Results: </strong>68 patients were assessed up to 2 years post operation, <i>n</i> = 43 received screws and <i>n</i> = 25 did not. The use of screws had a significant effect on cup migration (<i>p</i> = 0.018). From 2 weeks to 2 years post operation, the total mean migration was 0.403 ± 0.681 mm and 0.129 ± 0.272 mm (<i>p</i> = 0.319) for cups with and without screws, respectively. The number of screws used also had a significant impact, with cups fixated with 1 screw migrating more than cups fixated with 2 (<i>p</i> = 0.013, mean difference 0.712 mm).</p><p><strong>Conclusions: </strong>Acetabular cups fixated with only 1 screw resulted in greater migration than cups with no screws or 2 screws, though the mean magnitude was well under the 1.0 mm threshold for unacceptable migration. However, 3 of the 24 patients who received only 1 screw exceeded the 1.0 mm threshold for unacceptable migration. Ultimately, the results of this study show that the use of 2 screws to supplement cup fixation can provide good implant stability that is equivalent to a secure press-fit component with no screws.Clinical trial registration: ClinicalTrials.gov (NCT03558217).</p>\",\"PeriodicalId\":12911,\"journal\":{\"name\":\"HIP International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10787387/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HIP International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11207000231164711\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/4/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000231164711","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Acetabular cup fixation with and without screws following primary total hip arthroplasty: migration evaluated by radiostereometric analysis.
Background: Early cup migration after total hip arthroplasty (THA) is correlated to late revision due to aseptic loosening. However, the use of screws for increased cup stability remains unclear and debated. The purpose of this study is to assess acetabular migration between cups fixated with and without the use of screws.
Methods: Patients underwent primary THA using either a direct anterior (DA) or a direct lateral (DL) approach. The DA surgeon routinely supplemented cup fixation with 1 or 2 screws while the DL surgeon used no screws. At 7 follow-up visits up to 2 years post operation, patients underwent radiostereometric analysis (RSA) imaging for implant migration tracking. The primary outcome was defined as proximal cup migration measured with model-based RSA.
Results: 68 patients were assessed up to 2 years post operation, n = 43 received screws and n = 25 did not. The use of screws had a significant effect on cup migration (p = 0.018). From 2 weeks to 2 years post operation, the total mean migration was 0.403 ± 0.681 mm and 0.129 ± 0.272 mm (p = 0.319) for cups with and without screws, respectively. The number of screws used also had a significant impact, with cups fixated with 1 screw migrating more than cups fixated with 2 (p = 0.013, mean difference 0.712 mm).
Conclusions: Acetabular cups fixated with only 1 screw resulted in greater migration than cups with no screws or 2 screws, though the mean magnitude was well under the 1.0 mm threshold for unacceptable migration. However, 3 of the 24 patients who received only 1 screw exceeded the 1.0 mm threshold for unacceptable migration. Ultimately, the results of this study show that the use of 2 screws to supplement cup fixation can provide good implant stability that is equivalent to a secure press-fit component with no screws.Clinical trial registration: ClinicalTrials.gov (NCT03558217).
期刊介绍:
HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice.
The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit.
HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are:
• Biomaterials
• Biomechanics
• Conservative Hip Surgery
• Paediatrics
• Primary and Revision Hip Arthroplasty
• Traumatology