二极管激光940nm光活化漂白对不同复合树脂修复体颜色变化的影响。

IF 1.4 Q3 Pharmacology, Toxicology and Pharmaceutics
Amal Alaa Mawlood, Niaz H Hamasaeed
{"title":"二极管激光940nm光活化漂白对不同复合树脂修复体颜色变化的影响。","authors":"Amal Alaa Mawlood,&nbsp;Niaz H Hamasaeed","doi":"10.4103/japtr.japtr_45_23","DOIUrl":null,"url":null,"abstract":"<p><p>The study's main objective was to evaluate as well as compare the impact of diode laser 940 nm and conventional in-office bleaching technique on the color change of different composite resin restorations. A total of ninety composite resin discs (CRDs) were made from Filtek™ Bulk Fill, nanohybrid composite resin Filtek™ Z550 XT Universal Restorative, and flowable composite resin restoration Filtek™ Z350xt Flowable Composite. Group A: (30) CRD for Filtek™ Bulk Fill, group B: (30) CRD for Filtek™ Z550 XT Universal Restorative, and group C: (30) CRD for Filtek™ Z350xt Flowable Composite. A1, B1, and C1: (10 CRD in each group): Control group without bleaching. A2, B2, and C2: 10 CRD in each group bleached with Laser White20 without laser activation. A3, B3, and C3: 10 CRD in each group bleached with Laser White20 and activated by diode laser 940 nm. The color was evaluated using a dental spectrophotometer. One-way ANOVA was utilized for the comparison of the color stability of the CRD. <i>P</i> < 0.05 is regarded as statically significant. Both conventional and diode laser in-office vital tooth bleaching protocols affected the color stability of composite resin restorations. The result demonstrated that bleaching without laser activation produced color change (mean [8.30], standard deviation [SD] (1.95) <i>P</i> [< 0.001]), whereas the bleaching and activation by diode laser produced color change (mean [8.11], SD [1.99], <i>P</i> [< 0.001]). Both types of bleaching protocol affected composite resin restorations' color stability. In all tested materials, color changes after the bleaching protocol were clinically perceptible. The restorations following the bleaching procedure are required to be replaced by clinicians.</p>","PeriodicalId":14877,"journal":{"name":"Journal of Advanced Pharmaceutical Technology & Research","volume":"14 2","pages":"155-160"},"PeriodicalIF":1.4000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a4/11/JAPTR-14-155.PMC10226697.pdf","citationCount":"0","resultStr":"{\"title\":\"The impact of the diode laser 940 nm photoactivated bleaching on color change of different composite resin restorations.\",\"authors\":\"Amal Alaa Mawlood,&nbsp;Niaz H Hamasaeed\",\"doi\":\"10.4103/japtr.japtr_45_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The study's main objective was to evaluate as well as compare the impact of diode laser 940 nm and conventional in-office bleaching technique on the color change of different composite resin restorations. A total of ninety composite resin discs (CRDs) were made from Filtek™ Bulk Fill, nanohybrid composite resin Filtek™ Z550 XT Universal Restorative, and flowable composite resin restoration Filtek™ Z350xt Flowable Composite. Group A: (30) CRD for Filtek™ Bulk Fill, group B: (30) CRD for Filtek™ Z550 XT Universal Restorative, and group C: (30) CRD for Filtek™ Z350xt Flowable Composite. A1, B1, and C1: (10 CRD in each group): Control group without bleaching. A2, B2, and C2: 10 CRD in each group bleached with Laser White20 without laser activation. A3, B3, and C3: 10 CRD in each group bleached with Laser White20 and activated by diode laser 940 nm. The color was evaluated using a dental spectrophotometer. One-way ANOVA was utilized for the comparison of the color stability of the CRD. <i>P</i> < 0.05 is regarded as statically significant. Both conventional and diode laser in-office vital tooth bleaching protocols affected the color stability of composite resin restorations. The result demonstrated that bleaching without laser activation produced color change (mean [8.30], standard deviation [SD] (1.95) <i>P</i> [< 0.001]), whereas the bleaching and activation by diode laser produced color change (mean [8.11], SD [1.99], <i>P</i> [< 0.001]). Both types of bleaching protocol affected composite resin restorations' color stability. In all tested materials, color changes after the bleaching protocol were clinically perceptible. The restorations following the bleaching procedure are required to be replaced by clinicians.</p>\",\"PeriodicalId\":14877,\"journal\":{\"name\":\"Journal of Advanced Pharmaceutical Technology & Research\",\"volume\":\"14 2\",\"pages\":\"155-160\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a4/11/JAPTR-14-155.PMC10226697.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Pharmaceutical Technology & Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/japtr.japtr_45_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/4/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Pharmaceutical Technology & Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/japtr.japtr_45_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

摘要

本研究的主要目的是评估和比较940nm二极管激光和常规办公室漂白技术对不同复合树脂修复体颜色变化的影响。共有90个复合树脂圆盘(CRD)由Filtek制成™ Bulk Fill,纳米杂化复合树脂Filtek™ Z550XT通用修复性可流动复合树脂修复体Filtek™ Z350xt可流动复合材料。A组:(30)Filtek CRD™ 散装填充,B组:Filtek的(30)CRD™ Z550 XT通用修复剂和C组:Filtek的(30)CRD™ Z350xt可流动复合材料。A1、B1和C1:(每组10个CRD):对照组,无漂白。A2、B2和C2:10 CRD,每组用Laser White20漂白,没有激光活化。A3、B3和C3:每组10个CRD,用Laser White20漂白并用二极管激光器940nm激活。使用牙科分光光度计评估颜色。单向方差分析用于CRD颜色稳定性的比较。P<0.05为静态显著。传统和二极管激光办公室重要的牙齿漂白方案都会影响复合树脂修复体的颜色稳定性。结果表明,未经激光活化的漂白会产生颜色变化(平均值[8.30],标准偏差[SD](1.95)P[<0.001]),而经二极管激光活化的脱色会产生颜色改变(平均值-8.11],标准差[1.99],P[<0.0001])。这两种漂白方案都会影响复合树脂修复体的颜色稳定性。在所有测试材料中,漂白方案后的颜色变化在临床上是可察觉的。漂白程序后的修复体需要由临床医生更换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The impact of the diode laser 940 nm photoactivated bleaching on color change of different composite resin restorations.

The impact of the diode laser 940 nm photoactivated bleaching on color change of different composite resin restorations.

The study's main objective was to evaluate as well as compare the impact of diode laser 940 nm and conventional in-office bleaching technique on the color change of different composite resin restorations. A total of ninety composite resin discs (CRDs) were made from Filtek™ Bulk Fill, nanohybrid composite resin Filtek™ Z550 XT Universal Restorative, and flowable composite resin restoration Filtek™ Z350xt Flowable Composite. Group A: (30) CRD for Filtek™ Bulk Fill, group B: (30) CRD for Filtek™ Z550 XT Universal Restorative, and group C: (30) CRD for Filtek™ Z350xt Flowable Composite. A1, B1, and C1: (10 CRD in each group): Control group without bleaching. A2, B2, and C2: 10 CRD in each group bleached with Laser White20 without laser activation. A3, B3, and C3: 10 CRD in each group bleached with Laser White20 and activated by diode laser 940 nm. The color was evaluated using a dental spectrophotometer. One-way ANOVA was utilized for the comparison of the color stability of the CRD. P < 0.05 is regarded as statically significant. Both conventional and diode laser in-office vital tooth bleaching protocols affected the color stability of composite resin restorations. The result demonstrated that bleaching without laser activation produced color change (mean [8.30], standard deviation [SD] (1.95) P [< 0.001]), whereas the bleaching and activation by diode laser produced color change (mean [8.11], SD [1.99], P [< 0.001]). Both types of bleaching protocol affected composite resin restorations' color stability. In all tested materials, color changes after the bleaching protocol were clinically perceptible. The restorations following the bleaching procedure are required to be replaced by clinicians.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
7.10%
发文量
44
审稿时长
20 weeks
期刊介绍: Journal of Advanced Pharmaceutical Technology & Research (JAPTR) is an Official Publication of Society of Pharmaceutical Education & Research™. It is an international journal published Quarterly. Journal of Advanced Pharmaceutical Technology & Research (JAPTR) is available in online and print version. It is a peer reviewed journal aiming to communicate high quality original research work, reviews, short communications, case report, Ethics Forum, Education Forum and Letter to editor that contribute significantly to further the scientific knowledge related to the field of Pharmacy i.e. Pharmaceutics, Pharmacology, Pharmacognosy, Pharmaceutical Chemistry. Articles with timely interest and newer research concepts will be given more preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信