利用基于光电离检测器(PID)的方法估计液相和气相气味剂浓度之间的关系。

IF 2.8 4区 心理学 Q1 BEHAVIORAL SCIENCES
Liam Jennings, Ellie Williams, Samuel Caton, Marta Avlas, Adam Dewan
{"title":"利用基于光电离检测器(PID)的方法估计液相和气相气味剂浓度之间的关系。","authors":"Liam Jennings,&nbsp;Ellie Williams,&nbsp;Samuel Caton,&nbsp;Marta Avlas,&nbsp;Adam Dewan","doi":"10.1093/chemse/bjac038","DOIUrl":null,"url":null,"abstract":"<p><p>Olfactory studies frequently utilize odor stimuli consisting of volatiles created from liquid dilutions of various chemicals. A problem arises if the researcher relies on these liquid dilutions to extrapolate vapor concentrations based on ideal gas behavior. For most chemicals, the relationship between liquid and vapor concentration deviates from these laws of proportionality due to interactions between the chemical and the solvent. Here, we describe a method to estimate vapor-phase concentrations of diluted odorants using a photoionization detector. To demonstrate the utility of this method, we assessed the relationship between liquid-/vapor-phase concentrations for 14 odorants (7 alcohols, 1 ester, and 6 aldehydes) in 5 different solvents (water, mineral oil, diethyl phthalate, dipropylene glycol, and propylene glycol). An analysis of 7 additional esters is also included to assess how carbon chain length and functional group, interacts with these solvents (for a total of 105 odorant/solvent pairs). Our resulting equilibrium equations successfully corrected for behavioral sensitivity differences observed in mice tested with the same odorant in different solvents and were overall similar to published measurements using a gas chromatography-based approach. In summary, this method should allow researchers to determine the vapor-phase concentration of diluted odorants and will hopefully assist in more accurate comparisons of odorant concentrations across olfactory studies.</p>","PeriodicalId":9771,"journal":{"name":"Chemical Senses","volume":"48 ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208748/pdf/bjac038.pdf","citationCount":"3","resultStr":"{\"title\":\"Estimating the relationship between liquid- and vapor-phase odorant concentrations using a photoionization detector (PID)-based approach.\",\"authors\":\"Liam Jennings,&nbsp;Ellie Williams,&nbsp;Samuel Caton,&nbsp;Marta Avlas,&nbsp;Adam Dewan\",\"doi\":\"10.1093/chemse/bjac038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Olfactory studies frequently utilize odor stimuli consisting of volatiles created from liquid dilutions of various chemicals. A problem arises if the researcher relies on these liquid dilutions to extrapolate vapor concentrations based on ideal gas behavior. For most chemicals, the relationship between liquid and vapor concentration deviates from these laws of proportionality due to interactions between the chemical and the solvent. Here, we describe a method to estimate vapor-phase concentrations of diluted odorants using a photoionization detector. To demonstrate the utility of this method, we assessed the relationship between liquid-/vapor-phase concentrations for 14 odorants (7 alcohols, 1 ester, and 6 aldehydes) in 5 different solvents (water, mineral oil, diethyl phthalate, dipropylene glycol, and propylene glycol). An analysis of 7 additional esters is also included to assess how carbon chain length and functional group, interacts with these solvents (for a total of 105 odorant/solvent pairs). Our resulting equilibrium equations successfully corrected for behavioral sensitivity differences observed in mice tested with the same odorant in different solvents and were overall similar to published measurements using a gas chromatography-based approach. In summary, this method should allow researchers to determine the vapor-phase concentration of diluted odorants and will hopefully assist in more accurate comparisons of odorant concentrations across olfactory studies.</p>\",\"PeriodicalId\":9771,\"journal\":{\"name\":\"Chemical Senses\",\"volume\":\"48 \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208748/pdf/bjac038.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemical Senses\",\"FirstCategoryId\":\"102\",\"ListUrlMain\":\"https://doi.org/10.1093/chemse/bjac038\",\"RegionNum\":4,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BEHAVIORAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Senses","FirstCategoryId":"102","ListUrlMain":"https://doi.org/10.1093/chemse/bjac038","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BEHAVIORAL SCIENCES","Score":null,"Total":0}
引用次数: 3

摘要

嗅觉研究经常利用由各种化学物质的液体稀释产生的挥发物组成的气味刺激。如果研究人员依靠这些液体稀释来推断基于理想气体行为的蒸汽浓度,问题就出现了。对于大多数化学品,由于化学品和溶剂之间的相互作用,液体和蒸汽浓度之间的关系偏离了这些比例定律。在这里,我们描述了一种方法来估计气相浓度稀释的气味剂使用光电离检测器。为了证明该方法的实用性,我们评估了14种气味剂(7种醇类、1种酯类和6种醛类)在5种不同溶剂(水、矿物油、邻苯二甲酸二乙酯、二丙二醇和丙二醇)中的液/气相浓度之间的关系。另外还分析了7种酯,以评估碳链长度和官能团如何与这些溶剂相互作用(总共105对气味剂/溶剂)。我们得到的平衡方程成功地纠正了在不同溶剂中使用相同气味的小鼠观察到的行为敏感性差异,并且总体上与使用基于气相色谱的方法发表的测量结果相似。总之,这种方法应该允许研究人员确定稀释气味剂的气相浓度,并有望帮助更准确地比较嗅觉研究中的气味浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimating the relationship between liquid- and vapor-phase odorant concentrations using a photoionization detector (PID)-based approach.

Olfactory studies frequently utilize odor stimuli consisting of volatiles created from liquid dilutions of various chemicals. A problem arises if the researcher relies on these liquid dilutions to extrapolate vapor concentrations based on ideal gas behavior. For most chemicals, the relationship between liquid and vapor concentration deviates from these laws of proportionality due to interactions between the chemical and the solvent. Here, we describe a method to estimate vapor-phase concentrations of diluted odorants using a photoionization detector. To demonstrate the utility of this method, we assessed the relationship between liquid-/vapor-phase concentrations for 14 odorants (7 alcohols, 1 ester, and 6 aldehydes) in 5 different solvents (water, mineral oil, diethyl phthalate, dipropylene glycol, and propylene glycol). An analysis of 7 additional esters is also included to assess how carbon chain length and functional group, interacts with these solvents (for a total of 105 odorant/solvent pairs). Our resulting equilibrium equations successfully corrected for behavioral sensitivity differences observed in mice tested with the same odorant in different solvents and were overall similar to published measurements using a gas chromatography-based approach. In summary, this method should allow researchers to determine the vapor-phase concentration of diluted odorants and will hopefully assist in more accurate comparisons of odorant concentrations across olfactory studies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Chemical Senses
Chemical Senses 医学-行为科学
CiteScore
8.60
自引率
2.90%
发文量
25
审稿时长
1 months
期刊介绍: Chemical Senses publishes original research and review papers on all aspects of chemoreception in both humans and animals. An important part of the journal''s coverage is devoted to techniques and the development and application of new methods for investigating chemoreception and chemosensory structures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信