Mehmet Zülküf Karahan, Adem Aktan, Tuncay Güzel, Raif Kılıç, Serhat Günlü, Muhammed Demir, Faruk Ertaş
{"title":"经导管主动脉瓣置换术后的血液参数评估","authors":"Mehmet Zülküf Karahan, Adem Aktan, Tuncay Güzel, Raif Kılıç, Serhat Günlü, Muhammed Demir, Faruk Ertaş","doi":"10.1177/00033197231177397","DOIUrl":null,"url":null,"abstract":"<p><p>Although transcatheter aortic valve replacement (TAVR) is safe and effective, mortality and bleeding events post procedure are important. The present study investigated the changes in hematologic parameters to evaluate whether they predict mortality or major bleeding. We enrolled 248 consecutive patients (44.8% male; mean age 79.0 ± 6.4 years) undergoing TAVR. In addition to demographic and clinical examination, blood parameters were recorded before TAVR, at discharge, 1 month and 1 year. Hemoglobin levels before TAVR 12.1 ± 1.8 g/dL, 10.8 ± 1.7 g/dL at discharge, 11.7 ± 1.7 g/dL at first month, 11.8 ± 1.4 g/dL at first year (Hemoglobin values compared with pre-TAVR, <i>P</i> < .001, <i>P</i> = .019, <i>P</i> = .047, respectively). Mean platelet volume (MPV) before TAVR 8.72 ± 1.71 fL, 8.16 ± 1.46 fL at discharge, 8.09 ± 1.44 fL at first month, 7.94 ± 1.18 fL at first year (MPV values compared with pre-TAVR, <i>P</i> < .001, <i>P</i> < .001, <i>P</i> < .001, respectively). Other hematologic parameters were also evaluated. Hemoglobin, platelet count, MPV, and red cell distribution width before the procedure, at discharge, and at the first year did not predict mortality and major bleeding in receiver operating characteristic analysis. After multivariate Cox regression analysis, hematologic parameters were not independent predictors of in-hospital mortality, major bleeding, and death at 1 year after TAVR.</p>","PeriodicalId":8264,"journal":{"name":"Angiology","volume":" ","pages":"764-771"},"PeriodicalIF":2.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Hematological Parameters After Transcatheter Aortic Valve Replacement.\",\"authors\":\"Mehmet Zülküf Karahan, Adem Aktan, Tuncay Güzel, Raif Kılıç, Serhat Günlü, Muhammed Demir, Faruk Ertaş\",\"doi\":\"10.1177/00033197231177397\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Although transcatheter aortic valve replacement (TAVR) is safe and effective, mortality and bleeding events post procedure are important. The present study investigated the changes in hematologic parameters to evaluate whether they predict mortality or major bleeding. We enrolled 248 consecutive patients (44.8% male; mean age 79.0 ± 6.4 years) undergoing TAVR. In addition to demographic and clinical examination, blood parameters were recorded before TAVR, at discharge, 1 month and 1 year. Hemoglobin levels before TAVR 12.1 ± 1.8 g/dL, 10.8 ± 1.7 g/dL at discharge, 11.7 ± 1.7 g/dL at first month, 11.8 ± 1.4 g/dL at first year (Hemoglobin values compared with pre-TAVR, <i>P</i> < .001, <i>P</i> = .019, <i>P</i> = .047, respectively). Mean platelet volume (MPV) before TAVR 8.72 ± 1.71 fL, 8.16 ± 1.46 fL at discharge, 8.09 ± 1.44 fL at first month, 7.94 ± 1.18 fL at first year (MPV values compared with pre-TAVR, <i>P</i> < .001, <i>P</i> < .001, <i>P</i> < .001, respectively). Other hematologic parameters were also evaluated. Hemoglobin, platelet count, MPV, and red cell distribution width before the procedure, at discharge, and at the first year did not predict mortality and major bleeding in receiver operating characteristic analysis. After multivariate Cox regression analysis, hematologic parameters were not independent predictors of in-hospital mortality, major bleeding, and death at 1 year after TAVR.</p>\",\"PeriodicalId\":8264,\"journal\":{\"name\":\"Angiology\",\"volume\":\" \",\"pages\":\"764-771\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Angiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00033197231177397\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00033197231177397","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
Evaluation of Hematological Parameters After Transcatheter Aortic Valve Replacement.
Although transcatheter aortic valve replacement (TAVR) is safe and effective, mortality and bleeding events post procedure are important. The present study investigated the changes in hematologic parameters to evaluate whether they predict mortality or major bleeding. We enrolled 248 consecutive patients (44.8% male; mean age 79.0 ± 6.4 years) undergoing TAVR. In addition to demographic and clinical examination, blood parameters were recorded before TAVR, at discharge, 1 month and 1 year. Hemoglobin levels before TAVR 12.1 ± 1.8 g/dL, 10.8 ± 1.7 g/dL at discharge, 11.7 ± 1.7 g/dL at first month, 11.8 ± 1.4 g/dL at first year (Hemoglobin values compared with pre-TAVR, P < .001, P = .019, P = .047, respectively). Mean platelet volume (MPV) before TAVR 8.72 ± 1.71 fL, 8.16 ± 1.46 fL at discharge, 8.09 ± 1.44 fL at first month, 7.94 ± 1.18 fL at first year (MPV values compared with pre-TAVR, P < .001, P < .001, P < .001, respectively). Other hematologic parameters were also evaluated. Hemoglobin, platelet count, MPV, and red cell distribution width before the procedure, at discharge, and at the first year did not predict mortality and major bleeding in receiver operating characteristic analysis. After multivariate Cox regression analysis, hematologic parameters were not independent predictors of in-hospital mortality, major bleeding, and death at 1 year after TAVR.
期刊介绍:
A presentation of original, peer-reviewed original articles, review and case reports relative to all phases of all vascular diseases, Angiology (ANG) offers more than a typical cardiology journal. With approximately 1000 pages per year covering diagnostic methods, therapeutic approaches, and clinical and laboratory research, ANG is among the most informative publications in the field of peripheral vascular and cardiovascular diseases. This journal is a member of the Committee on Publication Ethics (COPE). Average time from submission to first decision: 13 days