类似的口内判断基台预备角度几乎是不可能的!至少要避免切口不足。

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Felix H Blankenstein, Jelka Plake
{"title":"类似的口内判断基台预备角度几乎是不可能的!至少要避免切口不足。","authors":"Felix H Blankenstein, Jelka Plake","doi":"10.3290/j.ijcd.b4110975","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>A total occlusal convergence (TOC) angle (ϕ) of 6 degrees is a typical crown preparation requirement. It has been shown that this is difficult to achieve clinically. The present study therefore aims to compare the ability of students to judge different steepnesses, including a -1-degree undercut of prepared canines and molars, under clinical conditions with different analog tools.</p><p><strong>Materials and methods: </strong>The complete dentures of a patient were duplicated without denture teeth 16, 23, 33, and 46. For each of these gaps, six crown stumps were milled with ϕ/2 = -1, 3, 6, 9, 12, and 15 degrees, each of which was insertable using mini-magnets. A total of 144 dental students, 48 students each from the 1st, 6th, or 9th semester, estimated these angles intraorally with various aiding tools: In addition to basic dental instruments, they used a parallelometer mirror, an analog clock dial with a 6-degree visualization, and a scale of tooth stumps with ϕ/2 between -1 and 15 degrees.</p><p><strong>Results: </strong>The widely demanded 3 degrees were hardly recognized, but assumed to be steeper or even undercut. In contrast, the -1-degree divergent stump walls were predominantly estimated as parallel-walled or slightly conical. With increasing taper, the stumps tended to be classified as steeper, ie, \"better.\" The additional tools did not result in a general improvement of the estimation performance. Students from higher semesters did not achieve better results.</p><p><strong>Conclusion: </strong>The present authors question the objectivity of an exclusively visual assessment of crown stump taper. It appears that dental training should at least focus on avoiding undercuts as the minimal prerequisite for an accurate intraoral scanning procedure. Digital control of the preparation angle by an intraoral scan and immediate clinical implementation of these results could help to produce appropriate preparations.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"169-177"},"PeriodicalIF":1.8000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The analogous intraoral judgement of the abutment preparation angle is almost impossible! At least avoid undercuts.\",\"authors\":\"Felix H Blankenstein, Jelka Plake\",\"doi\":\"10.3290/j.ijcd.b4110975\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>A total occlusal convergence (TOC) angle (ϕ) of 6 degrees is a typical crown preparation requirement. It has been shown that this is difficult to achieve clinically. The present study therefore aims to compare the ability of students to judge different steepnesses, including a -1-degree undercut of prepared canines and molars, under clinical conditions with different analog tools.</p><p><strong>Materials and methods: </strong>The complete dentures of a patient were duplicated without denture teeth 16, 23, 33, and 46. For each of these gaps, six crown stumps were milled with ϕ/2 = -1, 3, 6, 9, 12, and 15 degrees, each of which was insertable using mini-magnets. A total of 144 dental students, 48 students each from the 1st, 6th, or 9th semester, estimated these angles intraorally with various aiding tools: In addition to basic dental instruments, they used a parallelometer mirror, an analog clock dial with a 6-degree visualization, and a scale of tooth stumps with ϕ/2 between -1 and 15 degrees.</p><p><strong>Results: </strong>The widely demanded 3 degrees were hardly recognized, but assumed to be steeper or even undercut. In contrast, the -1-degree divergent stump walls were predominantly estimated as parallel-walled or slightly conical. With increasing taper, the stumps tended to be classified as steeper, ie, \\\"better.\\\" The additional tools did not result in a general improvement of the estimation performance. Students from higher semesters did not achieve better results.</p><p><strong>Conclusion: </strong>The present authors question the objectivity of an exclusively visual assessment of crown stump taper. It appears that dental training should at least focus on avoiding undercuts as the minimal prerequisite for an accurate intraoral scanning procedure. Digital control of the preparation angle by an intraoral scan and immediate clinical implementation of these results could help to produce appropriate preparations.</p>\",\"PeriodicalId\":48666,\"journal\":{\"name\":\"International Journal of Computerized Dentistry\",\"volume\":\"0 0\",\"pages\":\"169-177\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computerized Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ijcd.b4110975\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b4110975","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:典型的牙冠预备要求是总咬合会聚角(TOC)(j) 为 6 度。但临床上很难达到这一要求。因此,本研究旨在比较学生在临床条件下使用不同模拟工具判断不同陡度的能力,包括对准备好的犬齿和臼齿进行-1度的下切:对一名患者的全口义齿进行复制,不包括义齿16、23、33和46。在每个间隙中,都铣制了 6 个牙冠桩,j/2 =-1、3、6、9、12 和 15 度,每个桩都可以使用微型磁铁插入。共有 144 名牙科学生(第一、第六或第九学期各 48 名学生)使用各种辅助工具在口腔内估算这些角度:除了基本的牙科器械外,他们还使用了平行计镜、6 度可视化模拟时钟表盘和牙桩刻度尺(ϕ/2 介于 -1 和 15 度之间):结果:人们普遍认为 3 度的坡度较陡,甚至认为是下切。与此相反,偏离 1 度的齿残壁主要被认为是平行壁或略呈锥形。随着锥度的增加,树桩往往被归类为更陡峭,即 "更好"。额外的工具并没有普遍提高估算成绩。结论:本文作者对牙冠残端锥度的纯视觉评估的客观性提出了质疑。由此看来,牙科培训至少应将避免欠切作为准确口内扫描程序的最基本前提。通过口内扫描对预备角度进行数字化控制,并将结果立即应用于临床,这将有助于制作出合适的预备体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The analogous intraoral judgement of the abutment preparation angle is almost impossible! At least avoid undercuts.

Aim: A total occlusal convergence (TOC) angle (ϕ) of 6 degrees is a typical crown preparation requirement. It has been shown that this is difficult to achieve clinically. The present study therefore aims to compare the ability of students to judge different steepnesses, including a -1-degree undercut of prepared canines and molars, under clinical conditions with different analog tools.

Materials and methods: The complete dentures of a patient were duplicated without denture teeth 16, 23, 33, and 46. For each of these gaps, six crown stumps were milled with ϕ/2 = -1, 3, 6, 9, 12, and 15 degrees, each of which was insertable using mini-magnets. A total of 144 dental students, 48 students each from the 1st, 6th, or 9th semester, estimated these angles intraorally with various aiding tools: In addition to basic dental instruments, they used a parallelometer mirror, an analog clock dial with a 6-degree visualization, and a scale of tooth stumps with ϕ/2 between -1 and 15 degrees.

Results: The widely demanded 3 degrees were hardly recognized, but assumed to be steeper or even undercut. In contrast, the -1-degree divergent stump walls were predominantly estimated as parallel-walled or slightly conical. With increasing taper, the stumps tended to be classified as steeper, ie, "better." The additional tools did not result in a general improvement of the estimation performance. Students from higher semesters did not achieve better results.

Conclusion: The present authors question the objectivity of an exclusively visual assessment of crown stump taper. It appears that dental training should at least focus on avoiding undercuts as the minimal prerequisite for an accurate intraoral scanning procedure. Digital control of the preparation angle by an intraoral scan and immediate clinical implementation of these results could help to produce appropriate preparations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信