示波式血压监测仪对房颤筛查的诊断准确性。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Linyi Li, Sen Bing, Kui Liu, Jun Jiang, Jieqiong Zhang, Changsheng Chen, Yi Wan
{"title":"示波式血压监测仪对房颤筛查的诊断准确性。","authors":"Linyi Li,&nbsp;Sen Bing,&nbsp;Kui Liu,&nbsp;Jun Jiang,&nbsp;Jieqiong Zhang,&nbsp;Changsheng Chen,&nbsp;Yi Wan","doi":"10.1097/MBP.0000000000000645","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Atrial fibrillation is the most common arrhythmia of clinical significance and hypertension is one of its major risk factors. This study aimed to evaluate the diagnostic accuracy of an automated oscillometric blood pressure (BP) monitor with the function of atrial fibrillation detection for atrial fibrillation screening.</p><p><strong>Materials and methods: </strong>Patients attending outpatient cardiology clinics were recruited for atrial fibrillation screening by the BP monitor with triplicate BP measurements for atrial fibrillation detection. Furthermore, a single-lead ECG was recorded simultaneously for comparison as the reference standard. The diagnostic test's evaluation index were analyzed, including sensitivity, specificity, and receiver operator characteristic (ROC) analysis.</p><p><strong>Results: </strong>A total of 295 participants were analyzed including 166 males and 129 females, with an average age of 72.5 ± 5.9 years. The sensitivity and specificity for atrial fibrillation detection by the device were 1.000 and 0.904, respectively, with the area under the ROC curve of 0.952 (95% confidence interval: 0.929-0.975, P  < 0.001). Furthermore, the device had a Kappa-value of 0.781 ( P  < 0.001) with the single-lead ECG in detecting atrial fibrillation.</p><p><strong>Conclusion: </strong>The automated oscillometric BP monitor (G.LAB MD41A0) with atrial fibrillation detection function has high sensitivity and specificity with good accuracy for atrial fibrillation screening, which could be used as a reliable screening tool for the early detection of atrial fibrillation with potential benefits.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening.\",\"authors\":\"Linyi Li,&nbsp;Sen Bing,&nbsp;Kui Liu,&nbsp;Jun Jiang,&nbsp;Jieqiong Zhang,&nbsp;Changsheng Chen,&nbsp;Yi Wan\",\"doi\":\"10.1097/MBP.0000000000000645\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Atrial fibrillation is the most common arrhythmia of clinical significance and hypertension is one of its major risk factors. This study aimed to evaluate the diagnostic accuracy of an automated oscillometric blood pressure (BP) monitor with the function of atrial fibrillation detection for atrial fibrillation screening.</p><p><strong>Materials and methods: </strong>Patients attending outpatient cardiology clinics were recruited for atrial fibrillation screening by the BP monitor with triplicate BP measurements for atrial fibrillation detection. Furthermore, a single-lead ECG was recorded simultaneously for comparison as the reference standard. The diagnostic test's evaluation index were analyzed, including sensitivity, specificity, and receiver operator characteristic (ROC) analysis.</p><p><strong>Results: </strong>A total of 295 participants were analyzed including 166 males and 129 females, with an average age of 72.5 ± 5.9 years. The sensitivity and specificity for atrial fibrillation detection by the device were 1.000 and 0.904, respectively, with the area under the ROC curve of 0.952 (95% confidence interval: 0.929-0.975, P  < 0.001). Furthermore, the device had a Kappa-value of 0.781 ( P  < 0.001) with the single-lead ECG in detecting atrial fibrillation.</p><p><strong>Conclusion: </strong>The automated oscillometric BP monitor (G.LAB MD41A0) with atrial fibrillation detection function has high sensitivity and specificity with good accuracy for atrial fibrillation screening, which could be used as a reliable screening tool for the early detection of atrial fibrillation with potential benefits.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBP.0000000000000645\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000645","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

目的:房颤是临床上最常见的心律失常,高血压是其主要危险因素之一。本研究旨在评估具有房颤检测功能的自动示波血压(BP)监测仪在房颤筛查中的诊断准确性。材料和方法:招募在心脏病门诊就诊的患者,通过血压监测仪进行房颤筛查,并进行三次血压检测。同时记录单导联心电图作为对照标准。分析诊断试验的评价指标,包括敏感性、特异性和受试者操作特征(receiver operator characteristic, ROC)分析。结果:共纳入295人,其中男性166人,女性129人,平均年龄72.5±5.9岁。该装置检测心房颤动的灵敏度为1.000,特异度为0.904,ROC曲线下面积为0.952(95%可信区间:0.929-0.975,P)。具有房颤检测功能的自动示波式血压监测仪(G.LAB MD41A0)对房颤筛查具有高灵敏度、特异性和良好的准确性,可作为早期发现房颤的可靠筛查工具,具有潜在的益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening.

Objective: Atrial fibrillation is the most common arrhythmia of clinical significance and hypertension is one of its major risk factors. This study aimed to evaluate the diagnostic accuracy of an automated oscillometric blood pressure (BP) monitor with the function of atrial fibrillation detection for atrial fibrillation screening.

Materials and methods: Patients attending outpatient cardiology clinics were recruited for atrial fibrillation screening by the BP monitor with triplicate BP measurements for atrial fibrillation detection. Furthermore, a single-lead ECG was recorded simultaneously for comparison as the reference standard. The diagnostic test's evaluation index were analyzed, including sensitivity, specificity, and receiver operator characteristic (ROC) analysis.

Results: A total of 295 participants were analyzed including 166 males and 129 females, with an average age of 72.5 ± 5.9 years. The sensitivity and specificity for atrial fibrillation detection by the device were 1.000 and 0.904, respectively, with the area under the ROC curve of 0.952 (95% confidence interval: 0.929-0.975, P  < 0.001). Furthermore, the device had a Kappa-value of 0.781 ( P  < 0.001) with the single-lead ECG in detecting atrial fibrillation.

Conclusion: The automated oscillometric BP monitor (G.LAB MD41A0) with atrial fibrillation detection function has high sensitivity and specificity with good accuracy for atrial fibrillation screening, which could be used as a reliable screening tool for the early detection of atrial fibrillation with potential benefits.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信