George Brown, Andrea Ong, Patrick Juliebø-Jones, Niall F Davis, Andreas Skolarikos, Bhaskar Somani
{"title":"一次性输尿管镜检查与环境足迹:当前证据综述。","authors":"George Brown, Andrea Ong, Patrick Juliebø-Jones, Niall F Davis, Andreas Skolarikos, Bhaskar Somani","doi":"10.1007/s11934-023-01154-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>Ureteroscopy is a well-established treatment modality for kidney and ureteric calculi in addition to playing a key role in upper tract cancer diagnostics. Traditional reusable flexible ureteroscopes are technologically advanced and expensive pieces of equipment that require repeat sterilisation and periodical repair. These issues have led to the development of single-use flexible ureteroscopes that are disposed of after each case. Whilst this may be advantageous in many respects, the environmental impact of such technology is yet to be fully determined. The aim of this review is to therefore identify and summarise the available literature concerning the environmental footprint of single-use ureteroscopy.</p><p><strong>Recent findings: </strong>To identify the latest research on this topic, a systematic search of world literature was conducted using the Medline, Embase, and PsycINFO databases. PRISMA guidelines were followed and articles were assessed by all authors and relevant study results were included in a narrative format. Only one relevant article was identified and included. This study found that a single-use flexible ureteroscope (LithoVue<sup>TM</sup> by Boston Scientific) generated an equivalent amount of carbon dioxide per case to a contemporary reusable flexible ureteroscope. Literature concerning the environmental footprint of single-use ureteroscopy is worryingly lacking. No conclusions can be definitively drawn from a single study and further research is imperative given the global climate crisis and the significant contribution that healthcare services have to the environmental problem.</p>","PeriodicalId":11112,"journal":{"name":"Current Urology Reports","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Single-Use Ureteroscopy and Environmental Footprint: Review of Current Evidence.\",\"authors\":\"George Brown, Andrea Ong, Patrick Juliebø-Jones, Niall F Davis, Andreas Skolarikos, Bhaskar Somani\",\"doi\":\"10.1007/s11934-023-01154-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose of review: </strong>Ureteroscopy is a well-established treatment modality for kidney and ureteric calculi in addition to playing a key role in upper tract cancer diagnostics. Traditional reusable flexible ureteroscopes are technologically advanced and expensive pieces of equipment that require repeat sterilisation and periodical repair. These issues have led to the development of single-use flexible ureteroscopes that are disposed of after each case. Whilst this may be advantageous in many respects, the environmental impact of such technology is yet to be fully determined. The aim of this review is to therefore identify and summarise the available literature concerning the environmental footprint of single-use ureteroscopy.</p><p><strong>Recent findings: </strong>To identify the latest research on this topic, a systematic search of world literature was conducted using the Medline, Embase, and PsycINFO databases. PRISMA guidelines were followed and articles were assessed by all authors and relevant study results were included in a narrative format. Only one relevant article was identified and included. This study found that a single-use flexible ureteroscope (LithoVue<sup>TM</sup> by Boston Scientific) generated an equivalent amount of carbon dioxide per case to a contemporary reusable flexible ureteroscope. Literature concerning the environmental footprint of single-use ureteroscopy is worryingly lacking. No conclusions can be definitively drawn from a single study and further research is imperative given the global climate crisis and the significant contribution that healthcare services have to the environmental problem.</p>\",\"PeriodicalId\":11112,\"journal\":{\"name\":\"Current Urology Reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Urology Reports\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11934-023-01154-9\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Urology Reports","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11934-023-01154-9","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
Single-Use Ureteroscopy and Environmental Footprint: Review of Current Evidence.
Purpose of review: Ureteroscopy is a well-established treatment modality for kidney and ureteric calculi in addition to playing a key role in upper tract cancer diagnostics. Traditional reusable flexible ureteroscopes are technologically advanced and expensive pieces of equipment that require repeat sterilisation and periodical repair. These issues have led to the development of single-use flexible ureteroscopes that are disposed of after each case. Whilst this may be advantageous in many respects, the environmental impact of such technology is yet to be fully determined. The aim of this review is to therefore identify and summarise the available literature concerning the environmental footprint of single-use ureteroscopy.
Recent findings: To identify the latest research on this topic, a systematic search of world literature was conducted using the Medline, Embase, and PsycINFO databases. PRISMA guidelines were followed and articles were assessed by all authors and relevant study results were included in a narrative format. Only one relevant article was identified and included. This study found that a single-use flexible ureteroscope (LithoVueTM by Boston Scientific) generated an equivalent amount of carbon dioxide per case to a contemporary reusable flexible ureteroscope. Literature concerning the environmental footprint of single-use ureteroscopy is worryingly lacking. No conclusions can be definitively drawn from a single study and further research is imperative given the global climate crisis and the significant contribution that healthcare services have to the environmental problem.
期刊介绍:
This journal intends to review the most important, recently published findings in the field of urology. By providing clear, insightful, balanced contributions by international experts, the journal elucidates current and emerging approaches to the care and prevention of urologic diseases and conditions.
We accomplish this aim by appointing international authorities to serve as Section Editors in key subject areas, such as benign prostatic hyperplasia, erectile dysfunction, female urology, and kidney disease. Section Editors, in turn, select topics for which leading experts contribute comprehensive review articles that emphasize new developments and recently published papers of major importance, highlighted by annotated reference lists. An international Editorial Board reviews the annual table of contents, suggests articles of special interest to their country/region, and ensures that topics are current and include emerging research. Commentaries from well-known figures in the field are also provided.