用于生物医学成像应用的CMOS时间数字转换器

IF 17.2 1区 工程技术 Q1 ENGINEERING, BIOMEDICAL
Ryan Scott;Wei Jiang;M. Jamal Deen
{"title":"用于生物医学成像应用的CMOS时间数字转换器","authors":"Ryan Scott;Wei Jiang;M. Jamal Deen","doi":"10.1109/RBME.2021.3092197","DOIUrl":null,"url":null,"abstract":"Time-to-digital converters (TDCs) are high-performance mixed-signal circuits capable of timestamping events with sub-gate delay resolution. As a result of their high-performance, in recent years TDCs were integrated in complementary metal-oxide-semiconductor (CMOS) technology with highly sensitive photodetectors known as single-photon avalanche diodes (SPADs), to form digital silicon photomultipliers (dSiPMs) and SPAD imagers. Time-resolved SPAD-based sensors are capable of detecting the absorption of a single photon and timestamping it with picosecond resolution. As such, SPAD-based sensors are very useful in the field of biomedical imaging, using time-of-flight (ToF) information to produce data that can be used to reconstruct high-quality biological images. Additionally, the capability of integration in standard CMOS technologies, allows SPAD-based sensors to provide high-performance, while maintaining low cost. In this paper, we present an overview of fundamental TDC principles, and an analysis of state-of-the-art TDCs. Furthermore, the integration of TDCs into dSiPMs and SPAD imagers will be discussed, with an analysis of the current results of TDCs in different biomedical imaging applications. Finally, several important research challenges for TDCs in biomedical imaging applications are presented.","PeriodicalId":39235,"journal":{"name":"IEEE Reviews in Biomedical Engineering","volume":"16 ","pages":"627-652"},"PeriodicalIF":17.2000,"publicationDate":"2021-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"CMOS Time-to-Digital Converters for Biomedical Imaging Applications\",\"authors\":\"Ryan Scott;Wei Jiang;M. Jamal Deen\",\"doi\":\"10.1109/RBME.2021.3092197\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Time-to-digital converters (TDCs) are high-performance mixed-signal circuits capable of timestamping events with sub-gate delay resolution. As a result of their high-performance, in recent years TDCs were integrated in complementary metal-oxide-semiconductor (CMOS) technology with highly sensitive photodetectors known as single-photon avalanche diodes (SPADs), to form digital silicon photomultipliers (dSiPMs) and SPAD imagers. Time-resolved SPAD-based sensors are capable of detecting the absorption of a single photon and timestamping it with picosecond resolution. As such, SPAD-based sensors are very useful in the field of biomedical imaging, using time-of-flight (ToF) information to produce data that can be used to reconstruct high-quality biological images. Additionally, the capability of integration in standard CMOS technologies, allows SPAD-based sensors to provide high-performance, while maintaining low cost. In this paper, we present an overview of fundamental TDC principles, and an analysis of state-of-the-art TDCs. Furthermore, the integration of TDCs into dSiPMs and SPAD imagers will be discussed, with an analysis of the current results of TDCs in different biomedical imaging applications. Finally, several important research challenges for TDCs in biomedical imaging applications are presented.\",\"PeriodicalId\":39235,\"journal\":{\"name\":\"IEEE Reviews in Biomedical Engineering\",\"volume\":\"16 \",\"pages\":\"627-652\"},\"PeriodicalIF\":17.2000,\"publicationDate\":\"2021-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Reviews in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9464686/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Reviews in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/9464686/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 5

摘要

时间-数字转换器(TDCs)是一种高性能的混合信号电路,能够以子门延迟分辨率对事件进行时间戳。由于其高性能,近年来,TDCs被集成在互补金属氧化物半导体(CMOS)技术中,与被称为单光子雪崩二极管(SPAD)的高灵敏度光电探测器集成,以形成数字硅光电倍增器(dSiPM)和SPAD成像器。基于时间分辨SPAD的传感器能够检测单个光子的吸收,并以皮秒分辨率对其进行时间戳。因此,基于SPAD的传感器在生物医学成像领域非常有用,它使用飞行时间(ToF)信息来产生可用于重建高质量生物图像的数据。此外,标准CMOS技术的集成能力使基于SPAD的传感器能够提供高性能,同时保持低成本。在本文中,我们概述了TDC的基本原理,并分析了最先进的TDC。此外,还将讨论将TDCs集成到dSiPM和SPAD成像器中,并分析TDCs在不同生物医学成像应用中的当前结果。最后,介绍了TDCs在生物医学成像应用中的几个重要研究挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CMOS Time-to-Digital Converters for Biomedical Imaging Applications
Time-to-digital converters (TDCs) are high-performance mixed-signal circuits capable of timestamping events with sub-gate delay resolution. As a result of their high-performance, in recent years TDCs were integrated in complementary metal-oxide-semiconductor (CMOS) technology with highly sensitive photodetectors known as single-photon avalanche diodes (SPADs), to form digital silicon photomultipliers (dSiPMs) and SPAD imagers. Time-resolved SPAD-based sensors are capable of detecting the absorption of a single photon and timestamping it with picosecond resolution. As such, SPAD-based sensors are very useful in the field of biomedical imaging, using time-of-flight (ToF) information to produce data that can be used to reconstruct high-quality biological images. Additionally, the capability of integration in standard CMOS technologies, allows SPAD-based sensors to provide high-performance, while maintaining low cost. In this paper, we present an overview of fundamental TDC principles, and an analysis of state-of-the-art TDCs. Furthermore, the integration of TDCs into dSiPMs and SPAD imagers will be discussed, with an analysis of the current results of TDCs in different biomedical imaging applications. Finally, several important research challenges for TDCs in biomedical imaging applications are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Reviews in Biomedical Engineering
IEEE Reviews in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
31.70
自引率
0.60%
发文量
93
期刊介绍: IEEE Reviews in Biomedical Engineering (RBME) serves as a platform to review the state-of-the-art and trends in the interdisciplinary field of biomedical engineering, which encompasses engineering, life sciences, and medicine. The journal aims to consolidate research and reviews for members of all IEEE societies interested in biomedical engineering. Recognizing the demand for comprehensive reviews among authors of various IEEE journals, RBME addresses this need by receiving, reviewing, and publishing scholarly works under one umbrella. It covers a broad spectrum, from historical to modern developments in biomedical engineering and the integration of technologies from various IEEE societies into the life sciences and medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信