{"title":"快速部署主动脉瓣置换术:患者选择和特殊考虑。","authors":"Tomoki Sakata, Corazon De La Pena, Suguru Ohira","doi":"10.2147/VHRM.S374410","DOIUrl":null,"url":null,"abstract":"<p><p>Sutureless or rapid deployment valves in the setting of aortic valve replacement (AVR) is an emerging surgical technique using the transcatheter valve technology, which may lead to reduction in cross-clamp time and potentially better hemodynamics compared to a stented bioprosthetic valve. The absence of subannular pledgets results to excellent hemodynamic performance with reduced turbulent flow and larger effective orifice area. However, complications from both surgical and transcatheter AVR may still occur and impact survival. The incidence of paravalvular leakage and permanent pacemaker implantation are not low. Although technical modifications can improve these outcomes, there is a learning curve effect. Therefore, technical and anatomical considerations as well as better patient selection are paramount for better outcomes. In this review, we discuss the use of sutureless or rapid deployment valves in setting of (1) complex procedures, (2) minimally invasive AVR, and (3) small aortic annulus. The advantage of sutureless or rapid deployment valves in terms of mortality remains to be clarified; therefore, it is necessary to accumulate long-term outcomes in an appropriate patient cohort.</p>","PeriodicalId":23597,"journal":{"name":"Vascular Health and Risk Management","volume":"19 ","pages":"169-180"},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9c/b7/vhrm-19-169.PMC10066891.pdf","citationCount":"0","resultStr":"{\"title\":\"Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations.\",\"authors\":\"Tomoki Sakata, Corazon De La Pena, Suguru Ohira\",\"doi\":\"10.2147/VHRM.S374410\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Sutureless or rapid deployment valves in the setting of aortic valve replacement (AVR) is an emerging surgical technique using the transcatheter valve technology, which may lead to reduction in cross-clamp time and potentially better hemodynamics compared to a stented bioprosthetic valve. The absence of subannular pledgets results to excellent hemodynamic performance with reduced turbulent flow and larger effective orifice area. However, complications from both surgical and transcatheter AVR may still occur and impact survival. The incidence of paravalvular leakage and permanent pacemaker implantation are not low. Although technical modifications can improve these outcomes, there is a learning curve effect. Therefore, technical and anatomical considerations as well as better patient selection are paramount for better outcomes. In this review, we discuss the use of sutureless or rapid deployment valves in setting of (1) complex procedures, (2) minimally invasive AVR, and (3) small aortic annulus. The advantage of sutureless or rapid deployment valves in terms of mortality remains to be clarified; therefore, it is necessary to accumulate long-term outcomes in an appropriate patient cohort.</p>\",\"PeriodicalId\":23597,\"journal\":{\"name\":\"Vascular Health and Risk Management\",\"volume\":\"19 \",\"pages\":\"169-180\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9c/b7/vhrm-19-169.PMC10066891.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vascular Health and Risk Management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/VHRM.S374410\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular Health and Risk Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/VHRM.S374410","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations.
Sutureless or rapid deployment valves in the setting of aortic valve replacement (AVR) is an emerging surgical technique using the transcatheter valve technology, which may lead to reduction in cross-clamp time and potentially better hemodynamics compared to a stented bioprosthetic valve. The absence of subannular pledgets results to excellent hemodynamic performance with reduced turbulent flow and larger effective orifice area. However, complications from both surgical and transcatheter AVR may still occur and impact survival. The incidence of paravalvular leakage and permanent pacemaker implantation are not low. Although technical modifications can improve these outcomes, there is a learning curve effect. Therefore, technical and anatomical considerations as well as better patient selection are paramount for better outcomes. In this review, we discuss the use of sutureless or rapid deployment valves in setting of (1) complex procedures, (2) minimally invasive AVR, and (3) small aortic annulus. The advantage of sutureless or rapid deployment valves in terms of mortality remains to be clarified; therefore, it is necessary to accumulate long-term outcomes in an appropriate patient cohort.
期刊介绍:
An international, peer-reviewed journal of therapeutics and risk management, focusing on concise rapid reporting of clinical studies on the processes involved in the maintenance of vascular health; the monitoring, prevention, and treatment of vascular disease and its sequelae; and the involvement of metabolic disorders, particularly diabetes. In addition, the journal will also seek to define drug usage in terms of ultimate uptake and acceptance by the patient and healthcare professional.