Daijiro Hori, Takahiro Yamamoto, Naoyuki Kimura, Atsushi Yamaguchi
{"title":"接受 19 毫米 Mosaic 治疗的主动脉瓣狭窄患者的左心室重塑和长期预后。","authors":"Daijiro Hori, Takahiro Yamamoto, Naoyuki Kimura, Atsushi Yamaguchi","doi":"10.1007/s10047-023-01390-3","DOIUrl":null,"url":null,"abstract":"<p><p>Mosaic valve shows higher pressure gradient after aortic valve replacement compared to other same size labeled prostheses in postoperative echocardiogram. The purpose of this study was to evaluate the mid-term echocardiogram findings and long-term clinical outcomes of patients receiving a 19 mm Mosaic. Forty-six aortic stenosis patients receiving 19 mm Mosaic and 112 patients receiving either 19 mm Magna or Inspiris, who underwent mid-term follow-up echocardiogram were included in the study. Mid-term hemodynamic measurements evaluated by trans-thoracic echocardiogram and long-term outcomes were compared. Patients receiving Mosaic were significantly older (Mosaic: 76 ± 5.1 years vs. Magna/Inspiris: 74 ± 5.5 years, p = 0.046) and had smaller body surface area (Mosaic: 1.40 ± 0.114m<sup>2</sup> vs. Magna/Inspiris: 1.48 ± 0.143m<sup>2</sup>, p < 0.001). There were no significant differences in comorbidities and medications. Post-operative echocardiogram performed at 1 week after the surgery showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 38 ± 13.5 mmHg vs. Magna/Inspiris: 31 ± 10.7 mmHg, p = 0.002). Furthermore, mid-term echocardiogram follow-up performed at median duration of 53 ± 14.9 months after the surgery continuously showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 45 ± 15.6 mmHg vs. Magna/Inspiris: 32 ± 13.0 mmHg, p < 0.001). However, there were no significant difference in changes in left ventricular mass from baseline in both groups. Kaplan-Meyer curve also showed no difference in long-term mortality and major adverse cardiac and cerebrovascular event between the two groups. Although the pressure gradient across the valve evaluated by echocardiogram was higher in 19 mm Mosaic compared to 19 mm Magna/Inspiris, there were no significant differences in left ventricular remodeling and long-term outcomes between the two groups.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Left ventricular remodeling and long-term outcomes of aortic stenosis patients receiving 19 mm Mosaic.\",\"authors\":\"Daijiro Hori, Takahiro Yamamoto, Naoyuki Kimura, Atsushi Yamaguchi\",\"doi\":\"10.1007/s10047-023-01390-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Mosaic valve shows higher pressure gradient after aortic valve replacement compared to other same size labeled prostheses in postoperative echocardiogram. The purpose of this study was to evaluate the mid-term echocardiogram findings and long-term clinical outcomes of patients receiving a 19 mm Mosaic. Forty-six aortic stenosis patients receiving 19 mm Mosaic and 112 patients receiving either 19 mm Magna or Inspiris, who underwent mid-term follow-up echocardiogram were included in the study. Mid-term hemodynamic measurements evaluated by trans-thoracic echocardiogram and long-term outcomes were compared. Patients receiving Mosaic were significantly older (Mosaic: 76 ± 5.1 years vs. Magna/Inspiris: 74 ± 5.5 years, p = 0.046) and had smaller body surface area (Mosaic: 1.40 ± 0.114m<sup>2</sup> vs. Magna/Inspiris: 1.48 ± 0.143m<sup>2</sup>, p < 0.001). There were no significant differences in comorbidities and medications. Post-operative echocardiogram performed at 1 week after the surgery showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 38 ± 13.5 mmHg vs. Magna/Inspiris: 31 ± 10.7 mmHg, p = 0.002). Furthermore, mid-term echocardiogram follow-up performed at median duration of 53 ± 14.9 months after the surgery continuously showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 45 ± 15.6 mmHg vs. Magna/Inspiris: 32 ± 13.0 mmHg, p < 0.001). However, there were no significant difference in changes in left ventricular mass from baseline in both groups. Kaplan-Meyer curve also showed no difference in long-term mortality and major adverse cardiac and cerebrovascular event between the two groups. Although the pressure gradient across the valve evaluated by echocardiogram was higher in 19 mm Mosaic compared to 19 mm Magna/Inspiris, there were no significant differences in left ventricular remodeling and long-term outcomes between the two groups.</p>\",\"PeriodicalId\":15177,\"journal\":{\"name\":\"Journal of Artificial Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10047-023-01390-3\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01390-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/29 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Left ventricular remodeling and long-term outcomes of aortic stenosis patients receiving 19 mm Mosaic.
Mosaic valve shows higher pressure gradient after aortic valve replacement compared to other same size labeled prostheses in postoperative echocardiogram. The purpose of this study was to evaluate the mid-term echocardiogram findings and long-term clinical outcomes of patients receiving a 19 mm Mosaic. Forty-six aortic stenosis patients receiving 19 mm Mosaic and 112 patients receiving either 19 mm Magna or Inspiris, who underwent mid-term follow-up echocardiogram were included in the study. Mid-term hemodynamic measurements evaluated by trans-thoracic echocardiogram and long-term outcomes were compared. Patients receiving Mosaic were significantly older (Mosaic: 76 ± 5.1 years vs. Magna/Inspiris: 74 ± 5.5 years, p = 0.046) and had smaller body surface area (Mosaic: 1.40 ± 0.114m2 vs. Magna/Inspiris: 1.48 ± 0.143m2, p < 0.001). There were no significant differences in comorbidities and medications. Post-operative echocardiogram performed at 1 week after the surgery showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 38 ± 13.5 mmHg vs. Magna/Inspiris: 31 ± 10.7 mmHg, p = 0.002). Furthermore, mid-term echocardiogram follow-up performed at median duration of 53 ± 14.9 months after the surgery continuously showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 45 ± 15.6 mmHg vs. Magna/Inspiris: 32 ± 13.0 mmHg, p < 0.001). However, there were no significant difference in changes in left ventricular mass from baseline in both groups. Kaplan-Meyer curve also showed no difference in long-term mortality and major adverse cardiac and cerebrovascular event between the two groups. Although the pressure gradient across the valve evaluated by echocardiogram was higher in 19 mm Mosaic compared to 19 mm Magna/Inspiris, there were no significant differences in left ventricular remodeling and long-term outcomes between the two groups.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.