利用椅旁 CAD/CAM 系统,评估采用不同加工策略制作的氧化锆牙冠的凹槽内表面真实性和密合性。

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Jae-Hoon Kim, Hyeonjong Lee, Sung-Ae Son, Seoung-Jin Hong, Jeong-Kil Park
{"title":"利用椅旁 CAD/CAM 系统,评估采用不同加工策略制作的氧化锆牙冠的凹槽内表面真实性和密合性。","authors":"Jae-Hoon Kim, Hyeonjong Lee, Sung-Ae Son, Seoung-Jin Hong, Jeong-Kil Park","doi":"10.3290/j.ijcd.b3840499","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The present study aimed to evaluate the intaglio surface trueness and fit of zirconia crowns depending on the different machining strategies used with the Cerec system.</p><p><strong>Materials and methods: </strong>Thirty duplicate tooth models for a single zirconia crown were randomly assigned to three groups (n = 10) according to the machining mode used for fabrication: grinding, wet milling, and dry milling. The scan data of the final crowns were compared with their design data to evaluate the intaglio surface trueness. The marginal and internal fit were evaluated using a cross-sectional method. The time required for the machining and sintering processes was measured for each group.</p><p><strong>Results: </strong>The wet-milling group showed better trueness (root mean square: 13.8 ± 1.0 μm) than the grinding and dry-milling groups (P < 0.001). The marginal gap was greater in the grinding group (58.6 ± 28.9 μm) than that in the wet- and dry-milling groups (P < 0.001). The dry-milling group required the shortest time for the manufacturing process.</p><p><strong>Conclusion: </strong>All machining modes fabricated crowns with a clinically acceptable trueness and fit. However, the dry-milling mode was advantageous for the chairside CAD/CAM system with respect to time efficiency.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"191-198"},"PeriodicalIF":1.8000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the intaglio surface trueness and fit of zirconia crowns fabricated using different machining strategies with a chairside CAD/CAM system.\",\"authors\":\"Jae-Hoon Kim, Hyeonjong Lee, Sung-Ae Son, Seoung-Jin Hong, Jeong-Kil Park\",\"doi\":\"10.3290/j.ijcd.b3840499\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The present study aimed to evaluate the intaglio surface trueness and fit of zirconia crowns depending on the different machining strategies used with the Cerec system.</p><p><strong>Materials and methods: </strong>Thirty duplicate tooth models for a single zirconia crown were randomly assigned to three groups (n = 10) according to the machining mode used for fabrication: grinding, wet milling, and dry milling. The scan data of the final crowns were compared with their design data to evaluate the intaglio surface trueness. The marginal and internal fit were evaluated using a cross-sectional method. The time required for the machining and sintering processes was measured for each group.</p><p><strong>Results: </strong>The wet-milling group showed better trueness (root mean square: 13.8 ± 1.0 μm) than the grinding and dry-milling groups (P < 0.001). The marginal gap was greater in the grinding group (58.6 ± 28.9 μm) than that in the wet- and dry-milling groups (P < 0.001). The dry-milling group required the shortest time for the manufacturing process.</p><p><strong>Conclusion: </strong>All machining modes fabricated crowns with a clinically acceptable trueness and fit. However, the dry-milling mode was advantageous for the chairside CAD/CAM system with respect to time efficiency.</p>\",\"PeriodicalId\":48666,\"journal\":{\"name\":\"International Journal of Computerized Dentistry\",\"volume\":\"0 0\",\"pages\":\"191-198\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computerized Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ijcd.b3840499\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b3840499","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在根据 CEREC 系统使用的不同加工策略,评估氧化锆牙冠的凹面真实性和密合性:根据磨削、湿磨和干磨的加工模式,将单个氧化锆冠的 30 个重复牙齿模型随机分配到三组(n = 10)。将最终牙冠的扫描数据与其设计数据进行比较,以评估凹面的表面真实性。使用横截面法对边缘和内部配合进行了评估。测量了每组加工和烧结过程所需的时间:结果:湿铣组比磨削组和干铣组显示出更好的真实度(均方根值,13.8 ± 1.0 μm)(p < 0.001)。磨削组的边缘间隙(58.6 ± 28.9 μm)大于湿磨和干磨组(p < 0.001)。结论:所有加工模式都能制作出牙冠:结论:所有的加工模式都能制作出临床上可接受的真实度和密合度的牙冠。结论:所有加工模式都能制作出临床上可接受的真实度和密合度的牙冠,但就时间效率而言,干磨模式对椅旁 CAD/CAM 系统更有利。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the intaglio surface trueness and fit of zirconia crowns fabricated using different machining strategies with a chairside CAD/CAM system.

Aim: The present study aimed to evaluate the intaglio surface trueness and fit of zirconia crowns depending on the different machining strategies used with the Cerec system.

Materials and methods: Thirty duplicate tooth models for a single zirconia crown were randomly assigned to three groups (n = 10) according to the machining mode used for fabrication: grinding, wet milling, and dry milling. The scan data of the final crowns were compared with their design data to evaluate the intaglio surface trueness. The marginal and internal fit were evaluated using a cross-sectional method. The time required for the machining and sintering processes was measured for each group.

Results: The wet-milling group showed better trueness (root mean square: 13.8 ± 1.0 μm) than the grinding and dry-milling groups (P < 0.001). The marginal gap was greater in the grinding group (58.6 ± 28.9 μm) than that in the wet- and dry-milling groups (P < 0.001). The dry-milling group required the shortest time for the manufacturing process.

Conclusion: All machining modes fabricated crowns with a clinically acceptable trueness and fit. However, the dry-milling mode was advantageous for the chairside CAD/CAM system with respect to time efficiency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信