{"title":"鼻咽癌放射治疗质量控制实践中建立可重复性的统计过程控制工具","authors":"S. Xu, Z. Li, J. Hu, J. Zhang","doi":"10.52547/ijrr.20.2.7","DOIUrl":null,"url":null,"abstract":"Background : This study aims to perform quality control (QC) practices for setup reproducibility during radiotherapy for nasopharyngeal carcinoma (NPC) using statistical process control (SPC) tools. Materials and Methods : A total of 480 fractional images from 48 NPC patients with the first 10 fractions of the treatment were collected. In QC practices, setup errors were described using the histogram and normal curve, cumulative frequencies of absolute setup errors and 3D Euclidean Distance (E u ) were analyzed; the X ̅ - S chart and process capability index (Cpk) with the variable E u were utilized to identify whether the outlier occurred and to evaluate the QC process. Results : The translational setup error distributions were almost normal in Lateral, Longitudinal and Vertical directions and were narrower in Lateral and Vertical directions. Vertical translational errors and E u with a larger magnitude sag appeared the most frequently. Between the couch sag and no sag, the E u mean of 7 to 7 NPC patients with the same 3 patients was out of control and the standard deviation of E u of nil to 2 patients was outlier based on the X ̅ - S chart, and the Cpk was 1.05 and 1.36 respectively, when the specification limit of translational errors was ±3 mm. Conclusion : Daily imaging is necessary to increase setup reproducibility for NPC patients and more measures should be taken to facilitate quality assurance procedures. SPC is better applied to QC practices depending on the reliable data and the acceptable tolerance levels in","PeriodicalId":48815,"journal":{"name":"International Journal of Radiation Research","volume":"68 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Statistical process control tools for setup reproducibility in quality control practices during nasopharyngeal carcinoma radiotherapy\",\"authors\":\"S. Xu, Z. Li, J. Hu, J. Zhang\",\"doi\":\"10.52547/ijrr.20.2.7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background : This study aims to perform quality control (QC) practices for setup reproducibility during radiotherapy for nasopharyngeal carcinoma (NPC) using statistical process control (SPC) tools. Materials and Methods : A total of 480 fractional images from 48 NPC patients with the first 10 fractions of the treatment were collected. In QC practices, setup errors were described using the histogram and normal curve, cumulative frequencies of absolute setup errors and 3D Euclidean Distance (E u ) were analyzed; the X ̅ - S chart and process capability index (Cpk) with the variable E u were utilized to identify whether the outlier occurred and to evaluate the QC process. Results : The translational setup error distributions were almost normal in Lateral, Longitudinal and Vertical directions and were narrower in Lateral and Vertical directions. Vertical translational errors and E u with a larger magnitude sag appeared the most frequently. Between the couch sag and no sag, the E u mean of 7 to 7 NPC patients with the same 3 patients was out of control and the standard deviation of E u of nil to 2 patients was outlier based on the X ̅ - S chart, and the Cpk was 1.05 and 1.36 respectively, when the specification limit of translational errors was ±3 mm. Conclusion : Daily imaging is necessary to increase setup reproducibility for NPC patients and more measures should be taken to facilitate quality assurance procedures. SPC is better applied to QC practices depending on the reliable data and the acceptable tolerance levels in\",\"PeriodicalId\":48815,\"journal\":{\"name\":\"International Journal of Radiation Research\",\"volume\":\"68 1\",\"pages\":\"\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2022-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Radiation Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.52547/ijrr.20.2.7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52547/ijrr.20.2.7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Statistical process control tools for setup reproducibility in quality control practices during nasopharyngeal carcinoma radiotherapy
Background : This study aims to perform quality control (QC) practices for setup reproducibility during radiotherapy for nasopharyngeal carcinoma (NPC) using statistical process control (SPC) tools. Materials and Methods : A total of 480 fractional images from 48 NPC patients with the first 10 fractions of the treatment were collected. In QC practices, setup errors were described using the histogram and normal curve, cumulative frequencies of absolute setup errors and 3D Euclidean Distance (E u ) were analyzed; the X ̅ - S chart and process capability index (Cpk) with the variable E u were utilized to identify whether the outlier occurred and to evaluate the QC process. Results : The translational setup error distributions were almost normal in Lateral, Longitudinal and Vertical directions and were narrower in Lateral and Vertical directions. Vertical translational errors and E u with a larger magnitude sag appeared the most frequently. Between the couch sag and no sag, the E u mean of 7 to 7 NPC patients with the same 3 patients was out of control and the standard deviation of E u of nil to 2 patients was outlier based on the X ̅ - S chart, and the Cpk was 1.05 and 1.36 respectively, when the specification limit of translational errors was ±3 mm. Conclusion : Daily imaging is necessary to increase setup reproducibility for NPC patients and more measures should be taken to facilitate quality assurance procedures. SPC is better applied to QC practices depending on the reliable data and the acceptable tolerance levels in
期刊介绍:
International Journal of Radiation Research (IJRR) publishes original scientific research and clinical investigations related to radiation oncology, radiation biology, and Medical and health physics. The clinical studies submitted for publication include experimental studies of combined modality treatment, especially chemoradiotherapy approaches, and relevant innovations in hyperthermia, brachytherapy, high LET irradiation, nuclear medicine, dosimetry, tumor imaging, radiation treatment planning, radiosensitizers, and radioprotectors. All manuscripts must pass stringent peer-review and only papers that are rated of high scientific quality are accepted.