臂围在43到50厘米之间的人的血压测量装置验证研究的合适参考袖带标准

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Paolo Palatini, Claudio Fania, Elisabetta Benetti, Francesca Saladini, Francesca Battista, Andrea Ermolao
{"title":"臂围在43到50厘米之间的人的血压测量装置验证研究的合适参考袖带标准","authors":"Paolo Palatini,&nbsp;Claudio Fania,&nbsp;Elisabetta Benetti,&nbsp;Francesca Saladini,&nbsp;Francesca Battista,&nbsp;Andrea Ermolao","doi":"10.1097/MBP.0000000000000630","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Recommendations about the dimensions of the reference cuff for device validations in people with arm size >42 cm are still unavailable. The aim of this study was to identify the criteria for an appropriate reference cuff for validation studies in people with upper arm circumference between 43 and 50 cm.</p><p><strong>Methods: </strong>In 20 adults with upper arm circumference between 43 and 50 cm (X-large group), 34 subjects with arm circumference between 37 and 42 cm and 78 subjects with arm circumference <37 cm cylindrical and tronco-conical cuffs were compared. In all participants, the pressure transmitted to the arm under the two cuffs was measured using a paper-thin pressure sensor.</p><p><strong>Results: </strong>In the X-large group, all participants had an arm slant angle <86.0°. In this group, the difference between the pressure detected on the arm surface with the sensor using the cylindrical versus the tronco-conical cuff (13.5 mmHg) was larger than in the group with an arm circumference of 37-to 42 cm and the group with a circumference <37 cm (3.7 and 0.6 mmHg, respectively, P  < 0.001 versus both). In the whole sample, the between-cuff pressure difference was proportional to the conical shape of the arm ( P  < 0.001).</p><p><strong>Conclusions: </strong>These data suggest that in people with arm size between 43 and 50 cm the reference cuff for validation studies should have a conical shape with an 84-85° slant angle. To comply with current guidelines, an 18.5 × 37.0 cm bladder should be used which would allow proper cuffing in the large majority of subjects.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Criteria for a suitable reference cuff for validation studies of blood pressure measuring devices in people with arm circumference between 43 and 50 cm.\",\"authors\":\"Paolo Palatini,&nbsp;Claudio Fania,&nbsp;Elisabetta Benetti,&nbsp;Francesca Saladini,&nbsp;Francesca Battista,&nbsp;Andrea Ermolao\",\"doi\":\"10.1097/MBP.0000000000000630\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Recommendations about the dimensions of the reference cuff for device validations in people with arm size >42 cm are still unavailable. The aim of this study was to identify the criteria for an appropriate reference cuff for validation studies in people with upper arm circumference between 43 and 50 cm.</p><p><strong>Methods: </strong>In 20 adults with upper arm circumference between 43 and 50 cm (X-large group), 34 subjects with arm circumference between 37 and 42 cm and 78 subjects with arm circumference <37 cm cylindrical and tronco-conical cuffs were compared. In all participants, the pressure transmitted to the arm under the two cuffs was measured using a paper-thin pressure sensor.</p><p><strong>Results: </strong>In the X-large group, all participants had an arm slant angle <86.0°. In this group, the difference between the pressure detected on the arm surface with the sensor using the cylindrical versus the tronco-conical cuff (13.5 mmHg) was larger than in the group with an arm circumference of 37-to 42 cm and the group with a circumference <37 cm (3.7 and 0.6 mmHg, respectively, P  < 0.001 versus both). In the whole sample, the between-cuff pressure difference was proportional to the conical shape of the arm ( P  < 0.001).</p><p><strong>Conclusions: </strong>These data suggest that in people with arm size between 43 and 50 cm the reference cuff for validation studies should have a conical shape with an 84-85° slant angle. To comply with current guidelines, an 18.5 × 37.0 cm bladder should be used which would allow proper cuffing in the large majority of subjects.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBP.0000000000000630\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000630","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

目的:对于臂长>42 cm的患者,关于设备验证的参考袖带尺寸的建议仍然没有。本研究的目的是为上臂围在43至50厘米之间的人群的验证研究确定合适的参考袖带的标准。方法:20名上臂围为43 - 50 cm的成人(X-large组),34名上臂围为37 - 42 cm的成人(X-large组),78名上臂围为37 - 42 cm的成人(X-large组)。结果:在X-large组中,所有参与者的上臂均呈倾斜角度。结论:这些数据表明,在臂围为43 - 50 cm的人群中,验证研究的参考袖带应为倾斜角度为84-85°的圆锥形。根据现行指南,应使用18.5 × 37.0 cm的膀胱,这将允许大多数受试者进行适当的穿刺。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Criteria for a suitable reference cuff for validation studies of blood pressure measuring devices in people with arm circumference between 43 and 50 cm.

Objective: Recommendations about the dimensions of the reference cuff for device validations in people with arm size >42 cm are still unavailable. The aim of this study was to identify the criteria for an appropriate reference cuff for validation studies in people with upper arm circumference between 43 and 50 cm.

Methods: In 20 adults with upper arm circumference between 43 and 50 cm (X-large group), 34 subjects with arm circumference between 37 and 42 cm and 78 subjects with arm circumference <37 cm cylindrical and tronco-conical cuffs were compared. In all participants, the pressure transmitted to the arm under the two cuffs was measured using a paper-thin pressure sensor.

Results: In the X-large group, all participants had an arm slant angle <86.0°. In this group, the difference between the pressure detected on the arm surface with the sensor using the cylindrical versus the tronco-conical cuff (13.5 mmHg) was larger than in the group with an arm circumference of 37-to 42 cm and the group with a circumference <37 cm (3.7 and 0.6 mmHg, respectively, P  < 0.001 versus both). In the whole sample, the between-cuff pressure difference was proportional to the conical shape of the arm ( P  < 0.001).

Conclusions: These data suggest that in people with arm size between 43 and 50 cm the reference cuff for validation studies should have a conical shape with an 84-85° slant angle. To comply with current guidelines, an 18.5 × 37.0 cm bladder should be used which would allow proper cuffing in the large majority of subjects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信