{"title":"陶瓷冠与氧化锆或聚醚酮框架的承载能力比较。","authors":"Özge Seckin, Ceyda Akin, Mutlu Özcan","doi":"10.3290/j.ijcd.b3774269","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of the present study was to compare the load bearing capacity of monolithic or bilayered single crowns with zirconia or polyetherketoneketone frameworks designed and fabricated using CAD/CAM systems.</p><p><strong>Materials and methods: </strong>Cr-Co-based metal dies (n = 60) were duplicated from an extracted and prepared premolar and then restored with different CAD/CAM materials. The specimens were divided into five groups (n = 12) according to the type of materials: group S: monolithic zirconia-reinforced lithium disilicate; group ZI: bilayered zirconia framework with lithium disilicate; group ZE: bilayered zirconia framework with resin-infiltrated hybrid ceramic; group PI: bilayered polyetherketoneketone (PEKK) framework with lithium disilicate; group PE: bilayered PEKK framework with resin-infiltrated hybrid ceramic. The crown specimens were cemented on Cr-Co metal dies with a resin cement (Multilink N). The specimens were subjected to cyclic mechanical loading followed by load bearing testing. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (α = 0.05).</p><p><strong>Results: </strong>The monolithic crowns in group S (1930 ± 452.18 N) presented significantly higher load bearing capacity than those of the other groups (P < 0.05). This was followed by group ZI (1165.41 ± 264.04 N). The remaining groups demonstrated comparable results. Failure types were more frequent in all zirconia specimens that included veneering ceramic.</p><p><strong>Conclusions: </strong>Monolithic zirconia-reinforced lithium disilicate CAD/CAM ceramics showed superior load bearing capacity compared with all other bilayered counterparts. All CAD/CAM materials tested remarkably exceeded the average occlusal force in the posterior region.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"227-236"},"PeriodicalIF":1.8000,"publicationDate":"2023-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of load bearing capacity of ceramic crowns with zirconia or polyetherketoneketone frameworks.\",\"authors\":\"Özge Seckin, Ceyda Akin, Mutlu Özcan\",\"doi\":\"10.3290/j.ijcd.b3774269\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The aim of the present study was to compare the load bearing capacity of monolithic or bilayered single crowns with zirconia or polyetherketoneketone frameworks designed and fabricated using CAD/CAM systems.</p><p><strong>Materials and methods: </strong>Cr-Co-based metal dies (n = 60) were duplicated from an extracted and prepared premolar and then restored with different CAD/CAM materials. The specimens were divided into five groups (n = 12) according to the type of materials: group S: monolithic zirconia-reinforced lithium disilicate; group ZI: bilayered zirconia framework with lithium disilicate; group ZE: bilayered zirconia framework with resin-infiltrated hybrid ceramic; group PI: bilayered polyetherketoneketone (PEKK) framework with lithium disilicate; group PE: bilayered PEKK framework with resin-infiltrated hybrid ceramic. The crown specimens were cemented on Cr-Co metal dies with a resin cement (Multilink N). The specimens were subjected to cyclic mechanical loading followed by load bearing testing. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (α = 0.05).</p><p><strong>Results: </strong>The monolithic crowns in group S (1930 ± 452.18 N) presented significantly higher load bearing capacity than those of the other groups (P < 0.05). This was followed by group ZI (1165.41 ± 264.04 N). The remaining groups demonstrated comparable results. Failure types were more frequent in all zirconia specimens that included veneering ceramic.</p><p><strong>Conclusions: </strong>Monolithic zirconia-reinforced lithium disilicate CAD/CAM ceramics showed superior load bearing capacity compared with all other bilayered counterparts. All CAD/CAM materials tested remarkably exceeded the average occlusal force in the posterior region.</p>\",\"PeriodicalId\":48666,\"journal\":{\"name\":\"International Journal of Computerized Dentistry\",\"volume\":\"0 0\",\"pages\":\"227-236\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computerized Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ijcd.b3774269\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b3774269","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Comparison of load bearing capacity of ceramic crowns with zirconia or polyetherketoneketone frameworks.
Aim: The aim of the present study was to compare the load bearing capacity of monolithic or bilayered single crowns with zirconia or polyetherketoneketone frameworks designed and fabricated using CAD/CAM systems.
Materials and methods: Cr-Co-based metal dies (n = 60) were duplicated from an extracted and prepared premolar and then restored with different CAD/CAM materials. The specimens were divided into five groups (n = 12) according to the type of materials: group S: monolithic zirconia-reinforced lithium disilicate; group ZI: bilayered zirconia framework with lithium disilicate; group ZE: bilayered zirconia framework with resin-infiltrated hybrid ceramic; group PI: bilayered polyetherketoneketone (PEKK) framework with lithium disilicate; group PE: bilayered PEKK framework with resin-infiltrated hybrid ceramic. The crown specimens were cemented on Cr-Co metal dies with a resin cement (Multilink N). The specimens were subjected to cyclic mechanical loading followed by load bearing testing. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (α = 0.05).
Results: The monolithic crowns in group S (1930 ± 452.18 N) presented significantly higher load bearing capacity than those of the other groups (P < 0.05). This was followed by group ZI (1165.41 ± 264.04 N). The remaining groups demonstrated comparable results. Failure types were more frequent in all zirconia specimens that included veneering ceramic.
Conclusions: Monolithic zirconia-reinforced lithium disilicate CAD/CAM ceramics showed superior load bearing capacity compared with all other bilayered counterparts. All CAD/CAM materials tested remarkably exceeded the average occlusal force in the posterior region.
期刊介绍:
This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.