使用QUADAS-2评估研究质量和使用Stata / MP v.16进行荟萃分析对伊朗医院Covid - 19相关检测结果的医学评价软件

H. Danesh, S. R. Ghasabeh, R. Rounasi, E. Zarepur, A. Abdolrazaghnejad
{"title":"使用QUADAS-2评估研究质量和使用Stata / MP v.16进行荟萃分析对伊朗医院Covid - 19相关检测结果的医学评价软件","authors":"H. Danesh, S. R. Ghasabeh, R. Rounasi, E. Zarepur, A. Abdolrazaghnejad","doi":"10.26655/jmchemsci.2022.2.10","DOIUrl":null,"url":null,"abstract":"The aim of current study was to evaluate the outcome of some laboratory tests and accuracy of diagnostic tests for patients with COVID-19. The QUADAS-2 tool was utilized to quality assessment of diagnostic accuracy studies. For data extraction, two reviewers blind and independently extracted data from and full text of studies that included. 95% confidence interval for effect size with fixed effect model and Inver-variance method were calculated. Meta-analysis was performed using Stata/MP v.16 software. 469 studies were reviewed, of which the full text of 52 studies was reviewed and finally twenty-two studies were selected for meta-analysis. Mean differences of Alanine transaminase was 3.40 U/L (MD, 95% CI -2.45, 9.25), correlation between Alanine transaminase and severe COVID-19 was not significantly. Stool, feces, rectal swabs 25% (ES, 95% CI 0.32, 0.82), Urine 1% (ES, 95% CI 0.05, 0.58), overall sensitivity of PCR for detection of COVID-19 was 44% (ES, 95% CI 0.19, 0.68), less sensitive observerd when PCR detection of COVID-19. Evidence revealed that at the time of admission of patients with COVID-19, a specific laboratory model can be used to perform relevant tests and make decisions about patients. PCR using sputum samples was highly sensitive for detecting COVID-19 and after that computed tomography of the chest was identified with high sensitivity. © 2022 by SPC (Sami Publishing Company).","PeriodicalId":16365,"journal":{"name":"Journal of Medicinal and Chemical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Medical Evaluation of Test Results Related to Covid 19 in Iranian Hospitals Using QUADAS-2 to Evaluate the Quality of Studies and Meta-Analysis Using Stata / MP v.16 Software\",\"authors\":\"H. Danesh, S. R. Ghasabeh, R. Rounasi, E. Zarepur, A. Abdolrazaghnejad\",\"doi\":\"10.26655/jmchemsci.2022.2.10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of current study was to evaluate the outcome of some laboratory tests and accuracy of diagnostic tests for patients with COVID-19. The QUADAS-2 tool was utilized to quality assessment of diagnostic accuracy studies. For data extraction, two reviewers blind and independently extracted data from and full text of studies that included. 95% confidence interval for effect size with fixed effect model and Inver-variance method were calculated. Meta-analysis was performed using Stata/MP v.16 software. 469 studies were reviewed, of which the full text of 52 studies was reviewed and finally twenty-two studies were selected for meta-analysis. Mean differences of Alanine transaminase was 3.40 U/L (MD, 95% CI -2.45, 9.25), correlation between Alanine transaminase and severe COVID-19 was not significantly. Stool, feces, rectal swabs 25% (ES, 95% CI 0.32, 0.82), Urine 1% (ES, 95% CI 0.05, 0.58), overall sensitivity of PCR for detection of COVID-19 was 44% (ES, 95% CI 0.19, 0.68), less sensitive observerd when PCR detection of COVID-19. Evidence revealed that at the time of admission of patients with COVID-19, a specific laboratory model can be used to perform relevant tests and make decisions about patients. PCR using sputum samples was highly sensitive for detecting COVID-19 and after that computed tomography of the chest was identified with high sensitivity. © 2022 by SPC (Sami Publishing Company).\",\"PeriodicalId\":16365,\"journal\":{\"name\":\"Journal of Medicinal and Chemical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medicinal and Chemical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26655/jmchemsci.2022.2.10\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medicinal and Chemical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26655/jmchemsci.2022.2.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究的目的是评估一些实验室检查的结果和COVID-19患者诊断检查的准确性。QUADAS-2工具用于诊断准确性研究的质量评估。在数据提取方面,两位审稿人采用盲法,独立地从纳入的研究中提取数据和全文。用固定效应模型和反方差法计算了效应大小的95%置信区间。采用Stata/MP v.16软件进行meta分析。共对469项研究进行综述,其中52项研究的全文进行综述,最后选取22项研究进行meta分析。谷丙转氨酶的平均差异为3.40 U/L (MD, 95% CI -2.45, 9.25),谷丙转氨酶与重症COVID-19的相关性无统计学意义。粪便、粪便、直肠拭子25%(可信区间,95% CI 0.32, 0.82),尿液1%(可信区间,95% CI 0.05, 0.58), PCR检测COVID-19的总灵敏度为44%(可信区间,95% CI 0.19, 0.68), PCR检测COVID-19时敏感性较低。有证据表明,在新冠肺炎患者入院时,可以使用特定的实验室模型进行相关测试并做出有关患者的决策。痰标本PCR检测COVID-19灵敏度高,胸部ct检测灵敏度高。©2022 by SPC (Sami Publishing Company)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Medical Evaluation of Test Results Related to Covid 19 in Iranian Hospitals Using QUADAS-2 to Evaluate the Quality of Studies and Meta-Analysis Using Stata / MP v.16 Software
The aim of current study was to evaluate the outcome of some laboratory tests and accuracy of diagnostic tests for patients with COVID-19. The QUADAS-2 tool was utilized to quality assessment of diagnostic accuracy studies. For data extraction, two reviewers blind and independently extracted data from and full text of studies that included. 95% confidence interval for effect size with fixed effect model and Inver-variance method were calculated. Meta-analysis was performed using Stata/MP v.16 software. 469 studies were reviewed, of which the full text of 52 studies was reviewed and finally twenty-two studies were selected for meta-analysis. Mean differences of Alanine transaminase was 3.40 U/L (MD, 95% CI -2.45, 9.25), correlation between Alanine transaminase and severe COVID-19 was not significantly. Stool, feces, rectal swabs 25% (ES, 95% CI 0.32, 0.82), Urine 1% (ES, 95% CI 0.05, 0.58), overall sensitivity of PCR for detection of COVID-19 was 44% (ES, 95% CI 0.19, 0.68), less sensitive observerd when PCR detection of COVID-19. Evidence revealed that at the time of admission of patients with COVID-19, a specific laboratory model can be used to perform relevant tests and make decisions about patients. PCR using sputum samples was highly sensitive for detecting COVID-19 and after that computed tomography of the chest was identified with high sensitivity. © 2022 by SPC (Sami Publishing Company).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信