3-1三维打印引导下经皮治疗功能性主动脉弓中断

M. Y, L. L, Zhai M, M. Y, J. P., L. Y, Yang J
{"title":"3-1三维打印引导下经皮治疗功能性主动脉弓中断","authors":"M. Y, L. L, Zhai M, M. Y, J. P., L. Y, Yang J","doi":"10.26420/austinjclincardiolog.2022.1097","DOIUrl":null,"url":null,"abstract":"Functional interrupted aortic arch is a congenital malformation characterized by a complete separation between the ascending aorta and the descending aorta. Untreated patients are in danger of having late complications including cerebral hemorrhage, aneurysm formation, and aortic regurgitation. Traditionally, classical surgical therapies included bypass grafting or orthotopic repair. Herein, we report a simplified percutaneous therapy for functional interrupted aortic arch with a retrograde crossing technique and without an incremental-sized expandable balloon. With the guidance of 3-dimensional printing, percutaneous treatment with a covered stent is a feasible, safe, and effective alternative to surgery with excellent short- and midterm results in selected patients with favorable anatomy.","PeriodicalId":90445,"journal":{"name":"Austin journal of clinical cardiology","volume":"34 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Percutaneous Therapy of Functional Interrupted Aortic Arch with 3-1 Dimensional Printing Guidance\",\"authors\":\"M. Y, L. L, Zhai M, M. Y, J. P., L. Y, Yang J\",\"doi\":\"10.26420/austinjclincardiolog.2022.1097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Functional interrupted aortic arch is a congenital malformation characterized by a complete separation between the ascending aorta and the descending aorta. Untreated patients are in danger of having late complications including cerebral hemorrhage, aneurysm formation, and aortic regurgitation. Traditionally, classical surgical therapies included bypass grafting or orthotopic repair. Herein, we report a simplified percutaneous therapy for functional interrupted aortic arch with a retrograde crossing technique and without an incremental-sized expandable balloon. With the guidance of 3-dimensional printing, percutaneous treatment with a covered stent is a feasible, safe, and effective alternative to surgery with excellent short- and midterm results in selected patients with favorable anatomy.\",\"PeriodicalId\":90445,\"journal\":{\"name\":\"Austin journal of clinical cardiology\",\"volume\":\"34 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Austin journal of clinical cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26420/austinjclincardiolog.2022.1097\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Austin journal of clinical cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/austinjclincardiolog.2022.1097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

功能性主动脉弓中断是一种先天性畸形,其特征是升主动脉和降主动脉之间完全分离。未经治疗的患者有发生晚期并发症的危险,包括脑出血、动脉瘤形成和主动脉反流。传统上,经典的手术治疗包括旁路移植术或原位修复。在此,我们报告了一种简化的经皮治疗功能性主动脉弓中断的方法,采用逆行交叉技术,无需增量大小的可膨胀球囊。在三维打印技术的指导下,经皮支架治疗是一种可行、安全、有效的替代手术的方法,在一些解剖结构良好的患者中具有良好的短期和中期效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Percutaneous Therapy of Functional Interrupted Aortic Arch with 3-1 Dimensional Printing Guidance
Functional interrupted aortic arch is a congenital malformation characterized by a complete separation between the ascending aorta and the descending aorta. Untreated patients are in danger of having late complications including cerebral hemorrhage, aneurysm formation, and aortic regurgitation. Traditionally, classical surgical therapies included bypass grafting or orthotopic repair. Herein, we report a simplified percutaneous therapy for functional interrupted aortic arch with a retrograde crossing technique and without an incremental-sized expandable balloon. With the guidance of 3-dimensional printing, percutaneous treatment with a covered stent is a feasible, safe, and effective alternative to surgery with excellent short- and midterm results in selected patients with favorable anatomy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信