{"title":"双硅光弹性调制器短波FIR激光偏振计的性能评价","authors":"T. Akiyama, K. Kawahata, S. Okajima, K. Nakayama","doi":"10.1080/10519990902884522","DOIUrl":null,"url":null,"abstract":"Measurement of an internal magnetic field distribution in magnetically confined fusion devices is indispensable for both understanding the plasma physics and controlling plasmas. A polari-interferometer based on the Faraday effect has been used for such a purpose. This paper describes performance evaluations of a part of the polarimeter with photoelastic modulators (PEMs) of the short-wavelength far-infrared (FIR) laser polari-interferometer. The wavelengths of the light source are 57.2 and 47.7 μ m, which are suitable for a high-density operation and large fusion devices. The PEM for the FIR region is newly developed with high-resistive silicon in which absorption of the FIR laser is small. The polarization angle is successfully measured and an angle resolution of 0.01° with a time resolution of 1 ms is achieved. A drift of the baseline of about 0.1° for 1000 s is observed and is found to be caused by changes in the room temperature.","PeriodicalId":54600,"journal":{"name":"Plasma Devices and Operations","volume":"45 1","pages":"117 - 125"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of short-wavelength FIR laser polarimeter with dual silicon photoelastic modulators\",\"authors\":\"T. Akiyama, K. Kawahata, S. Okajima, K. Nakayama\",\"doi\":\"10.1080/10519990902884522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement of an internal magnetic field distribution in magnetically confined fusion devices is indispensable for both understanding the plasma physics and controlling plasmas. A polari-interferometer based on the Faraday effect has been used for such a purpose. This paper describes performance evaluations of a part of the polarimeter with photoelastic modulators (PEMs) of the short-wavelength far-infrared (FIR) laser polari-interferometer. The wavelengths of the light source are 57.2 and 47.7 μ m, which are suitable for a high-density operation and large fusion devices. The PEM for the FIR region is newly developed with high-resistive silicon in which absorption of the FIR laser is small. The polarization angle is successfully measured and an angle resolution of 0.01° with a time resolution of 1 ms is achieved. A drift of the baseline of about 0.1° for 1000 s is observed and is found to be caused by changes in the room temperature.\",\"PeriodicalId\":54600,\"journal\":{\"name\":\"Plasma Devices and Operations\",\"volume\":\"45 1\",\"pages\":\"117 - 125\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plasma Devices and Operations\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10519990902884522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Devices and Operations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10519990902884522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance evaluation of short-wavelength FIR laser polarimeter with dual silicon photoelastic modulators
Measurement of an internal magnetic field distribution in magnetically confined fusion devices is indispensable for both understanding the plasma physics and controlling plasmas. A polari-interferometer based on the Faraday effect has been used for such a purpose. This paper describes performance evaluations of a part of the polarimeter with photoelastic modulators (PEMs) of the short-wavelength far-infrared (FIR) laser polari-interferometer. The wavelengths of the light source are 57.2 and 47.7 μ m, which are suitable for a high-density operation and large fusion devices. The PEM for the FIR region is newly developed with high-resistive silicon in which absorption of the FIR laser is small. The polarization angle is successfully measured and an angle resolution of 0.01° with a time resolution of 1 ms is achieved. A drift of the baseline of about 0.1° for 1000 s is observed and is found to be caused by changes in the room temperature.