生物斑点血流法用于视网膜血流诊断

Y. Aizu, T. Asakura, K. Ogino, T. Sugita, Yasuyuki Suzuki, K. Masuda
{"title":"生物斑点血流法用于视网膜血流诊断","authors":"Y. Aizu, T. Asakura, K. Ogino, T. Sugita, Yasuyuki Suzuki, K. Masuda","doi":"10.1002/1361-6374(199612)4:4<254::AID-BIO4>3.0.CO;2-7","DOIUrl":null,"url":null,"abstract":"Bio-speckle flowmetry for measuring the retinal blood flow velocity is described. The measuring principle is briefly discussed in comparison with the laser Doppler method. The basic properties of the photon correlation measurements including reproducibility were experimentally investigated with a rotating ground glass disk and for the normal human retina. The error was estimated to be less than 20% for in vivo measurements. By using a glass capillary model, the reciprocal of correlation time was calibrated to the mean flow velocity with a consideration of the effects of the vessel diameter and the background reflectance. The blood flow volume rate in the human retina was estimated by using the calibrated velocity and the vessel diameter. The results compared well with those reported in the literature, and show the usefulness of this flowmetry for clinical diagnostic purposes.","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1996-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"Bio-speckle flowmetry for retinal blood flow diagnostics\",\"authors\":\"Y. Aizu, T. Asakura, K. Ogino, T. Sugita, Yasuyuki Suzuki, K. Masuda\",\"doi\":\"10.1002/1361-6374(199612)4:4<254::AID-BIO4>3.0.CO;2-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bio-speckle flowmetry for measuring the retinal blood flow velocity is described. The measuring principle is briefly discussed in comparison with the laser Doppler method. The basic properties of the photon correlation measurements including reproducibility were experimentally investigated with a rotating ground glass disk and for the normal human retina. The error was estimated to be less than 20% for in vivo measurements. By using a glass capillary model, the reciprocal of correlation time was calibrated to the mean flow velocity with a consideration of the effects of the vessel diameter and the background reflectance. The blood flow volume rate in the human retina was estimated by using the calibrated velocity and the vessel diameter. The results compared well with those reported in the literature, and show the usefulness of this flowmetry for clinical diagnostic purposes.\",\"PeriodicalId\":100176,\"journal\":{\"name\":\"Bioimaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioimaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/1361-6374(199612)4:4<254::AID-BIO4>3.0.CO;2-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioimaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/1361-6374(199612)4:4<254::AID-BIO4>3.0.CO;2-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

描述了用于测量视网膜血流速度的生物散斑血流法。简要讨论了测量原理,并与激光多普勒法进行了比较。用旋转磨砂玻璃盘和正常人视网膜实验研究了光子相关测量的基本性质,包括再现性。体内测量的误差估计小于20%。利用玻璃毛细管模型,在考虑血管直径和背景反射率影响的情况下,将相关时间倒数标定为平均流速。利用标定后的流速和血管直径来估计人视网膜的血流体积率。结果与文献报道的结果相比较,显示了该血流法在临床诊断中的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bio-speckle flowmetry for retinal blood flow diagnostics
Bio-speckle flowmetry for measuring the retinal blood flow velocity is described. The measuring principle is briefly discussed in comparison with the laser Doppler method. The basic properties of the photon correlation measurements including reproducibility were experimentally investigated with a rotating ground glass disk and for the normal human retina. The error was estimated to be less than 20% for in vivo measurements. By using a glass capillary model, the reciprocal of correlation time was calibrated to the mean flow velocity with a consideration of the effects of the vessel diameter and the background reflectance. The blood flow volume rate in the human retina was estimated by using the calibrated velocity and the vessel diameter. The results compared well with those reported in the literature, and show the usefulness of this flowmetry for clinical diagnostic purposes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信