{"title":"一种监测非铁磁性金属中杂质的感应方法","authors":"Gennadii L. Losev, A. Mamykin","doi":"10.17072/1994-3598-2022-1-38-43","DOIUrl":null,"url":null,"abstract":"The paper presents a method for electromagnetic measurements of the chemical impurities’ con-centration in samples of non-ferrous metals. The principle of measurements is described and the in-fluence of the inaccuracy in geometric dimensions of the analyzed metal volume on the measure-ment error is established. The proposed measurement method was tested on model samples of a tin-lead alloy with an admixture of copper particles of various mass concentrations. For the select-ed combination of the analyzed metal and impurities a calibration curve of the sensor was ob-tained in the concentration range from 0 to 10%.","PeriodicalId":41257,"journal":{"name":"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History","volume":"54 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An inductive method for monitoring impurities in non-ferromagnetic metals\",\"authors\":\"Gennadii L. Losev, A. Mamykin\",\"doi\":\"10.17072/1994-3598-2022-1-38-43\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents a method for electromagnetic measurements of the chemical impurities’ con-centration in samples of non-ferrous metals. The principle of measurements is described and the in-fluence of the inaccuracy in geometric dimensions of the analyzed metal volume on the measure-ment error is established. The proposed measurement method was tested on model samples of a tin-lead alloy with an admixture of copper particles of various mass concentrations. For the select-ed combination of the analyzed metal and impurities a calibration curve of the sensor was ob-tained in the concentration range from 0 to 10%.\",\"PeriodicalId\":41257,\"journal\":{\"name\":\"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History\",\"volume\":\"54 1\",\"pages\":\"\"},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17072/1994-3598-2022-1-38-43\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HISTORY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17072/1994-3598-2022-1-38-43","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HISTORY","Score":null,"Total":0}
An inductive method for monitoring impurities in non-ferromagnetic metals
The paper presents a method for electromagnetic measurements of the chemical impurities’ con-centration in samples of non-ferrous metals. The principle of measurements is described and the in-fluence of the inaccuracy in geometric dimensions of the analyzed metal volume on the measure-ment error is established. The proposed measurement method was tested on model samples of a tin-lead alloy with an admixture of copper particles of various mass concentrations. For the select-ed combination of the analyzed metal and impurities a calibration curve of the sensor was ob-tained in the concentration range from 0 to 10%.