Dominik Henzen, Daniel Schmidhalter, Gian Guyer, Anna Stenger-Weisser, Ekin Ermiş, Robert Poel, Moritz Caspar Deml, Michael Karl Fix, Peter Manser, Daniel Matthias Aebersold, Hossein Hemmatazad
{"title":"使用机器人放射治疗设备对碳钛混合植入物附近的脊柱进行术后立体定向体放射治疗的可行性。","authors":"Dominik Henzen, Daniel Schmidhalter, Gian Guyer, Anna Stenger-Weisser, Ekin Ermiş, Robert Poel, Moritz Caspar Deml, Michael Karl Fix, Peter Manser, Daniel Matthias Aebersold, Hossein Hemmatazad","doi":"10.1186/s13014-022-02058-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>To assess the feasibility of postoperative stereotactic body radiation therapy (SBRT) for patients with hybrid implants consisting of carbon fiber reinforced polyetheretherketone and titanium (CFP-T) using CyberKnife.</p><p><strong>Materials and methods: </strong>All essential steps within a radiation therapy (RT) workflow were evaluated. First, the contouring process of target volumes and organs at risk (OAR) was done for patients with CFP-T implants. Second, after RT-planning, the accuracy of the calculated dose distributions was tested in a slab phantom and an anthropomorphic phantom using film dosimetry. As a third step, the accuracy of the mandatory image guided radiation therapy (IGRT) including automatic matching was assessed using the anthropomorphic phantom. For this goal, a standard quality assurance (QA) test was modified to carry out its IGRT part in presence of CFP-T implants.</p><p><strong>Results: </strong>Using CFP-T implants, target volumes could precisely delineated. There was no need for compromising the contours to overcome artifact obstacles. Differences between measured and calculated dose values were below 11% for the slab phantom, and at least 95% of the voxels were within 5% dose difference. The comparisons for the anthropomorphic phantom showed a gamma-passing rate (5%, 1 mm) of at least 97%. Additionally the test results with and without CFP-T implants were comparable. No issues concerning the IGRT were detected. The modified machine QA test resulted in a targeting error of 0.71 mm, which corresponds to the results of the unmodified standard tests.</p><p><strong>Conclusion: </strong>Dose calculation and delivery of postoperative spine SBRT is feasible in proximity of CFP-T implants using a CyberKnife system.</p>","PeriodicalId":54099,"journal":{"name":"DEUTSCHE ZEITSCHRIFT FUR PHILOSOPHIE","volume":"35 1","pages":"94"},"PeriodicalIF":0.2000,"publicationDate":"2022-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9097088/pdf/","citationCount":"0","resultStr":"{\"title\":\"Feasibility of postoperative spine stereotactic body radiation therapy in proximity of carbon and titanium hybrid implants using a robotic radiotherapy device.\",\"authors\":\"Dominik Henzen, Daniel Schmidhalter, Gian Guyer, Anna Stenger-Weisser, Ekin Ermiş, Robert Poel, Moritz Caspar Deml, Michael Karl Fix, Peter Manser, Daniel Matthias Aebersold, Hossein Hemmatazad\",\"doi\":\"10.1186/s13014-022-02058-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and purpose: </strong>To assess the feasibility of postoperative stereotactic body radiation therapy (SBRT) for patients with hybrid implants consisting of carbon fiber reinforced polyetheretherketone and titanium (CFP-T) using CyberKnife.</p><p><strong>Materials and methods: </strong>All essential steps within a radiation therapy (RT) workflow were evaluated. First, the contouring process of target volumes and organs at risk (OAR) was done for patients with CFP-T implants. Second, after RT-planning, the accuracy of the calculated dose distributions was tested in a slab phantom and an anthropomorphic phantom using film dosimetry. As a third step, the accuracy of the mandatory image guided radiation therapy (IGRT) including automatic matching was assessed using the anthropomorphic phantom. For this goal, a standard quality assurance (QA) test was modified to carry out its IGRT part in presence of CFP-T implants.</p><p><strong>Results: </strong>Using CFP-T implants, target volumes could precisely delineated. There was no need for compromising the contours to overcome artifact obstacles. Differences between measured and calculated dose values were below 11% for the slab phantom, and at least 95% of the voxels were within 5% dose difference. The comparisons for the anthropomorphic phantom showed a gamma-passing rate (5%, 1 mm) of at least 97%. Additionally the test results with and without CFP-T implants were comparable. No issues concerning the IGRT were detected. The modified machine QA test resulted in a targeting error of 0.71 mm, which corresponds to the results of the unmodified standard tests.</p><p><strong>Conclusion: </strong>Dose calculation and delivery of postoperative spine SBRT is feasible in proximity of CFP-T implants using a CyberKnife system.</p>\",\"PeriodicalId\":54099,\"journal\":{\"name\":\"DEUTSCHE ZEITSCHRIFT FUR PHILOSOPHIE\",\"volume\":\"35 1\",\"pages\":\"94\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9097088/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DEUTSCHE ZEITSCHRIFT FUR PHILOSOPHIE\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13014-022-02058-7\",\"RegionNum\":4,\"RegionCategory\":\"哲学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"PHILOSOPHY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEUTSCHE ZEITSCHRIFT FUR PHILOSOPHIE","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13014-022-02058-7","RegionNum":4,"RegionCategory":"哲学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"PHILOSOPHY","Score":null,"Total":0}
Feasibility of postoperative spine stereotactic body radiation therapy in proximity of carbon and titanium hybrid implants using a robotic radiotherapy device.
Background and purpose: To assess the feasibility of postoperative stereotactic body radiation therapy (SBRT) for patients with hybrid implants consisting of carbon fiber reinforced polyetheretherketone and titanium (CFP-T) using CyberKnife.
Materials and methods: All essential steps within a radiation therapy (RT) workflow were evaluated. First, the contouring process of target volumes and organs at risk (OAR) was done for patients with CFP-T implants. Second, after RT-planning, the accuracy of the calculated dose distributions was tested in a slab phantom and an anthropomorphic phantom using film dosimetry. As a third step, the accuracy of the mandatory image guided radiation therapy (IGRT) including automatic matching was assessed using the anthropomorphic phantom. For this goal, a standard quality assurance (QA) test was modified to carry out its IGRT part in presence of CFP-T implants.
Results: Using CFP-T implants, target volumes could precisely delineated. There was no need for compromising the contours to overcome artifact obstacles. Differences between measured and calculated dose values were below 11% for the slab phantom, and at least 95% of the voxels were within 5% dose difference. The comparisons for the anthropomorphic phantom showed a gamma-passing rate (5%, 1 mm) of at least 97%. Additionally the test results with and without CFP-T implants were comparable. No issues concerning the IGRT were detected. The modified machine QA test resulted in a targeting error of 0.71 mm, which corresponds to the results of the unmodified standard tests.
Conclusion: Dose calculation and delivery of postoperative spine SBRT is feasible in proximity of CFP-T implants using a CyberKnife system.
期刊介绍:
Als offenes Diskussionsforum fördert die Deutsche Zeitschrift für Philosophie den schulübergreifenden Dialog und die Kommunikation zwischen den philosophischen Kulturen. Vorrangig erscheinen Arbeiten, die aktiv in die moderne internationale philosophische Diskussion eingreifen und neue Denkansätze für sie liefern. Neben Fachaufsätzen und Essays, Interviews und Symposien publiziert die Zeitschrift Funde aus philosophischen Archiven, Diskussionen sowie Buchkritiken.