SMILE与FS-LASIK治疗中低度近视的比较

Shao Yu, Limin Fan, Shengxu Liu, Bolun Zhang, Z. Wang
{"title":"SMILE与FS-LASIK治疗中低度近视的比较","authors":"Shao Yu, Limin Fan, Shengxu Liu, Bolun Zhang, Z. Wang","doi":"10.3760/CMA.J.ISSN.1674-845X.2019.09.009","DOIUrl":null,"url":null,"abstract":"Objective: \nTo compare the optical zone decentration between small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in treating myopia and astigmatism, and to analyze the correlation between the decentration distance and corneal higher-order aberrations (HOAs), angle kappa, spherical equivalent (SE), and the dominant eye. \n \n \nMethods: \nThis research was based on the retrospective analysis of 62 patients (124 eyes) who had undergone SMILE and 44 patients (88 eyes) who had undergone FS-LASIK in Guangzhou Aier Eye Hospital between January 2018 and October 2018. Based on the 3-month postoperative tangent curvature [front] map of Pentacam, the 6 mm cutting boundary was fitted with a self-made concentric circle and the distance from the center to the top of the cornea was recorded as decentration. Independent t-tests, Pearson correlation coefficient analysis, and a chi-square test were used to analyze the collected data. \n \n \nResults: \nThe decentration was 0.27±0.14 mm for SMILE and 0.25±0.13 mm for FS-LASIK, and there was no statistically significant difference between the groups. There was a correlation between decentration distance and coma (r=0.288, P=0.009) for FS-LASIK but not for SMILE. There was no correlation between decentration distance and angle kappa or SE for both groups. There was no significant difference in eccentricity between the dominant and non-dominant eye in both groups. \n \n \nConclusions: \nThe accuracy of the manual centration location of SMILE is similar to that of the automatic centration location of FS-LASIK. There is a correlation between decentration distance and coma for FS-LASIK, but not for SMILE. There is no correlation between decentration distance and angle kappa, SE, or the dominant eye. \n \n \nKey words: \nsmall incision lenticule extraction; laser in situ keratomileusis; center shift; angel kappa; aberration","PeriodicalId":10142,"journal":{"name":"Chinese Journal of Optometry & Ophthalmology","volume":"13 1","pages":"698-702"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison of Optical Zone Decentration after SMILE and FS-LASIK for Low and Moderate Myopia\",\"authors\":\"Shao Yu, Limin Fan, Shengxu Liu, Bolun Zhang, Z. Wang\",\"doi\":\"10.3760/CMA.J.ISSN.1674-845X.2019.09.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: \\nTo compare the optical zone decentration between small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in treating myopia and astigmatism, and to analyze the correlation between the decentration distance and corneal higher-order aberrations (HOAs), angle kappa, spherical equivalent (SE), and the dominant eye. \\n \\n \\nMethods: \\nThis research was based on the retrospective analysis of 62 patients (124 eyes) who had undergone SMILE and 44 patients (88 eyes) who had undergone FS-LASIK in Guangzhou Aier Eye Hospital between January 2018 and October 2018. Based on the 3-month postoperative tangent curvature [front] map of Pentacam, the 6 mm cutting boundary was fitted with a self-made concentric circle and the distance from the center to the top of the cornea was recorded as decentration. Independent t-tests, Pearson correlation coefficient analysis, and a chi-square test were used to analyze the collected data. \\n \\n \\nResults: \\nThe decentration was 0.27±0.14 mm for SMILE and 0.25±0.13 mm for FS-LASIK, and there was no statistically significant difference between the groups. There was a correlation between decentration distance and coma (r=0.288, P=0.009) for FS-LASIK but not for SMILE. There was no correlation between decentration distance and angle kappa or SE for both groups. There was no significant difference in eccentricity between the dominant and non-dominant eye in both groups. \\n \\n \\nConclusions: \\nThe accuracy of the manual centration location of SMILE is similar to that of the automatic centration location of FS-LASIK. There is a correlation between decentration distance and coma for FS-LASIK, but not for SMILE. There is no correlation between decentration distance and angle kappa, SE, or the dominant eye. \\n \\n \\nKey words: \\nsmall incision lenticule extraction; laser in situ keratomileusis; center shift; angel kappa; aberration\",\"PeriodicalId\":10142,\"journal\":{\"name\":\"Chinese Journal of Optometry & Ophthalmology\",\"volume\":\"13 1\",\"pages\":\"698-702\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Optometry & Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1674-845X.2019.09.009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Optometry & Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1674-845X.2019.09.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:比较小切口晶状体摘出术(SMILE)与飞秒激光辅助激光原位角膜磨光术(FS-LASIK)治疗近视和散光的光学区离差,并分析离差距离与角膜高阶像差(HOAs)、角kappa、球等效(SE)、优势眼的相关性。方法:回顾性分析2018年1月至2018年10月在广州爱尔眼科医院行SMILE手术的62例(124只眼)和FS-LASIK手术的44例(88只眼)。根据术后3个月Pentacam切线曲率[前]图,在6 mm切割边界处拟合自制同心圆,记录中心到角膜顶部的距离为离心。采用独立t检验、Pearson相关系数分析和卡方检验对收集到的数据进行分析。结果:SMILE组和FS-LASIK组的游离度分别为0.27±0.14 mm和0.25±0.13 mm,两组间差异无统计学意义。FS-LASIK的离心距离与昏迷之间存在相关性(r=0.288, P=0.009), SMILE无相关性。两组分散距离与角kappa、SE均无相关性。两组的优势眼和非优势眼的偏心率无显著差异。结论:SMILE的手动定位精度与FS-LASIK的自动定位精度相近。FS-LASIK的离体距离与昏迷有相关性,SMILE无相关性。分散距离与角度kappa、SE或优势眼之间没有相关性。关键词:小切口晶状体摘除;激光原位角膜磨镶术;中心转变;天使kappa;像差
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Optical Zone Decentration after SMILE and FS-LASIK for Low and Moderate Myopia
Objective: To compare the optical zone decentration between small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in treating myopia and astigmatism, and to analyze the correlation between the decentration distance and corneal higher-order aberrations (HOAs), angle kappa, spherical equivalent (SE), and the dominant eye. Methods: This research was based on the retrospective analysis of 62 patients (124 eyes) who had undergone SMILE and 44 patients (88 eyes) who had undergone FS-LASIK in Guangzhou Aier Eye Hospital between January 2018 and October 2018. Based on the 3-month postoperative tangent curvature [front] map of Pentacam, the 6 mm cutting boundary was fitted with a self-made concentric circle and the distance from the center to the top of the cornea was recorded as decentration. Independent t-tests, Pearson correlation coefficient analysis, and a chi-square test were used to analyze the collected data. Results: The decentration was 0.27±0.14 mm for SMILE and 0.25±0.13 mm for FS-LASIK, and there was no statistically significant difference between the groups. There was a correlation between decentration distance and coma (r=0.288, P=0.009) for FS-LASIK but not for SMILE. There was no correlation between decentration distance and angle kappa or SE for both groups. There was no significant difference in eccentricity between the dominant and non-dominant eye in both groups. Conclusions: The accuracy of the manual centration location of SMILE is similar to that of the automatic centration location of FS-LASIK. There is a correlation between decentration distance and coma for FS-LASIK, but not for SMILE. There is no correlation between decentration distance and angle kappa, SE, or the dominant eye. Key words: small incision lenticule extraction; laser in situ keratomileusis; center shift; angel kappa; aberration
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信