测定人血浆中缬沙坦的生物分析方法的建立与验证

S. H. Ramadhan
{"title":"测定人血浆中缬沙坦的生物分析方法的建立与验证","authors":"S. H. Ramadhan","doi":"10.32947/ajps.v21i4.795","DOIUrl":null,"url":null,"abstract":"A bioanalytical method which utilizes high performance liquid chromatography with mass spectrometry method has been developed and validated for the quantification of valsartan in human plasma. The samples were processed by precipitation with formic acid then extracted with diethyl ether. Benazepril \n  \nwas used as an internal standard. The chromatographic separation is performed through C18 column with a mobile phase consisting of deionized water, acetonitrile and formic acid, followed by mass spectrometric detection in the positive ionization mode. The proposed method was specific and had been validated in the linear range of 50.0 – 5000.0 ng/ml for valsartan. The validation results were as follows: the intra-day and inter-day precision were 3.46 to 8.33% and 5.85 to 7.05% respectively, the intra-day and inter-day accuracy were 93.53 to 107.13% and 95.26 to 104.0% respectively. The recovery for valsartan and benazepril was 81.4% and 113.7% respectively. Also, stability was studied and the results obtained for short-term stability 99.24 to 102.32%, for freeze / thaw stability 99.75 to 99.95% and for long-term stability 98.24 to 103.03%. It can be concluded that the method can be applied in pharmacokinetic bioequivalence studies.","PeriodicalId":7406,"journal":{"name":"Al Mustansiriyah Journal of Pharmaceutical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and validation of bioanalytical method for the determination of valsartan in human plasma\",\"authors\":\"S. H. Ramadhan\",\"doi\":\"10.32947/ajps.v21i4.795\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A bioanalytical method which utilizes high performance liquid chromatography with mass spectrometry method has been developed and validated for the quantification of valsartan in human plasma. The samples were processed by precipitation with formic acid then extracted with diethyl ether. Benazepril \\n  \\nwas used as an internal standard. The chromatographic separation is performed through C18 column with a mobile phase consisting of deionized water, acetonitrile and formic acid, followed by mass spectrometric detection in the positive ionization mode. The proposed method was specific and had been validated in the linear range of 50.0 – 5000.0 ng/ml for valsartan. The validation results were as follows: the intra-day and inter-day precision were 3.46 to 8.33% and 5.85 to 7.05% respectively, the intra-day and inter-day accuracy were 93.53 to 107.13% and 95.26 to 104.0% respectively. The recovery for valsartan and benazepril was 81.4% and 113.7% respectively. Also, stability was studied and the results obtained for short-term stability 99.24 to 102.32%, for freeze / thaw stability 99.75 to 99.95% and for long-term stability 98.24 to 103.03%. It can be concluded that the method can be applied in pharmacokinetic bioequivalence studies.\",\"PeriodicalId\":7406,\"journal\":{\"name\":\"Al Mustansiriyah Journal of Pharmaceutical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Al Mustansiriyah Journal of Pharmaceutical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32947/ajps.v21i4.795\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al Mustansiriyah Journal of Pharmaceutical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32947/ajps.v21i4.795","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立了一种高效液相色谱-质谱联用的生物分析方法,用于人血浆中缬沙坦的定量分析。样品经甲酸沉淀处理,乙醚萃取。以苯那普利为内标。色谱分离采用C18柱,流动相为去离子水、乙腈和甲酸,质谱检测采用正电离模式。该方法具有特异性,在50.0 ~ 5000.0 ng/ml的线性范围内有效。验证结果为:日内、日间准确度分别为3.46 ~ 8.33%和5.85 ~ 7.05%,日内、日间准确度分别为93.53 ~ 107.13%和95.26 ~ 104.0%。缬沙坦和苯那普利的回收率分别为81.4%和113.7%。稳定性测试结果表明:短期稳定性为99.24 ~ 102.32%,冻融稳定性为99.75 ~ 99.95%,长期稳定性为98.24 ~ 103.03%。结果表明,该方法可用于药代动力学生物等效性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development and validation of bioanalytical method for the determination of valsartan in human plasma
A bioanalytical method which utilizes high performance liquid chromatography with mass spectrometry method has been developed and validated for the quantification of valsartan in human plasma. The samples were processed by precipitation with formic acid then extracted with diethyl ether. Benazepril   was used as an internal standard. The chromatographic separation is performed through C18 column with a mobile phase consisting of deionized water, acetonitrile and formic acid, followed by mass spectrometric detection in the positive ionization mode. The proposed method was specific and had been validated in the linear range of 50.0 – 5000.0 ng/ml for valsartan. The validation results were as follows: the intra-day and inter-day precision were 3.46 to 8.33% and 5.85 to 7.05% respectively, the intra-day and inter-day accuracy were 93.53 to 107.13% and 95.26 to 104.0% respectively. The recovery for valsartan and benazepril was 81.4% and 113.7% respectively. Also, stability was studied and the results obtained for short-term stability 99.24 to 102.32%, for freeze / thaw stability 99.75 to 99.95% and for long-term stability 98.24 to 103.03%. It can be concluded that the method can be applied in pharmacokinetic bioequivalence studies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信