基于粒子群算法的单相正弦波电压源逆变器谐波抑制

Spencer Prathap Singh N.M, Ajitha T
{"title":"基于粒子群算法的单相正弦波电压源逆变器谐波抑制","authors":"Spencer Prathap Singh N.M, Ajitha T","doi":"10.29121/granthaalayah.v11.i8.2023.5229","DOIUrl":null,"url":null,"abstract":"This paper explains the pruning of power harmonics in a single-phase voltage source inverter using PI controller by calculating the optimized values of PI constants by Particle Swarm Optimization (PSO) Algorithm. The mapping state space model of the sine wave inverter was formulated by considering the operating sequence of full bridge sine wave inverter. The controller acts effectively thereby reducing the voltage and current THDs in an inverter. The PSO technique is implemented which estimates the optimized parameters of constant for PI controller thereby tuning the controller for reducing the total harmonics of a full bridge inverter. The MATLAB / SIMULINK tool and experimental verifications are done for harmonic reduction, and it is found that its harmonics were reduced well than IEEE standards with improved transient response.","PeriodicalId":14374,"journal":{"name":"International Journal of Research -GRANTHAALAYAH","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PSO BASED HARMOIC MITIGATION IN SINGLE PHASE SINE WAVE VOLTAGE SOURCE INVERTER\",\"authors\":\"Spencer Prathap Singh N.M, Ajitha T\",\"doi\":\"10.29121/granthaalayah.v11.i8.2023.5229\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper explains the pruning of power harmonics in a single-phase voltage source inverter using PI controller by calculating the optimized values of PI constants by Particle Swarm Optimization (PSO) Algorithm. The mapping state space model of the sine wave inverter was formulated by considering the operating sequence of full bridge sine wave inverter. The controller acts effectively thereby reducing the voltage and current THDs in an inverter. The PSO technique is implemented which estimates the optimized parameters of constant for PI controller thereby tuning the controller for reducing the total harmonics of a full bridge inverter. The MATLAB / SIMULINK tool and experimental verifications are done for harmonic reduction, and it is found that its harmonics were reduced well than IEEE standards with improved transient response.\",\"PeriodicalId\":14374,\"journal\":{\"name\":\"International Journal of Research -GRANTHAALAYAH\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Research -GRANTHAALAYAH\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29121/granthaalayah.v11.i8.2023.5229\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Research -GRANTHAALAYAH","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29121/granthaalayah.v11.i8.2023.5229","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文通过粒子群优化算法计算PI常数的最优值,阐述了采用PI控制器对单相电压源逆变器进行功率谐波剪枝的方法。考虑全桥正弦波逆变器的工作顺序,建立了正弦波逆变器的映射状态空间模型。该控制器有效地减少了逆变器中的电压和电流THDs。实现了PSO技术,该技术估计了PI控制器的优化常数参数,从而对控制器进行了调谐,以降低全桥逆变器的总谐波。利用MATLAB / SIMULINK工具进行了谐波降阶实验验证,发现其谐波降阶优于IEEE标准,且瞬态响应有所改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PSO BASED HARMOIC MITIGATION IN SINGLE PHASE SINE WAVE VOLTAGE SOURCE INVERTER
This paper explains the pruning of power harmonics in a single-phase voltage source inverter using PI controller by calculating the optimized values of PI constants by Particle Swarm Optimization (PSO) Algorithm. The mapping state space model of the sine wave inverter was formulated by considering the operating sequence of full bridge sine wave inverter. The controller acts effectively thereby reducing the voltage and current THDs in an inverter. The PSO technique is implemented which estimates the optimized parameters of constant for PI controller thereby tuning the controller for reducing the total harmonics of a full bridge inverter. The MATLAB / SIMULINK tool and experimental verifications are done for harmonic reduction, and it is found that its harmonics were reduced well than IEEE standards with improved transient response.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信