Sally E.A. El-Ashery, Eman Y.Z. Frag, Mohamed G. Moussa, G. Mohamed
{"title":"基于离子对形成的离子选择碳糊电极测定四正丁基溴化铵","authors":"Sally E.A. El-Ashery, Eman Y.Z. Frag, Mohamed G. Moussa, G. Mohamed","doi":"10.21608/sjdfs.2018.194806","DOIUrl":null,"url":null,"abstract":"In this study, ion pairs formed between tetrabutyl ammonium bromide as surfactant and ion pairing agents as phosphotungetic acid (PTA), phosphomolybdic acid (PMA) and sodium tetraphenyl borate (NaTPB) have been used as electroactive materials for preparation of modified carbon paste electrodes (CPEs) selective to tetra-n-butyl ammonium bromide (TBAB) surfactant. Type and content of the different ion pairs on the performance of CPEs were studied. It was found that the best contents were, 15 mg of TBA-TPB (electrode I), 15 mg TBA-PTA (electrode II) and 6 mg TBA-PMA (electrode III) ion pairs, which gave the best Nernstian slope values of 59.41±0.31, 59.26±0.45 and 59.95±0.35 mVdecade, respectively. These fabricated electrodes exhibited suitable response to TBAB in a concentration range from 1.0x10 to 1.0x10 mol L with lower detection limit of 1.0x10 mol L. These fabricated electrodes exhibited fast response time of about 3, 7 and 6 s under working pH range of 3-8, 5-8 and 5-9 for electrodes I, II and III, respectively. The results obtained were satisfactory with excellent percentage recovery comparable and sometimes better than those obtained by other routine methods for the assay of TBAB surfactant.","PeriodicalId":21655,"journal":{"name":"Scientific Journal for Damietta Faculty of Science","volume":"2019 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ion selective carbon paste electrodes based on ion pair formation for determination of Tetra-n-butyl ammonium bromide\",\"authors\":\"Sally E.A. El-Ashery, Eman Y.Z. Frag, Mohamed G. Moussa, G. Mohamed\",\"doi\":\"10.21608/sjdfs.2018.194806\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, ion pairs formed between tetrabutyl ammonium bromide as surfactant and ion pairing agents as phosphotungetic acid (PTA), phosphomolybdic acid (PMA) and sodium tetraphenyl borate (NaTPB) have been used as electroactive materials for preparation of modified carbon paste electrodes (CPEs) selective to tetra-n-butyl ammonium bromide (TBAB) surfactant. Type and content of the different ion pairs on the performance of CPEs were studied. It was found that the best contents were, 15 mg of TBA-TPB (electrode I), 15 mg TBA-PTA (electrode II) and 6 mg TBA-PMA (electrode III) ion pairs, which gave the best Nernstian slope values of 59.41±0.31, 59.26±0.45 and 59.95±0.35 mVdecade, respectively. These fabricated electrodes exhibited suitable response to TBAB in a concentration range from 1.0x10 to 1.0x10 mol L with lower detection limit of 1.0x10 mol L. These fabricated electrodes exhibited fast response time of about 3, 7 and 6 s under working pH range of 3-8, 5-8 and 5-9 for electrodes I, II and III, respectively. The results obtained were satisfactory with excellent percentage recovery comparable and sometimes better than those obtained by other routine methods for the assay of TBAB surfactant.\",\"PeriodicalId\":21655,\"journal\":{\"name\":\"Scientific Journal for Damietta Faculty of Science\",\"volume\":\"2019 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scientific Journal for Damietta Faculty of Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/sjdfs.2018.194806\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientific Journal for Damietta Faculty of Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/sjdfs.2018.194806","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Ion selective carbon paste electrodes based on ion pair formation for determination of Tetra-n-butyl ammonium bromide
In this study, ion pairs formed between tetrabutyl ammonium bromide as surfactant and ion pairing agents as phosphotungetic acid (PTA), phosphomolybdic acid (PMA) and sodium tetraphenyl borate (NaTPB) have been used as electroactive materials for preparation of modified carbon paste electrodes (CPEs) selective to tetra-n-butyl ammonium bromide (TBAB) surfactant. Type and content of the different ion pairs on the performance of CPEs were studied. It was found that the best contents were, 15 mg of TBA-TPB (electrode I), 15 mg TBA-PTA (electrode II) and 6 mg TBA-PMA (electrode III) ion pairs, which gave the best Nernstian slope values of 59.41±0.31, 59.26±0.45 and 59.95±0.35 mVdecade, respectively. These fabricated electrodes exhibited suitable response to TBAB in a concentration range from 1.0x10 to 1.0x10 mol L with lower detection limit of 1.0x10 mol L. These fabricated electrodes exhibited fast response time of about 3, 7 and 6 s under working pH range of 3-8, 5-8 and 5-9 for electrodes I, II and III, respectively. The results obtained were satisfactory with excellent percentage recovery comparable and sometimes better than those obtained by other routine methods for the assay of TBAB surfactant.