{"title":"大孔径光学接触MgF2缓速器在DKIST的校准和调制","authors":"D. Harrington","doi":"10.1117/1.JATIS.9.3.038003","DOIUrl":null,"url":null,"abstract":"Abstract. Modern astronomical polarimeters often require simultaneous operation of multiple instruments over broad wavelength ranges. The 4 m DKIST solar telescope will soon cover 0.38 to 4.6 μm with at least 12 independent narrow band polarimeters, all in quasi-simultaneous operation. Calibration can be efficiently performed over this entire bandpass using our elliptical retarder design, achieved with just two optically contacted MgF2 crystal retarder pairs. Calibration requires very well-characterized, uniform, defect-free retarders and polarizers. I report here on the successful development of four extremely large aperture (d = 120 mm) optically contacted MgF2 retarder pairs used to make a DKIST calibrator and a modulator for the Cryo-NIRSP instrument. All four crystal pairs have clear apertures free of defects. New procedures deliver fast axis alignment in the range of 0.1 deg to 0.2 deg post contact bonding. For the calibrator crystals, a new process was developed using deterministic fluid jet polishing driven by retardance mapping to achieve stringent retardance spatial uniformity. I show that transmitted wavefront error is not a sufficient proxy for retardance polishing. Polishing softer MgF2 retarder crystals required substantial development to simultaneously achieve flatness, roughness, and retardance uniformity. The optical contact bond ensures there are no bonding agents (oils, epoxies) with spectral absorption bands in the entire 0.3 to 6 μm bandpass without any possibility for leaks or degradation. These four crystals will be used in DKIST and Cryo-NIRSP in a 300 W solar beam and are anticipated to mitigate heating, stability, and UV irradiation issues. I use the Berreman calculus to compute retarder depolarization, with >10 % magnitudes found at the shortest wavelengths after including typical crystal optic axis cutting errors and incidence angle variation in converging beams.","PeriodicalId":54342,"journal":{"name":"Journal of Astronomical Telescopes Instruments and Systems","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Large aperture optically contacted MgF2 retarders for calibration and modulation at DKIST\",\"authors\":\"D. Harrington\",\"doi\":\"10.1117/1.JATIS.9.3.038003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract. Modern astronomical polarimeters often require simultaneous operation of multiple instruments over broad wavelength ranges. The 4 m DKIST solar telescope will soon cover 0.38 to 4.6 μm with at least 12 independent narrow band polarimeters, all in quasi-simultaneous operation. Calibration can be efficiently performed over this entire bandpass using our elliptical retarder design, achieved with just two optically contacted MgF2 crystal retarder pairs. Calibration requires very well-characterized, uniform, defect-free retarders and polarizers. I report here on the successful development of four extremely large aperture (d = 120 mm) optically contacted MgF2 retarder pairs used to make a DKIST calibrator and a modulator for the Cryo-NIRSP instrument. All four crystal pairs have clear apertures free of defects. New procedures deliver fast axis alignment in the range of 0.1 deg to 0.2 deg post contact bonding. For the calibrator crystals, a new process was developed using deterministic fluid jet polishing driven by retardance mapping to achieve stringent retardance spatial uniformity. I show that transmitted wavefront error is not a sufficient proxy for retardance polishing. Polishing softer MgF2 retarder crystals required substantial development to simultaneously achieve flatness, roughness, and retardance uniformity. The optical contact bond ensures there are no bonding agents (oils, epoxies) with spectral absorption bands in the entire 0.3 to 6 μm bandpass without any possibility for leaks or degradation. These four crystals will be used in DKIST and Cryo-NIRSP in a 300 W solar beam and are anticipated to mitigate heating, stability, and UV irradiation issues. I use the Berreman calculus to compute retarder depolarization, with >10 % magnitudes found at the shortest wavelengths after including typical crystal optic axis cutting errors and incidence angle variation in converging beams.\",\"PeriodicalId\":54342,\"journal\":{\"name\":\"Journal of Astronomical Telescopes Instruments and Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Astronomical Telescopes Instruments and Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JATIS.9.3.038003\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, AEROSPACE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Astronomical Telescopes Instruments and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1117/1.JATIS.9.3.038003","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, AEROSPACE","Score":null,"Total":0}
Large aperture optically contacted MgF2 retarders for calibration and modulation at DKIST
Abstract. Modern astronomical polarimeters often require simultaneous operation of multiple instruments over broad wavelength ranges. The 4 m DKIST solar telescope will soon cover 0.38 to 4.6 μm with at least 12 independent narrow band polarimeters, all in quasi-simultaneous operation. Calibration can be efficiently performed over this entire bandpass using our elliptical retarder design, achieved with just two optically contacted MgF2 crystal retarder pairs. Calibration requires very well-characterized, uniform, defect-free retarders and polarizers. I report here on the successful development of four extremely large aperture (d = 120 mm) optically contacted MgF2 retarder pairs used to make a DKIST calibrator and a modulator for the Cryo-NIRSP instrument. All four crystal pairs have clear apertures free of defects. New procedures deliver fast axis alignment in the range of 0.1 deg to 0.2 deg post contact bonding. For the calibrator crystals, a new process was developed using deterministic fluid jet polishing driven by retardance mapping to achieve stringent retardance spatial uniformity. I show that transmitted wavefront error is not a sufficient proxy for retardance polishing. Polishing softer MgF2 retarder crystals required substantial development to simultaneously achieve flatness, roughness, and retardance uniformity. The optical contact bond ensures there are no bonding agents (oils, epoxies) with spectral absorption bands in the entire 0.3 to 6 μm bandpass without any possibility for leaks or degradation. These four crystals will be used in DKIST and Cryo-NIRSP in a 300 W solar beam and are anticipated to mitigate heating, stability, and UV irradiation issues. I use the Berreman calculus to compute retarder depolarization, with >10 % magnitudes found at the shortest wavelengths after including typical crystal optic axis cutting errors and incidence angle variation in converging beams.
期刊介绍:
The Journal of Astronomical Telescopes, Instruments, and Systems publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.