壳聚糖/金纳米复合膜用于双酚A电化学传感

Leandro A. Almeida, Bruno V. M. Rodrigues, D. T. Balogh, R. C. Sanfelice, L. Mercante, A. F. Frade-Barros, A. Pavinatto
{"title":"壳聚糖/金纳米复合膜用于双酚A电化学传感","authors":"Leandro A. Almeida, Bruno V. M. Rodrigues, D. T. Balogh, R. C. Sanfelice, L. Mercante, A. F. Frade-Barros, A. Pavinatto","doi":"10.3390/electrochem3020016","DOIUrl":null,"url":null,"abstract":"Bisphenol A (BPA) is considered an endocrine-disrupting compound and can cause toxicological effects, even at low doses. The development of sensitive and reliable sensors that would allow the detection of such contaminant is highly pursued. Herein, we report an electrochemical sensing strategy based on a simple and low-cost nanocomposite film sensor platform for BPA detection. The platform was developed by modifying a fluorine-doped tin oxide (FTO) electrode with layer-by-layer (LbL) films of chitosan (Chi) and gold nanoparticles functionalized with a polythiophene derivative (AuNPs:PTS). The growth of the Chi/AuNPs:PTS LbL films was monitored by UV–Vis spectroscopy. Electrochemical characterization revealed that the three-bilayer film exhibited the highest electrocatalytic performance and differential-pulse voltammetry (DPV) measurements demonstrated that the modified electrode was suitable for BPA detection through a quasi-reversible and adsorption-controlled electrochemical oxidation and reduction process. The developed sensor exhibited a linear response range from 0.4 to 20 μmol L−1, with a detection limit of 0.32 μmol L−1. The sensor showed good reproducibility with relative standard deviations of 2.12% and 3.73% to intra- and inter-electrode, respectively. Furthermore, the platform demonstrated to be suitable to detect BPA in real water samples, as well as selective for BPA detection in solutions with 100-fold excess of common interfering compounds.","PeriodicalId":11612,"journal":{"name":"Electrochem","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Chitosan/Gold Nanoparticles Nanocomposite Film for Bisphenol A Electrochemical Sensing\",\"authors\":\"Leandro A. Almeida, Bruno V. M. Rodrigues, D. T. Balogh, R. C. Sanfelice, L. Mercante, A. F. Frade-Barros, A. Pavinatto\",\"doi\":\"10.3390/electrochem3020016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bisphenol A (BPA) is considered an endocrine-disrupting compound and can cause toxicological effects, even at low doses. The development of sensitive and reliable sensors that would allow the detection of such contaminant is highly pursued. Herein, we report an electrochemical sensing strategy based on a simple and low-cost nanocomposite film sensor platform for BPA detection. The platform was developed by modifying a fluorine-doped tin oxide (FTO) electrode with layer-by-layer (LbL) films of chitosan (Chi) and gold nanoparticles functionalized with a polythiophene derivative (AuNPs:PTS). The growth of the Chi/AuNPs:PTS LbL films was monitored by UV–Vis spectroscopy. Electrochemical characterization revealed that the three-bilayer film exhibited the highest electrocatalytic performance and differential-pulse voltammetry (DPV) measurements demonstrated that the modified electrode was suitable for BPA detection through a quasi-reversible and adsorption-controlled electrochemical oxidation and reduction process. The developed sensor exhibited a linear response range from 0.4 to 20 μmol L−1, with a detection limit of 0.32 μmol L−1. The sensor showed good reproducibility with relative standard deviations of 2.12% and 3.73% to intra- and inter-electrode, respectively. Furthermore, the platform demonstrated to be suitable to detect BPA in real water samples, as well as selective for BPA detection in solutions with 100-fold excess of common interfering compounds.\",\"PeriodicalId\":11612,\"journal\":{\"name\":\"Electrochem\",\"volume\":\"49 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrochem\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/electrochem3020016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrochem","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/electrochem3020016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

双酚A (BPA)被认为是一种干扰内分泌的化合物,即使是低剂量也会引起毒性作用。开发灵敏可靠的传感器以检测此类污染物是人们高度追求的目标。在此,我们报告了一种基于简单低成本纳米复合膜传感器平台的电化学传感策略,用于BPA检测。该平台是通过用壳聚糖(Chi)和金纳米粒子(AuNPs:PTS)的层接层(LbL)膜修饰氟掺杂氧化锡(FTO)电极而开发的。紫外可见光谱法监测Chi/AuNPs:PTS LbL薄膜的生长情况。电化学表征表明,三双层膜表现出最高的电催化性能,差分脉冲伏安(DPV)测量表明,改性电极通过准可逆和吸附控制的电化学氧化和还原过程适用于双酚a检测。该传感器的线性响应范围为0.4 ~ 20 μmol L−1,检出限为0.32 μmol L−1。该传感器重复性好,电极内和电极间的相对标准偏差分别为2.12%和3.73%。此外,该平台被证明适用于检测真实水样中的BPA,以及在常见干扰化合物过量100倍的溶液中选择性检测BPA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Chitosan/Gold Nanoparticles Nanocomposite Film for Bisphenol A Electrochemical Sensing
Bisphenol A (BPA) is considered an endocrine-disrupting compound and can cause toxicological effects, even at low doses. The development of sensitive and reliable sensors that would allow the detection of such contaminant is highly pursued. Herein, we report an electrochemical sensing strategy based on a simple and low-cost nanocomposite film sensor platform for BPA detection. The platform was developed by modifying a fluorine-doped tin oxide (FTO) electrode with layer-by-layer (LbL) films of chitosan (Chi) and gold nanoparticles functionalized with a polythiophene derivative (AuNPs:PTS). The growth of the Chi/AuNPs:PTS LbL films was monitored by UV–Vis spectroscopy. Electrochemical characterization revealed that the three-bilayer film exhibited the highest electrocatalytic performance and differential-pulse voltammetry (DPV) measurements demonstrated that the modified electrode was suitable for BPA detection through a quasi-reversible and adsorption-controlled electrochemical oxidation and reduction process. The developed sensor exhibited a linear response range from 0.4 to 20 μmol L−1, with a detection limit of 0.32 μmol L−1. The sensor showed good reproducibility with relative standard deviations of 2.12% and 3.73% to intra- and inter-electrode, respectively. Furthermore, the platform demonstrated to be suitable to detect BPA in real water samples, as well as selective for BPA detection in solutions with 100-fold excess of common interfering compounds.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信