Thomas E. Sarvey, Yang Zhang, Yue Zhang, Hanju Oh, M. Bakir
{"title":"交错微针翅尺寸对三维微系统冷却的热电效应","authors":"Thomas E. Sarvey, Yang Zhang, Yue Zhang, Hanju Oh, M. Bakir","doi":"10.1109/ITHERM.2014.6892283","DOIUrl":null,"url":null,"abstract":"Microfluidic cooling shows promise in cooling next generation 3D microsystems when integrated with through-silicon-vias. In this work, electrical and thermal effects of staggered micropin-fin heat sink dimensions are analyzed using deionized water. An experimental study of five different silicon micropin-fin arrays with a nominal height of 200 μm and diameters down to 30 μm was conducted at flow rates up to approximately 100mL/min and pressure drops up to approximately 200 kPa. The lowest convective thermal resistance achieved was 0.098 °C/W across a 1 cm2 die. These experimental results were then used to simulate temperature profiles of an interposer-cooled 3D stack.","PeriodicalId":12453,"journal":{"name":"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"62 1","pages":"205-212"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Thermal and electrical effects of staggered micropin-fin dimensions for cooling of 3D microsystems\",\"authors\":\"Thomas E. Sarvey, Yang Zhang, Yue Zhang, Hanju Oh, M. Bakir\",\"doi\":\"10.1109/ITHERM.2014.6892283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Microfluidic cooling shows promise in cooling next generation 3D microsystems when integrated with through-silicon-vias. In this work, electrical and thermal effects of staggered micropin-fin heat sink dimensions are analyzed using deionized water. An experimental study of five different silicon micropin-fin arrays with a nominal height of 200 μm and diameters down to 30 μm was conducted at flow rates up to approximately 100mL/min and pressure drops up to approximately 200 kPa. The lowest convective thermal resistance achieved was 0.098 °C/W across a 1 cm2 die. These experimental results were then used to simulate temperature profiles of an interposer-cooled 3D stack.\",\"PeriodicalId\":12453,\"journal\":{\"name\":\"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)\",\"volume\":\"62 1\",\"pages\":\"205-212\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITHERM.2014.6892283\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITHERM.2014.6892283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermal and electrical effects of staggered micropin-fin dimensions for cooling of 3D microsystems
Microfluidic cooling shows promise in cooling next generation 3D microsystems when integrated with through-silicon-vias. In this work, electrical and thermal effects of staggered micropin-fin heat sink dimensions are analyzed using deionized water. An experimental study of five different silicon micropin-fin arrays with a nominal height of 200 μm and diameters down to 30 μm was conducted at flow rates up to approximately 100mL/min and pressure drops up to approximately 200 kPa. The lowest convective thermal resistance achieved was 0.098 °C/W across a 1 cm2 die. These experimental results were then used to simulate temperature profiles of an interposer-cooled 3D stack.