{"title":"M-SiSSR:使用多标记同步细分表面注册的区域心内膜功能。","authors":"Davis M Vigneault, Francisco Contijoch, Christopher P Bridge, Katherine Lowe, Chelsea Jan, Elliot R McVeigh","doi":"10.1007/978-3-030-78710-3_24","DOIUrl":null,"url":null,"abstract":"<p><p>Quantification of regional cardiac function is a central goal of cardiology. Multiple methods, such as Coherent Point Drift (CPD) and Simultaneous Subdivision Surface Registration (SiSSR), have been used to register meshes to the endocardial surface. However, these methods do not distinguish between cardiac chambers during registration, and consequently the mesh may \"slip\" across the interface between two structures during contraction, resulting in inaccurate regional functional measurements. Here, we present Multilabel-SiSSR (M-SiSSR), a novel method for registering a \"labeled\" cardiac mesh (with each triangle assigned to a cardiac structure). We compare our results to the original, label-agnostic version of SiSSR and find both a visual and quantitative improvement in tracking of the mitral valve plane.</p>","PeriodicalId":73120,"journal":{"name":"Functional imaging and modeling of the heart : ... International Workshop, FIMH ..., proceedings. FIMH","volume":"12738 1","pages":"242-252"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8918026/pdf/","citationCount":"0","resultStr":"{\"title\":\"M-SiSSR: Regional Endocardial Function Using Multilabel Simultaneous Subdivision Surface Registration.\",\"authors\":\"Davis M Vigneault, Francisco Contijoch, Christopher P Bridge, Katherine Lowe, Chelsea Jan, Elliot R McVeigh\",\"doi\":\"10.1007/978-3-030-78710-3_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Quantification of regional cardiac function is a central goal of cardiology. Multiple methods, such as Coherent Point Drift (CPD) and Simultaneous Subdivision Surface Registration (SiSSR), have been used to register meshes to the endocardial surface. However, these methods do not distinguish between cardiac chambers during registration, and consequently the mesh may \\\"slip\\\" across the interface between two structures during contraction, resulting in inaccurate regional functional measurements. Here, we present Multilabel-SiSSR (M-SiSSR), a novel method for registering a \\\"labeled\\\" cardiac mesh (with each triangle assigned to a cardiac structure). We compare our results to the original, label-agnostic version of SiSSR and find both a visual and quantitative improvement in tracking of the mitral valve plane.</p>\",\"PeriodicalId\":73120,\"journal\":{\"name\":\"Functional imaging and modeling of the heart : ... International Workshop, FIMH ..., proceedings. FIMH\",\"volume\":\"12738 1\",\"pages\":\"242-252\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8918026/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Functional imaging and modeling of the heart : ... International Workshop, FIMH ..., proceedings. FIMH\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/978-3-030-78710-3_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/6/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Functional imaging and modeling of the heart : ... International Workshop, FIMH ..., proceedings. FIMH","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/978-3-030-78710-3_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/6/18 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

量化区域心脏功能是心脏病学的核心目标。相干点漂移(CPD)和同步细分表面配准(SiSSR)等多种方法已被用于将网格配准到心内膜表面。然而,这些方法在配准过程中无法区分心腔,因此网格可能会在收缩过程中 "滑过 "两个结构之间的界面,导致区域功能测量不准确。在此,我们提出了多标签-SiSSR(M-SiSSR),这是一种用于 "标签化 "心脏网格(每个三角形分配给一个心脏结构)注册的新方法。我们将我们的结果与原始的、标签无关的 SiSSR 版本进行了比较,发现在二尖瓣平面的跟踪方面,我们的结果在视觉和数量上都有所改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
M-SiSSR: Regional Endocardial Function Using Multilabel Simultaneous Subdivision Surface Registration.

Quantification of regional cardiac function is a central goal of cardiology. Multiple methods, such as Coherent Point Drift (CPD) and Simultaneous Subdivision Surface Registration (SiSSR), have been used to register meshes to the endocardial surface. However, these methods do not distinguish between cardiac chambers during registration, and consequently the mesh may "slip" across the interface between two structures during contraction, resulting in inaccurate regional functional measurements. Here, we present Multilabel-SiSSR (M-SiSSR), a novel method for registering a "labeled" cardiac mesh (with each triangle assigned to a cardiac structure). We compare our results to the original, label-agnostic version of SiSSR and find both a visual and quantitative improvement in tracking of the mitral valve plane.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信