用于中红外区域精确平场的平校正装置的研制

IF 1.7 3区 工程技术 Q2 ENGINEERING, AEROSPACE
Akira C. Naruse, T. Kamizuka, T. Miyata, S. Sako, R. Ohsawa, K. Asano, Atsushi Nishimura, I. Sakon, Kengo Tachibana, Hirokazu Iida
{"title":"用于中红外区域精确平场的平校正装置的研制","authors":"Akira C. Naruse, T. Kamizuka, T. Miyata, S. Sako, R. Ohsawa, K. Asano, Atsushi Nishimura, I. Sakon, Kengo Tachibana, Hirokazu Iida","doi":"10.1117/1.JATIS.9.3.038004","DOIUrl":null,"url":null,"abstract":"Abstract. Time-domain astronomy is important in the field of modern astronomy, and monitoring observations in the mid-infrared region with 1% photometric accuracy to study the variables and transients is becoming essential. The non-uniformity of the sensitivity caused by the optical characteristics of instruments and differences in the response curves of individual detector pixels degrade photometric accuracy. Therefore, to achieve 1% photometric accuracy, a flat-field correction for the non-uniformity with an accuracy of better than 1% is required. We developed a flat calibration unit (FCU) consisting of a silicon lens, a blackbody source, and two flat folding mirrors. We conducted proof-of-concept tests of the FCU by measuring the accuracy and stability of flat frames obtained using the FCU. The accuracies of the flat frames were 0.23% at 7.7  μm, 0.43% at 9.6  μm, 0.34% at 11.5  μm, and 0.84% at 20.9  μm, which are sufficient to achieve 1% photometric accuracy. The flat frames obtained using the FCU were stable over a period of 29 h within the accuracies of 0.13% at 7.7  μm, 0.12% at 9.6  μm, 0.22% at 11.5  μm, and 0.52% at 20.9  μm, indicating that it is sufficient to obtain flat frames once per night.","PeriodicalId":54342,"journal":{"name":"Journal of Astronomical Telescopes Instruments and Systems","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a flat calibration unit for accurate flat fielding in the mid-infrared region\",\"authors\":\"Akira C. Naruse, T. Kamizuka, T. Miyata, S. Sako, R. Ohsawa, K. Asano, Atsushi Nishimura, I. Sakon, Kengo Tachibana, Hirokazu Iida\",\"doi\":\"10.1117/1.JATIS.9.3.038004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract. Time-domain astronomy is important in the field of modern astronomy, and monitoring observations in the mid-infrared region with 1% photometric accuracy to study the variables and transients is becoming essential. The non-uniformity of the sensitivity caused by the optical characteristics of instruments and differences in the response curves of individual detector pixels degrade photometric accuracy. Therefore, to achieve 1% photometric accuracy, a flat-field correction for the non-uniformity with an accuracy of better than 1% is required. We developed a flat calibration unit (FCU) consisting of a silicon lens, a blackbody source, and two flat folding mirrors. We conducted proof-of-concept tests of the FCU by measuring the accuracy and stability of flat frames obtained using the FCU. The accuracies of the flat frames were 0.23% at 7.7  μm, 0.43% at 9.6  μm, 0.34% at 11.5  μm, and 0.84% at 20.9  μm, which are sufficient to achieve 1% photometric accuracy. The flat frames obtained using the FCU were stable over a period of 29 h within the accuracies of 0.13% at 7.7  μm, 0.12% at 9.6  μm, 0.22% at 11.5  μm, and 0.52% at 20.9  μm, indicating that it is sufficient to obtain flat frames once per night.\",\"PeriodicalId\":54342,\"journal\":{\"name\":\"Journal of Astronomical Telescopes Instruments and Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Astronomical Telescopes Instruments and Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JATIS.9.3.038004\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, AEROSPACE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Astronomical Telescopes Instruments and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1117/1.JATIS.9.3.038004","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, AEROSPACE","Score":null,"Total":0}
引用次数: 0

摘要

摘要时域天文学在现代天文学中占有重要地位,在中红外区域以1%的光度精度监测观测以研究变量和瞬变现象已成为必要。由于仪器的光学特性和单个探测器像素响应曲线的差异导致灵敏度的不均匀性降低了光度测量的精度。因此,为了达到1%的光度精度,需要对非均匀性进行精度大于1%的平场校正。我们开发了一个平面校准单元(FCU),由一个硅透镜、一个黑体源和两个平面折叠镜组成。我们通过测量使用FCU获得的平面框架的精度和稳定性,对FCU进行了概念验证测试。在7.7 μm、9.6 μm、11.5 μm和20.9 μm处,平面框架的精度分别为0.23%、0.43%、0.34%和0.84%,足以达到1%的光度精度。在7.7 μm、9.6 μm、11.5 μm和20.9 μm的精度分别为0.13%、0.12%、0.22%和0.52%的范围内,FCU获得的平面帧在29 h内保持稳定,表明每晚获得一次平面帧是足够的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a flat calibration unit for accurate flat fielding in the mid-infrared region
Abstract. Time-domain astronomy is important in the field of modern astronomy, and monitoring observations in the mid-infrared region with 1% photometric accuracy to study the variables and transients is becoming essential. The non-uniformity of the sensitivity caused by the optical characteristics of instruments and differences in the response curves of individual detector pixels degrade photometric accuracy. Therefore, to achieve 1% photometric accuracy, a flat-field correction for the non-uniformity with an accuracy of better than 1% is required. We developed a flat calibration unit (FCU) consisting of a silicon lens, a blackbody source, and two flat folding mirrors. We conducted proof-of-concept tests of the FCU by measuring the accuracy and stability of flat frames obtained using the FCU. The accuracies of the flat frames were 0.23% at 7.7  μm, 0.43% at 9.6  μm, 0.34% at 11.5  μm, and 0.84% at 20.9  μm, which are sufficient to achieve 1% photometric accuracy. The flat frames obtained using the FCU were stable over a period of 29 h within the accuracies of 0.13% at 7.7  μm, 0.12% at 9.6  μm, 0.22% at 11.5  μm, and 0.52% at 20.9  μm, indicating that it is sufficient to obtain flat frames once per night.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.40
自引率
13.00%
发文量
119
期刊介绍: The Journal of Astronomical Telescopes, Instruments, and Systems publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信