使用低污染热液分解的高精度ID-TIMS锡石U-Pb系统:LA-ICP-MS和矿床地质年代学的意义

IF 2.7 Q2 GEOCHEMISTRY & GEOPHYSICS
S. Tapster, J. W. Bright
{"title":"使用低污染热液分解的高精度ID-TIMS锡石U-Pb系统:LA-ICP-MS和矿床地质年代学的意义","authors":"S. Tapster, J. W. Bright","doi":"10.5194/GCHRON-2-425-2020","DOIUrl":null,"url":null,"abstract":"Abstract. Cassiterite (SnO2) is the most common ore phase of Sn. Typically\ncontaining 1–100 µg g−1 of uranium and relatively low concentrations of common\nPb, cassiterite has been increasingly targeted for U–Pb geochronology,\nprincipally via microbeam methods, to understand the timing and durations\nof granite-related magmatic–hydrothermal systems throughout geological time.\nHowever, due to the extreme resistance of cassiterite to most forms of acid\ndigestion, there has been no published method permitting the complete,\nclosed-system decomposition of cassiterite under conditions in which the basic\nnecessities of measurement by isotope dilution can be met, leading to a\npaucity of reference and validation materials. To address this a new low\nblank (< 1 pg Pb) method for the complete acid decomposition of\ncassiterite utilising HBr in the presence of a mixed U–Pb tracer, U and Pb\npurification, and thermal ionisation mass\nspectrometry (TIMS) analyses has been developed. Decomposition rates have\nbeen experimentally evaluated under a range of conditions. A careful balance\nof time and temperature is required due to competing effects (e.g. HBr\noxidation), yet the decomposition of 500 µm diameter fragments of\ncassiterite is readily achievable over periods comparable to zircon\ndecomposition. Its acid-resistant nature can be turned into an advantage by\nleaching common Pb-bearing phases (e.g. sulfides, silicates) without\ndisturbing the U–Pb systematics of the cassiterite lattice. The archetypal\nSn–W greisen deposit of Cligga Head, SW England, is used to define accuracy\nrelative to chemical abrasion–isotope dilution–thermal ionisation mass\nspectrometry (CA-ID-TIMS) zircon U–Pb ages and demonstrates the potential of\nthis new method for resolving high-resolution timescales (<0.1 %) of magmatic–hydrothermal systems. However, data also indicate that the\nisotopic composition of initial common Pb varies significantly, both between\ncrystals and within a single crystal. This is attributed to significant\nfluid–rock interactions and the highly F-rich acidic nature of the\nhydrothermal system. At microbeam precision levels, this issue is largely\nunresolvable and can result in significant inaccuracy in interpreted ages.\nThe ID-TIMS U–Pb method described herein can, for the first time, be used to\nproperly characterise suitable reference materials for microbeam\ncassiterite U–Pb analyses, thus improving the accuracy of the U–Pb\ncassiterite chronometer as a whole.\n","PeriodicalId":12723,"journal":{"name":"Geochronology","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2020-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"High-precision ID-TIMS cassiterite U–Pb systematics using a low-contamination hydrothermal decomposition: implications for LA-ICP-MS and ore deposit geochronology\",\"authors\":\"S. Tapster, J. W. Bright\",\"doi\":\"10.5194/GCHRON-2-425-2020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract. Cassiterite (SnO2) is the most common ore phase of Sn. Typically\\ncontaining 1–100 µg g−1 of uranium and relatively low concentrations of common\\nPb, cassiterite has been increasingly targeted for U–Pb geochronology,\\nprincipally via microbeam methods, to understand the timing and durations\\nof granite-related magmatic–hydrothermal systems throughout geological time.\\nHowever, due to the extreme resistance of cassiterite to most forms of acid\\ndigestion, there has been no published method permitting the complete,\\nclosed-system decomposition of cassiterite under conditions in which the basic\\nnecessities of measurement by isotope dilution can be met, leading to a\\npaucity of reference and validation materials. To address this a new low\\nblank (< 1 pg Pb) method for the complete acid decomposition of\\ncassiterite utilising HBr in the presence of a mixed U–Pb tracer, U and Pb\\npurification, and thermal ionisation mass\\nspectrometry (TIMS) analyses has been developed. Decomposition rates have\\nbeen experimentally evaluated under a range of conditions. A careful balance\\nof time and temperature is required due to competing effects (e.g. HBr\\noxidation), yet the decomposition of 500 µm diameter fragments of\\ncassiterite is readily achievable over periods comparable to zircon\\ndecomposition. Its acid-resistant nature can be turned into an advantage by\\nleaching common Pb-bearing phases (e.g. sulfides, silicates) without\\ndisturbing the U–Pb systematics of the cassiterite lattice. The archetypal\\nSn–W greisen deposit of Cligga Head, SW England, is used to define accuracy\\nrelative to chemical abrasion–isotope dilution–thermal ionisation mass\\nspectrometry (CA-ID-TIMS) zircon U–Pb ages and demonstrates the potential of\\nthis new method for resolving high-resolution timescales (<0.1 %) of magmatic–hydrothermal systems. However, data also indicate that the\\nisotopic composition of initial common Pb varies significantly, both between\\ncrystals and within a single crystal. This is attributed to significant\\nfluid–rock interactions and the highly F-rich acidic nature of the\\nhydrothermal system. At microbeam precision levels, this issue is largely\\nunresolvable and can result in significant inaccuracy in interpreted ages.\\nThe ID-TIMS U–Pb method described herein can, for the first time, be used to\\nproperly characterise suitable reference materials for microbeam\\ncassiterite U–Pb analyses, thus improving the accuracy of the U–Pb\\ncassiterite chronometer as a whole.\\n\",\"PeriodicalId\":12723,\"journal\":{\"name\":\"Geochronology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2020-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Geochronology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5194/GCHRON-2-425-2020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GEOCHEMISTRY & GEOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geochronology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/GCHRON-2-425-2020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 21

摘要

摘要锡石(SnO2)是锡最常见的矿相。锡石通常含有1 - 100 μ g g−1的铀和相对较低浓度的普通pb,主要是通过微束方法来了解整个地质时期与花岗岩相关的岩浆-热液系统的时间和持续时间,因此越来越多地成为U-Pb地质年代学的目标。然而,由于锡石对大多数形式的酸消化具有极大的抗性,目前还没有发表的方法可以在满足同位素稀释测量基本要求的条件下对锡石进行完全的封闭系统分解,导致缺乏参考材料和验证材料。为了解决这个问题,开发了一种新的低空白(< 1 pg Pb)方法,用于在混合U - Pb示踪剂存在下利用HBr完全酸分解锡石,U和pb纯化以及热电离质谱(TIMS)分析。分解速率已在一系列条件下进行了实验评估。由于相互竞争的影响(如hbro氧化),需要时间和温度的仔细平衡,然而,分解直径500微米的锡石碎片很容易实现,其时间与分解锆的时间相当。它的耐酸特性可以通过浸出常见的含铅相(例如硫化物,硅酸盐)而不干扰锡石晶格的U-Pb系统而转化为优势。英国西南部Cligga Head的典型sn - w格雷森矿床被用于确定相对于化学磨损-同位素稀释-热电离质谱(CA-ID-TIMS)锆石U-Pb年龄的准确性,并证明了这种新方法在解决岩浆-热液系统的高分辨率时间尺度(< 0.1%)方面的潜力。然而,数据也表明,初始普通铅的同位素组成在晶体之间和单晶内都有显著差异。这归因于显著的流体-岩石相互作用和热液系统的高富f酸性。在微束精度水平上,这个问题在很大程度上是无法解决的,并且可能导致解释年龄的显著不准确。本文所描述的ID-TIMS U-Pb方法首次可用于微束锡石U-Pb分析的合适参考物质的适当表征,从而从整体上提高了u -铅锡石计时器的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High-precision ID-TIMS cassiterite U–Pb systematics using a low-contamination hydrothermal decomposition: implications for LA-ICP-MS and ore deposit geochronology
Abstract. Cassiterite (SnO2) is the most common ore phase of Sn. Typically containing 1–100 µg g−1 of uranium and relatively low concentrations of common Pb, cassiterite has been increasingly targeted for U–Pb geochronology, principally via microbeam methods, to understand the timing and durations of granite-related magmatic–hydrothermal systems throughout geological time. However, due to the extreme resistance of cassiterite to most forms of acid digestion, there has been no published method permitting the complete, closed-system decomposition of cassiterite under conditions in which the basic necessities of measurement by isotope dilution can be met, leading to a paucity of reference and validation materials. To address this a new low blank (< 1 pg Pb) method for the complete acid decomposition of cassiterite utilising HBr in the presence of a mixed U–Pb tracer, U and Pb purification, and thermal ionisation mass spectrometry (TIMS) analyses has been developed. Decomposition rates have been experimentally evaluated under a range of conditions. A careful balance of time and temperature is required due to competing effects (e.g. HBr oxidation), yet the decomposition of 500 µm diameter fragments of cassiterite is readily achievable over periods comparable to zircon decomposition. Its acid-resistant nature can be turned into an advantage by leaching common Pb-bearing phases (e.g. sulfides, silicates) without disturbing the U–Pb systematics of the cassiterite lattice. The archetypal Sn–W greisen deposit of Cligga Head, SW England, is used to define accuracy relative to chemical abrasion–isotope dilution–thermal ionisation mass spectrometry (CA-ID-TIMS) zircon U–Pb ages and demonstrates the potential of this new method for resolving high-resolution timescales (<0.1 %) of magmatic–hydrothermal systems. However, data also indicate that the isotopic composition of initial common Pb varies significantly, both between crystals and within a single crystal. This is attributed to significant fluid–rock interactions and the highly F-rich acidic nature of the hydrothermal system. At microbeam precision levels, this issue is largely unresolvable and can result in significant inaccuracy in interpreted ages. The ID-TIMS U–Pb method described herein can, for the first time, be used to properly characterise suitable reference materials for microbeam cassiterite U–Pb analyses, thus improving the accuracy of the U–Pb cassiterite chronometer as a whole.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Geochronology
Geochronology Earth and Planetary Sciences-Paleontology
CiteScore
6.60
自引率
0.00%
发文量
35
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信