T. Machappa, K. Anilkumar, M. Sasikala, M. A. Ambika Prasad
{"title":"导电聚苯胺/陶瓷复合材料传感器装置设计及湿度传感性能研究","authors":"T. Machappa, K. Anilkumar, M. Sasikala, M. A. Ambika Prasad","doi":"10.1109/ICSENST.2008.4757114","DOIUrl":null,"url":null,"abstract":"Sensor setup for the measurement of humidity was designed using square glass chamber provided with sample holder, vaporizer, hygrometer and temperature display. Using this set up, authors have studied the response time of the sensor setup and humidity sensing properties for Polyaniline (PANI) and PANI/sodium metavanadate (NaVO3) composites. The variation in electrical resistance with change in relative humidity (RH) in the range between 20 to 95% of RH is reported and this may be due to change in surface electrical resistance. The variation in resistance and hence conductivity depends on capillary condensation of water causing ionic conductivity within the sensing materials.","PeriodicalId":6299,"journal":{"name":"2008 3rd International Conference on Sensing Technology","volume":"1 1","pages":"284-288"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of sensor setup and study of humidity sensing behaviour of conducting polyaniline / ceramic composites\",\"authors\":\"T. Machappa, K. Anilkumar, M. Sasikala, M. A. Ambika Prasad\",\"doi\":\"10.1109/ICSENST.2008.4757114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sensor setup for the measurement of humidity was designed using square glass chamber provided with sample holder, vaporizer, hygrometer and temperature display. Using this set up, authors have studied the response time of the sensor setup and humidity sensing properties for Polyaniline (PANI) and PANI/sodium metavanadate (NaVO3) composites. The variation in electrical resistance with change in relative humidity (RH) in the range between 20 to 95% of RH is reported and this may be due to change in surface electrical resistance. The variation in resistance and hence conductivity depends on capillary condensation of water causing ionic conductivity within the sensing materials.\",\"PeriodicalId\":6299,\"journal\":{\"name\":\"2008 3rd International Conference on Sensing Technology\",\"volume\":\"1 1\",\"pages\":\"284-288\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 3rd International Conference on Sensing Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2008.4757114\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 3rd International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2008.4757114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of sensor setup and study of humidity sensing behaviour of conducting polyaniline / ceramic composites
Sensor setup for the measurement of humidity was designed using square glass chamber provided with sample holder, vaporizer, hygrometer and temperature display. Using this set up, authors have studied the response time of the sensor setup and humidity sensing properties for Polyaniline (PANI) and PANI/sodium metavanadate (NaVO3) composites. The variation in electrical resistance with change in relative humidity (RH) in the range between 20 to 95% of RH is reported and this may be due to change in surface electrical resistance. The variation in resistance and hence conductivity depends on capillary condensation of water causing ionic conductivity within the sensing materials.