{"title":"用爱尔康百夫长银系统重力-FMS (ACenSS)和ACenSS玻璃体切割探针(23G)配合外部光源进行23G玻璃体切割的新技术","authors":"Kaluarachchi Ts","doi":"10.23880/oajo-16000249","DOIUrl":null,"url":null,"abstract":"Dual pneumatic 23G vitrectomy cutters of both Alcon Constellation Vision System (AConsVS) and ACenSS have cut rates of 5000 cpm. Aims: To report a novel technique of using ACenSS 23G Vitrectomy cutter for trocar surgery with an external light source in Teaching hospital Rathnapura Sri Lanka from 01/03/2022 to 30/09/2022. Methods: 23G Alcon light probes were used with Retikare (ICON Medicare Tamil Nadu India) external light source for endoillumination. Infusion pressure was set at 65cmH2O (47.81 mmHg) and infusion line connected to eye through a 3 ways tap. ACenSS-GFMS aspiration line connected to aspiration line of vitrectomy probe. Cryopexy used to seal retinal tears as no endolaser facility. Volk surgical corneal lenses with Zeiss Lumera I microscope provided the viewing. ACenSS foot pedal was programmed to 3 modes of vitrectomy with navigation, cutter on/ off function and on/pause of continuous irrigation. A gravity driven another infusion line is used to keep the infusion when endo diathermy is used. Results: When working on maximum cut rate of the ACenSS GFMS (5000 cpm) for long duration machine automatically stops and a restart with reprime needed. Therefore, cut rates were set at a lower rate to work without interruption (core vitrectomy2000 cpm, peripheral trim- 3000cpm and for epinucleus removal 4000 cpm). No retinal traction or ridging of retina was observed at peripheral trim. Total of 210 TPPVs were performed with this technique. Conclusions: 23G TPPV with ACenSS using an external light source is a simple, safe and a cost-effective technique with equal outcome to AConsVS.","PeriodicalId":91939,"journal":{"name":"Open access journal of ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel Technique of 23G Pars Planar Vitrectomy (TPPV) with Alcon Centurion Silver System Gravity -FMS (ACenSS) and ACenSS Vitrectomy Probe (23G) with an External Light Source in Teaching Hospital Rathnapura Sri Lanka\",\"authors\":\"Kaluarachchi Ts\",\"doi\":\"10.23880/oajo-16000249\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Dual pneumatic 23G vitrectomy cutters of both Alcon Constellation Vision System (AConsVS) and ACenSS have cut rates of 5000 cpm. Aims: To report a novel technique of using ACenSS 23G Vitrectomy cutter for trocar surgery with an external light source in Teaching hospital Rathnapura Sri Lanka from 01/03/2022 to 30/09/2022. Methods: 23G Alcon light probes were used with Retikare (ICON Medicare Tamil Nadu India) external light source for endoillumination. Infusion pressure was set at 65cmH2O (47.81 mmHg) and infusion line connected to eye through a 3 ways tap. ACenSS-GFMS aspiration line connected to aspiration line of vitrectomy probe. Cryopexy used to seal retinal tears as no endolaser facility. Volk surgical corneal lenses with Zeiss Lumera I microscope provided the viewing. ACenSS foot pedal was programmed to 3 modes of vitrectomy with navigation, cutter on/ off function and on/pause of continuous irrigation. A gravity driven another infusion line is used to keep the infusion when endo diathermy is used. Results: When working on maximum cut rate of the ACenSS GFMS (5000 cpm) for long duration machine automatically stops and a restart with reprime needed. Therefore, cut rates were set at a lower rate to work without interruption (core vitrectomy2000 cpm, peripheral trim- 3000cpm and for epinucleus removal 4000 cpm). No retinal traction or ridging of retina was observed at peripheral trim. Total of 210 TPPVs were performed with this technique. Conclusions: 23G TPPV with ACenSS using an external light source is a simple, safe and a cost-effective technique with equal outcome to AConsVS.\",\"PeriodicalId\":91939,\"journal\":{\"name\":\"Open access journal of ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open access journal of ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23880/oajo-16000249\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open access journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23880/oajo-16000249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

爱尔康星座视觉系统(AConsVS)和ACenSS的双气动23G玻璃体切割切割机切割速度为5000 cpm。目的:报告于2022年3月1日至2022年9月30日在斯里兰卡Rathnapura教学医院使用ACenSS 23G玻璃体切割切割机进行外部光源套管针手术的新技术。方法:采用23G Alcon光探针与Retikare (ICON Medicare Tamil Nadu India)外光源进行内照。设置输注压力为65cmH2O (47.81 mmHg),输注管通过3路水龙头连接至眼内。ACenSS-GFMS抽吸线连接玻璃体切割探头抽吸线。冷冻固定用于封闭视网膜裂孔,无激光设备。使用蔡司Lumera I显微镜观察Volk手术角膜透镜。ACenSS脚踏板编程为3种玻璃体切割模式,具有导航、切刀开/关功能和连续冲洗开/暂停功能。重力驱动的另一条输液管被用来保持输注,当使用内透热。结果:在ACenSS GFMS的最大切割速率(5000 cpm)下长时间工作时,机器自动停止,需要重新启动。因此,切割速度被设定在较低的速度,以不间断地工作(核心玻璃体切割- 2000 cpm,周围修剪- 3000cpm,核外去除4000 cpm)。外周修剪未见视网膜牵引或视网膜隆起。采用该技术共进行了210例tppv。结论:使用外部光源的23G TPPV与ACenSS是一种简单、安全、经济的技术,其效果与AConsVS相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Novel Technique of 23G Pars Planar Vitrectomy (TPPV) with Alcon Centurion Silver System Gravity -FMS (ACenSS) and ACenSS Vitrectomy Probe (23G) with an External Light Source in Teaching Hospital Rathnapura Sri Lanka
Dual pneumatic 23G vitrectomy cutters of both Alcon Constellation Vision System (AConsVS) and ACenSS have cut rates of 5000 cpm. Aims: To report a novel technique of using ACenSS 23G Vitrectomy cutter for trocar surgery with an external light source in Teaching hospital Rathnapura Sri Lanka from 01/03/2022 to 30/09/2022. Methods: 23G Alcon light probes were used with Retikare (ICON Medicare Tamil Nadu India) external light source for endoillumination. Infusion pressure was set at 65cmH2O (47.81 mmHg) and infusion line connected to eye through a 3 ways tap. ACenSS-GFMS aspiration line connected to aspiration line of vitrectomy probe. Cryopexy used to seal retinal tears as no endolaser facility. Volk surgical corneal lenses with Zeiss Lumera I microscope provided the viewing. ACenSS foot pedal was programmed to 3 modes of vitrectomy with navigation, cutter on/ off function and on/pause of continuous irrigation. A gravity driven another infusion line is used to keep the infusion when endo diathermy is used. Results: When working on maximum cut rate of the ACenSS GFMS (5000 cpm) for long duration machine automatically stops and a restart with reprime needed. Therefore, cut rates were set at a lower rate to work without interruption (core vitrectomy2000 cpm, peripheral trim- 3000cpm and for epinucleus removal 4000 cpm). No retinal traction or ridging of retina was observed at peripheral trim. Total of 210 TPPVs were performed with this technique. Conclusions: 23G TPPV with ACenSS using an external light source is a simple, safe and a cost-effective technique with equal outcome to AConsVS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信