{"title":"神经网络观测器在显著极同步发电机动态参数在线估计中的应用","authors":"O. Shariati, A. Zin, M. Aghamohammadi","doi":"10.1109/ICMSAO.2011.5775505","DOIUrl":null,"url":null,"abstract":"Parameter identification is critical for modern control strategies in electrical power systems which is considered both dynamic performance and energy efficiency. This paper presents a novel application of ANN observers in estimating and tracking Salient-Pole Synchronous Generator Dynamic Parameters using time-domain, on-line disturbance measurements. The data for training ANN Observers are obtained through off-line simulations of a salient-pole synchronous generator operating in a one-machine-infinite-bus environment. The Levenberg-Marquardt algorithm has been adopted and assimilated into the back-propagation learning algorithm for training feed-forward neural networks. The inputs of ANNs are organized in conformity with the results of the observability analysis of synchronous generator dynamic parameters in its dynamic behavior. A collection of ANNs with same inputs but different outputs are developed to determine a set of the dynamic parameters. The ANNs are employed to estimate the dynamic parameters by the measurements which are carried out within each kind of fault separately. The trained ANNs are tested with on-line measurements to identify the dynamic parameters. Simulation studies indicate the ANN observer has a great ability to identify the dynamic parameters of salient-pole synchronous generator. The results also show that the tests which have given better results in estimation of each dynamic parameter can be obtained.","PeriodicalId":6383,"journal":{"name":"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Application of neural network observer for on-line estimation of salient-pole synchronous generators' dynamic parameters using the operating data\",\"authors\":\"O. Shariati, A. Zin, M. Aghamohammadi\",\"doi\":\"10.1109/ICMSAO.2011.5775505\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Parameter identification is critical for modern control strategies in electrical power systems which is considered both dynamic performance and energy efficiency. This paper presents a novel application of ANN observers in estimating and tracking Salient-Pole Synchronous Generator Dynamic Parameters using time-domain, on-line disturbance measurements. The data for training ANN Observers are obtained through off-line simulations of a salient-pole synchronous generator operating in a one-machine-infinite-bus environment. The Levenberg-Marquardt algorithm has been adopted and assimilated into the back-propagation learning algorithm for training feed-forward neural networks. The inputs of ANNs are organized in conformity with the results of the observability analysis of synchronous generator dynamic parameters in its dynamic behavior. A collection of ANNs with same inputs but different outputs are developed to determine a set of the dynamic parameters. The ANNs are employed to estimate the dynamic parameters by the measurements which are carried out within each kind of fault separately. The trained ANNs are tested with on-line measurements to identify the dynamic parameters. Simulation studies indicate the ANN observer has a great ability to identify the dynamic parameters of salient-pole synchronous generator. The results also show that the tests which have given better results in estimation of each dynamic parameter can be obtained.\",\"PeriodicalId\":6383,\"journal\":{\"name\":\"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMSAO.2011.5775505\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMSAO.2011.5775505","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of neural network observer for on-line estimation of salient-pole synchronous generators' dynamic parameters using the operating data
Parameter identification is critical for modern control strategies in electrical power systems which is considered both dynamic performance and energy efficiency. This paper presents a novel application of ANN observers in estimating and tracking Salient-Pole Synchronous Generator Dynamic Parameters using time-domain, on-line disturbance measurements. The data for training ANN Observers are obtained through off-line simulations of a salient-pole synchronous generator operating in a one-machine-infinite-bus environment. The Levenberg-Marquardt algorithm has been adopted and assimilated into the back-propagation learning algorithm for training feed-forward neural networks. The inputs of ANNs are organized in conformity with the results of the observability analysis of synchronous generator dynamic parameters in its dynamic behavior. A collection of ANNs with same inputs but different outputs are developed to determine a set of the dynamic parameters. The ANNs are employed to estimate the dynamic parameters by the measurements which are carried out within each kind of fault separately. The trained ANNs are tested with on-line measurements to identify the dynamic parameters. Simulation studies indicate the ANN observer has a great ability to identify the dynamic parameters of salient-pole synchronous generator. The results also show that the tests which have given better results in estimation of each dynamic parameter can be obtained.