Sandip A. Telavane, S. Kothari, Manohar V. Lokhande
{"title":"富马酸比索洛尔中残留溶剂的气相色谱验证方法","authors":"Sandip A. Telavane, S. Kothari, Manohar V. Lokhande","doi":"10.52711/2231-5691.2021.00028","DOIUrl":null,"url":null,"abstract":"Validation is important technique for detection, progress and estimation of drugs for pharmaceutical analysis. Aim of this article was to check the progress and validation of the method employed for the Residual Solvents in Bisoprolol Fumarate by Gas Chromatographic technique. The objective of this protocol is to validate a GC method of analysis for detection and Quantification of Residual Solvents Methanol, Acetone and Methylene dichloride in Bisoprolol Fumarate. In the pharmaceutical industry, validation policy is more important for documented of validation, types of validation and validation policy. The method was developed accurately and validation parameters are explained. Chromatographic condition was GC- 2014, gas chromatograph equipped with FID detector, column: 30 m x 0.32 mm ID x 1.8 µm DB - 624 capillary column or equivalent and column temperature was 45°C (hold 7 minutes) to 250°C @ 40°C/minutes, hold at 250°C for 3 minutes. The parameters such as Accuracy, Specificity, Precision, Linearity and Range, Limit of detection (LOD), Limit of quantitation (LOQ), ruggedness, robustness and system suitability testing with residual solvent such as Methanol, Acetone and methylene dichloride. All validation parameters are used in the routine and stability analysis.","PeriodicalId":8537,"journal":{"name":"Asian Journal of Pharmaceutical Research","volume":"97 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Method of Validation for Residual Solvents in Bisoprolol Fumarate by GC Technique\",\"authors\":\"Sandip A. Telavane, S. Kothari, Manohar V. Lokhande\",\"doi\":\"10.52711/2231-5691.2021.00028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Validation is important technique for detection, progress and estimation of drugs for pharmaceutical analysis. Aim of this article was to check the progress and validation of the method employed for the Residual Solvents in Bisoprolol Fumarate by Gas Chromatographic technique. The objective of this protocol is to validate a GC method of analysis for detection and Quantification of Residual Solvents Methanol, Acetone and Methylene dichloride in Bisoprolol Fumarate. In the pharmaceutical industry, validation policy is more important for documented of validation, types of validation and validation policy. The method was developed accurately and validation parameters are explained. Chromatographic condition was GC- 2014, gas chromatograph equipped with FID detector, column: 30 m x 0.32 mm ID x 1.8 µm DB - 624 capillary column or equivalent and column temperature was 45°C (hold 7 minutes) to 250°C @ 40°C/minutes, hold at 250°C for 3 minutes. The parameters such as Accuracy, Specificity, Precision, Linearity and Range, Limit of detection (LOD), Limit of quantitation (LOQ), ruggedness, robustness and system suitability testing with residual solvent such as Methanol, Acetone and methylene dichloride. All validation parameters are used in the routine and stability analysis.\",\"PeriodicalId\":8537,\"journal\":{\"name\":\"Asian Journal of Pharmaceutical Research\",\"volume\":\"97 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Pharmaceutical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52711/2231-5691.2021.00028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/2231-5691.2021.00028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
验证是药物分析中药物检测、进展和评价的重要技术。本文综述了气相色谱法测定富马酸比索洛尔中残留溶剂的研究进展及方法的有效性。本实验的目的是验证气相色谱法检测和定量富马酸比索洛尔中残留溶剂甲醇、丙酮和二氯二甲基的方法。在制药行业中,验证策略对验证文件、验证类型和验证策略更为重要。该方法开发准确,并对验证参数进行了说明。色谱条件为GC- 2014,气相色谱仪配备FID检测器,柱:30 m × 0.32 mm ID × 1.8µm DB - 624毛细管柱或同等物,柱温45°C(保持7分钟)至250°C @ 40°C/分钟,在250°C保持3分钟。准确度、专度、精密度、线性和范围、检出限(LOD)、定量限(LOQ)、坚固性、稳健性和系统适用性等参数与残留溶剂(如甲醇、丙酮和二氯甲烷)进行测试。所有验证参数均用于常规分析和稳定性分析。
Method of Validation for Residual Solvents in Bisoprolol Fumarate by GC Technique
Validation is important technique for detection, progress and estimation of drugs for pharmaceutical analysis. Aim of this article was to check the progress and validation of the method employed for the Residual Solvents in Bisoprolol Fumarate by Gas Chromatographic technique. The objective of this protocol is to validate a GC method of analysis for detection and Quantification of Residual Solvents Methanol, Acetone and Methylene dichloride in Bisoprolol Fumarate. In the pharmaceutical industry, validation policy is more important for documented of validation, types of validation and validation policy. The method was developed accurately and validation parameters are explained. Chromatographic condition was GC- 2014, gas chromatograph equipped with FID detector, column: 30 m x 0.32 mm ID x 1.8 µm DB - 624 capillary column or equivalent and column temperature was 45°C (hold 7 minutes) to 250°C @ 40°C/minutes, hold at 250°C for 3 minutes. The parameters such as Accuracy, Specificity, Precision, Linearity and Range, Limit of detection (LOD), Limit of quantitation (LOQ), ruggedness, robustness and system suitability testing with residual solvent such as Methanol, Acetone and methylene dichloride. All validation parameters are used in the routine and stability analysis.