血管内超声引导下经皮冠状动脉介入治疗中造影剂的使用减少。莫扎特随机研究1年随访

José Mariani Jr., Fernando Roberto De Fazzio, Fernando Luis Melo Bernardi, Breno de Alencar Araripe Falcão, Cristiano Guedes Bezerra, Antonio Esteves Filho, Paulo Rogério Soares, Sílvio Zalc, Roberto Kalil Filho, Pedro Alves Lemos Neto
{"title":"血管内超声引导下经皮冠状动脉介入治疗中造影剂的使用减少。莫扎特随机研究1年随访","authors":"José Mariani Jr.,&nbsp;Fernando Roberto De Fazzio,&nbsp;Fernando Luis Melo Bernardi,&nbsp;Breno de Alencar Araripe Falcão,&nbsp;Cristiano Guedes Bezerra,&nbsp;Antonio Esteves Filho,&nbsp;Paulo Rogério Soares,&nbsp;Sílvio Zalc,&nbsp;Roberto Kalil Filho,&nbsp;Pedro Alves Lemos Neto","doi":"10.1016/j.rbci.2015.08.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Introdução</h3><p>Recentemente, o estudo MOZART demonstrou que a utilização do ultrassom intracoronário (USIC) para guiar a intervenção coronariana percutânea (ICP) diminui o volume de contraste utilizado no procedimento. Avaliamos a incidência de eventos adversos cardiovasculares tardios desses pacientes.</p></div><div><h3>Métodos</h3><p>Pacientes com risco para nefropatia induzida por contraste (NIC) ou para sobrecarga de volume, e com indicação de ICP, foram randomizados para procedimento guiado pela angiografia ou USIC, e acompanhados por um período de 1 ano.</p></div><div><h3>Resultados</h3><p>Incluídos 83 pacientes nos grupos ICP guiado por angiografia (n = 42) ou USIC (n = 41), sendo que 77,1% eram diabéticos e 44,6% tinham <em>clearance</em> de creatinina &lt; 60<!--> <!-->mL/min/1,73m<sup>2</sup>. As características clínicas e angiográficas não mostraram diferenças entre os grupos. A maioria tinha lesões tipo B2/C (89,8%) e uma mediana de dois stents foram usados (intervalo interquartil: 1,0‐2,0 stents). O tempo de procedimento da ICP guiada por USIC foi 14 minutos maior do que no grupo guiado por angiografia (<em>p</em> = 0,006). No entanto, os grupos não diferiram em relação ao tempo de fluoroscopia ou à média de aquisições de imagem por procedimento. A NIC ocorreu em 19,0% vs. 7,3% (<em>p</em> = 0,26). No período de seguimento de 1 ano, 12% dos pacientes apresentaram algum evento cardiovascular maior, sendo dois óbitos (um para cada grupo), e não houve diferenças entre os grupos.</p></div><div><h3>Conclusões</h3><p>A estratégia de redução de contraste com a ICP guiada pelo ultrassom intravascular, em pacientes com risco para NIC ou sobrecarga de volume, mostrou‐se segura a curto e longo prazos.</p></div><div><h3>Background</h3><p>Recently, the MOZART study demonstrated that using intravascular ultrasound (IVUS) for guiding percutaneous coronary intervention (PCI) reduces the volume of contrast used in the procedure. The authors assessed the incidence of late adverse cardiovascular events in these patients.</p></div><div><h3>Methods</h3><p>Patients at risk for contrast‐induced nephropathy (CIN) or volume overload were randomized to angiography‐guided versus IVUS‐guided PCI, and followed‐up for a 1‐year period.</p></div><div><h3>Results</h3><p>Eighty‐three patients were included in the angiography‐guided (n = 42) or IVUS‐guided (n = 41) groups, of whom 77.1% were diabetics and 44.6% had creatinine clearance &lt; 60<!--> <!-->mL/min/1.73m<sup>2</sup>. Clinical and angiographic characteristics did not differ between the groups. Most had type B2/C lesions (89.8%) and a median of two stents were used (interquartile range: 1.0‐2.0 stents). The duration of IVUS‐guided PCI was 14<!--> <!-->minutes longer than the angiography‐guided PCI group (<em>p</em> = 0.006). However, the groups did not differ regarding fluoroscopy time or mean image acquisitions per procedure. CIN occurred in 19.0% vs. 7.3% (<em>p</em> = 0.26). During the 1‐year follow‐up, 12% of patients had a major cardiovascular event, with two deaths (one in each group), and no differences were found between groups.</p></div><div><h3>Conclusions</h3><p>The contrast reduction strategy with IVUS‐guided PCI in patients at risk for CIN or volume overload was shown to be safe in the short and long term.</p></div>","PeriodicalId":101093,"journal":{"name":"Revista Brasileira de Cardiologia Invasiva","volume":"23 4","pages":"Pages 247-250"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rbci.2015.08.001","citationCount":"1","resultStr":"{\"title\":\"Utilização minimizada de contraste na intervenção coronária percutaânea guiada pelo ultrassom intravascular. Seguimento de 1 ano do estudo randomizado MOZART\",\"authors\":\"José Mariani Jr.,&nbsp;Fernando Roberto De Fazzio,&nbsp;Fernando Luis Melo Bernardi,&nbsp;Breno de Alencar Araripe Falcão,&nbsp;Cristiano Guedes Bezerra,&nbsp;Antonio Esteves Filho,&nbsp;Paulo Rogério Soares,&nbsp;Sílvio Zalc,&nbsp;Roberto Kalil Filho,&nbsp;Pedro Alves Lemos Neto\",\"doi\":\"10.1016/j.rbci.2015.08.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introdução</h3><p>Recentemente, o estudo MOZART demonstrou que a utilização do ultrassom intracoronário (USIC) para guiar a intervenção coronariana percutânea (ICP) diminui o volume de contraste utilizado no procedimento. Avaliamos a incidência de eventos adversos cardiovasculares tardios desses pacientes.</p></div><div><h3>Métodos</h3><p>Pacientes com risco para nefropatia induzida por contraste (NIC) ou para sobrecarga de volume, e com indicação de ICP, foram randomizados para procedimento guiado pela angiografia ou USIC, e acompanhados por um período de 1 ano.</p></div><div><h3>Resultados</h3><p>Incluídos 83 pacientes nos grupos ICP guiado por angiografia (n = 42) ou USIC (n = 41), sendo que 77,1% eram diabéticos e 44,6% tinham <em>clearance</em> de creatinina &lt; 60<!--> <!-->mL/min/1,73m<sup>2</sup>. As características clínicas e angiográficas não mostraram diferenças entre os grupos. A maioria tinha lesões tipo B2/C (89,8%) e uma mediana de dois stents foram usados (intervalo interquartil: 1,0‐2,0 stents). O tempo de procedimento da ICP guiada por USIC foi 14 minutos maior do que no grupo guiado por angiografia (<em>p</em> = 0,006). No entanto, os grupos não diferiram em relação ao tempo de fluoroscopia ou à média de aquisições de imagem por procedimento. A NIC ocorreu em 19,0% vs. 7,3% (<em>p</em> = 0,26). No período de seguimento de 1 ano, 12% dos pacientes apresentaram algum evento cardiovascular maior, sendo dois óbitos (um para cada grupo), e não houve diferenças entre os grupos.</p></div><div><h3>Conclusões</h3><p>A estratégia de redução de contraste com a ICP guiada pelo ultrassom intravascular, em pacientes com risco para NIC ou sobrecarga de volume, mostrou‐se segura a curto e longo prazos.</p></div><div><h3>Background</h3><p>Recently, the MOZART study demonstrated that using intravascular ultrasound (IVUS) for guiding percutaneous coronary intervention (PCI) reduces the volume of contrast used in the procedure. The authors assessed the incidence of late adverse cardiovascular events in these patients.</p></div><div><h3>Methods</h3><p>Patients at risk for contrast‐induced nephropathy (CIN) or volume overload were randomized to angiography‐guided versus IVUS‐guided PCI, and followed‐up for a 1‐year period.</p></div><div><h3>Results</h3><p>Eighty‐three patients were included in the angiography‐guided (n = 42) or IVUS‐guided (n = 41) groups, of whom 77.1% were diabetics and 44.6% had creatinine clearance &lt; 60<!--> <!-->mL/min/1.73m<sup>2</sup>. Clinical and angiographic characteristics did not differ between the groups. Most had type B2/C lesions (89.8%) and a median of two stents were used (interquartile range: 1.0‐2.0 stents). The duration of IVUS‐guided PCI was 14<!--> <!-->minutes longer than the angiography‐guided PCI group (<em>p</em> = 0.006). However, the groups did not differ regarding fluoroscopy time or mean image acquisitions per procedure. CIN occurred in 19.0% vs. 7.3% (<em>p</em> = 0.26). During the 1‐year follow‐up, 12% of patients had a major cardiovascular event, with two deaths (one in each group), and no differences were found between groups.</p></div><div><h3>Conclusions</h3><p>The contrast reduction strategy with IVUS‐guided PCI in patients at risk for CIN or volume overload was shown to be safe in the short and long term.</p></div>\",\"PeriodicalId\":101093,\"journal\":{\"name\":\"Revista Brasileira de Cardiologia Invasiva\",\"volume\":\"23 4\",\"pages\":\"Pages 247-250\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.rbci.2015.08.001\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira de Cardiologia Invasiva\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0104184317300103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Cardiologia Invasiva","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0104184317300103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

莫扎特最近的研究表明,使用冠状动脉内超声(USIC)指导经皮冠状动脉介入治疗(pci)减少了手术中使用的造影剂量。我们评估了这些患者晚期心血管不良事件的发生率。方法:有造影剂诱导肾病(cin)或容量超载风险且有ICP指征的患者被随机分配到血管造影或USIC引导的手术中,并随访1年。结果83例患者被纳入血管造影引导的ICP组(n = 42)或USIC组(n = 41),其中77.1%为糖尿病患者,44.6%为肌酐清清率< 0.01。60毫升/分钟/ 73平方米。临床和血管造影特征无差异。大多数患者为B2/C型病变(89.8%),中位使用两种支架(四分位间范围:1.0 - 2.0支架)。USIC引导的ICP手术时间比血管造影引导的组长14分钟(p = 0.006)。然而,两组在透视时间或每次程序的平均图像采集方面没有差异。cin发生率为19.0% vs. 7.3% (p = 0.26)。在1年的随访中,12%的患者出现重大心血管事件,2人死亡(每组1人),组间无差异。结论血管内超声引导ICP降低造影剂对cin或体积超载风险患者的治疗策略在短期和长期都是安全的。在此背景下,莫扎特的研究表明,使用血管内超声(IVUS)引导经皮冠状动脉介入(PCI)可以减少手术中使用的对比剂的体积。作者评估了这些患者晚期心血管不良事件的发生率。对比诱发肾病(CIN)或体积超载的风险方法被随机分配到血管造影引导与IVUS引导PCI,并随访1年。结果83例患者被纳入血管造影引导组(n = 42)或静脉造影引导组(n = 41),其中77.1%为糖尿病,44.6%肌酐清除率< <60毫升/分钟/ 1 .73m2。临床和血管造影特征在两组之间没有区别。大多数患者有B2/C型病变(89.8%),使用了两种支架的中位数(四分位数范围:1.0 - 2.0支架)。IVUS - guided PCI持续时间比血管造影- guided PCI组长14分钟(p = 0.006)。然而,花旗没有关于fluoroscopy不同时间这么形象被收购程序。CIN发生率为19.0% vs. 7.3% (p = 0.26)。在1年随访中,12%的患者发生重大心血管事件,2人死亡(每组1人),组间无差异。结论:在有CIN或体积超载风险的患者中,与IVUS - guided PCI相比,降低策略在短期和长期都是安全的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Utilização minimizada de contraste na intervenção coronária percutaânea guiada pelo ultrassom intravascular. Seguimento de 1 ano do estudo randomizado MOZART

Introdução

Recentemente, o estudo MOZART demonstrou que a utilização do ultrassom intracoronário (USIC) para guiar a intervenção coronariana percutânea (ICP) diminui o volume de contraste utilizado no procedimento. Avaliamos a incidência de eventos adversos cardiovasculares tardios desses pacientes.

Métodos

Pacientes com risco para nefropatia induzida por contraste (NIC) ou para sobrecarga de volume, e com indicação de ICP, foram randomizados para procedimento guiado pela angiografia ou USIC, e acompanhados por um período de 1 ano.

Resultados

Incluídos 83 pacientes nos grupos ICP guiado por angiografia (n = 42) ou USIC (n = 41), sendo que 77,1% eram diabéticos e 44,6% tinham clearance de creatinina < 60 mL/min/1,73m2. As características clínicas e angiográficas não mostraram diferenças entre os grupos. A maioria tinha lesões tipo B2/C (89,8%) e uma mediana de dois stents foram usados (intervalo interquartil: 1,0‐2,0 stents). O tempo de procedimento da ICP guiada por USIC foi 14 minutos maior do que no grupo guiado por angiografia (p = 0,006). No entanto, os grupos não diferiram em relação ao tempo de fluoroscopia ou à média de aquisições de imagem por procedimento. A NIC ocorreu em 19,0% vs. 7,3% (p = 0,26). No período de seguimento de 1 ano, 12% dos pacientes apresentaram algum evento cardiovascular maior, sendo dois óbitos (um para cada grupo), e não houve diferenças entre os grupos.

Conclusões

A estratégia de redução de contraste com a ICP guiada pelo ultrassom intravascular, em pacientes com risco para NIC ou sobrecarga de volume, mostrou‐se segura a curto e longo prazos.

Background

Recently, the MOZART study demonstrated that using intravascular ultrasound (IVUS) for guiding percutaneous coronary intervention (PCI) reduces the volume of contrast used in the procedure. The authors assessed the incidence of late adverse cardiovascular events in these patients.

Methods

Patients at risk for contrast‐induced nephropathy (CIN) or volume overload were randomized to angiography‐guided versus IVUS‐guided PCI, and followed‐up for a 1‐year period.

Results

Eighty‐three patients were included in the angiography‐guided (n = 42) or IVUS‐guided (n = 41) groups, of whom 77.1% were diabetics and 44.6% had creatinine clearance < 60 mL/min/1.73m2. Clinical and angiographic characteristics did not differ between the groups. Most had type B2/C lesions (89.8%) and a median of two stents were used (interquartile range: 1.0‐2.0 stents). The duration of IVUS‐guided PCI was 14 minutes longer than the angiography‐guided PCI group (p = 0.006). However, the groups did not differ regarding fluoroscopy time or mean image acquisitions per procedure. CIN occurred in 19.0% vs. 7.3% (p = 0.26). During the 1‐year follow‐up, 12% of patients had a major cardiovascular event, with two deaths (one in each group), and no differences were found between groups.

Conclusions

The contrast reduction strategy with IVUS‐guided PCI in patients at risk for CIN or volume overload was shown to be safe in the short and long term.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信