M. Matsumoto, N. Maruyama, Hiroo Watanabe, Takashi Kikuchihara, Y. Kido, A. Tsuji
{"title":"用酶联免疫吸附法分析牛、马组织和牛奶中盐酸克仑特罗的残留。","authors":"M. Matsumoto, N. Maruyama, Hiroo Watanabe, Takashi Kikuchihara, Y. Kido, A. Tsuji","doi":"10.3358/SHOKUEISHI.41.48","DOIUrl":null,"url":null,"abstract":"Residue analysis of clenbuterol (CBL) in bovine and horse tissues and cow's milk using enzyme-linked immunosorbent assay (ELISA) with alkaline phosphatase as the label is described. The detection limit of the ELISA established here was 0.1ng/g (0.1ppb). Tissue samples were homogenized with 3% metaphosphoric acid and cleaned up by liquid-liquid extraction with ethyl acetate. After evaporation of the ethyl acetate extract, CBL in the residue was measured by ELISA. Recoveries of CBL were 75-96% for bovine tissues, 74-98% for horse tissues and 99% for cow's milk. CBL was not detectable in bovine tissues after the 6th day of withdrawal (usual dose: 0.3mg/head, double dose: 0.6mg/head), or in horse tissues after the 25th day of withdrawal (1.6μg/kg, twice a day, for 11 days). CBL concentration in horse plasma fell below the detection limit within 24 hours after the final administration. CBL was not detectable after 2.5 days of withdrawal in cow's milk or after 6 hours (usual dose group) or 24 hours (double dose group) in cow's plasma.","PeriodicalId":17269,"journal":{"name":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","volume":"570 1","pages":"48-53"},"PeriodicalIF":0.0000,"publicationDate":"2000-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Residue analysis of clenbuterol in bovine and horse tissues and cow's milk by enzyme-linked immunosorbent assay.\",\"authors\":\"M. Matsumoto, N. Maruyama, Hiroo Watanabe, Takashi Kikuchihara, Y. Kido, A. Tsuji\",\"doi\":\"10.3358/SHOKUEISHI.41.48\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Residue analysis of clenbuterol (CBL) in bovine and horse tissues and cow's milk using enzyme-linked immunosorbent assay (ELISA) with alkaline phosphatase as the label is described. The detection limit of the ELISA established here was 0.1ng/g (0.1ppb). Tissue samples were homogenized with 3% metaphosphoric acid and cleaned up by liquid-liquid extraction with ethyl acetate. After evaporation of the ethyl acetate extract, CBL in the residue was measured by ELISA. Recoveries of CBL were 75-96% for bovine tissues, 74-98% for horse tissues and 99% for cow's milk. CBL was not detectable in bovine tissues after the 6th day of withdrawal (usual dose: 0.3mg/head, double dose: 0.6mg/head), or in horse tissues after the 25th day of withdrawal (1.6μg/kg, twice a day, for 11 days). CBL concentration in horse plasma fell below the detection limit within 24 hours after the final administration. CBL was not detectable after 2.5 days of withdrawal in cow's milk or after 6 hours (usual dose group) or 24 hours (double dose group) in cow's plasma.\",\"PeriodicalId\":17269,\"journal\":{\"name\":\"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)\",\"volume\":\"570 1\",\"pages\":\"48-53\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3358/SHOKUEISHI.41.48\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3358/SHOKUEISHI.41.48","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Residue analysis of clenbuterol in bovine and horse tissues and cow's milk by enzyme-linked immunosorbent assay.
Residue analysis of clenbuterol (CBL) in bovine and horse tissues and cow's milk using enzyme-linked immunosorbent assay (ELISA) with alkaline phosphatase as the label is described. The detection limit of the ELISA established here was 0.1ng/g (0.1ppb). Tissue samples were homogenized with 3% metaphosphoric acid and cleaned up by liquid-liquid extraction with ethyl acetate. After evaporation of the ethyl acetate extract, CBL in the residue was measured by ELISA. Recoveries of CBL were 75-96% for bovine tissues, 74-98% for horse tissues and 99% for cow's milk. CBL was not detectable in bovine tissues after the 6th day of withdrawal (usual dose: 0.3mg/head, double dose: 0.6mg/head), or in horse tissues after the 25th day of withdrawal (1.6μg/kg, twice a day, for 11 days). CBL concentration in horse plasma fell below the detection limit within 24 hours after the final administration. CBL was not detectable after 2.5 days of withdrawal in cow's milk or after 6 hours (usual dose group) or 24 hours (double dose group) in cow's plasma.