用于可消化胶囊内窥镜系统的超宽带共形环路天线

Miah Md. Suzan, K. Haneda, C. Icheln, A. Khatun, K. Takizawa
{"title":"用于可消化胶囊内窥镜系统的超宽带共形环路天线","authors":"Miah Md. Suzan, K. Haneda, C. Icheln, A. Khatun, K. Takizawa","doi":"10.1109/EUCAP.2016.7481526","DOIUrl":null,"url":null,"abstract":"In this paper, an ultra wideband loop antenna is presented for capsule endoscope system operating around 433 MHz. The antenna occupies the outer-wall of the capsule and leaves the inner space for the other components of the capsule endoscope module. The proposed capsule antenna has a -10 dB impedance matching bandwidth of 744 MHz (from 336 to 1080 MHz). The ultra wideband characteristic enables the capsule antenna to compensate for detuning effects due to electronics components in the capsule endoscope module, different tissues in the gastrointestinal tract, and implant locations. The antenna has a nearly omnidirectional radiation pattern, which is usually required for such applications. The resonance performance of the fabricated antenna is validated by comparing the measured results with that of simulations when the antenna is placed in a human equivalent liquid phantom.","PeriodicalId":6509,"journal":{"name":"2016 10th European Conference on Antennas and Propagation (EuCAP)","volume":"21 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"An ultrawideband conformal loop antenna for ingestible capsule endoscope system\",\"authors\":\"Miah Md. Suzan, K. Haneda, C. Icheln, A. Khatun, K. Takizawa\",\"doi\":\"10.1109/EUCAP.2016.7481526\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an ultra wideband loop antenna is presented for capsule endoscope system operating around 433 MHz. The antenna occupies the outer-wall of the capsule and leaves the inner space for the other components of the capsule endoscope module. The proposed capsule antenna has a -10 dB impedance matching bandwidth of 744 MHz (from 336 to 1080 MHz). The ultra wideband characteristic enables the capsule antenna to compensate for detuning effects due to electronics components in the capsule endoscope module, different tissues in the gastrointestinal tract, and implant locations. The antenna has a nearly omnidirectional radiation pattern, which is usually required for such applications. The resonance performance of the fabricated antenna is validated by comparing the measured results with that of simulations when the antenna is placed in a human equivalent liquid phantom.\",\"PeriodicalId\":6509,\"journal\":{\"name\":\"2016 10th European Conference on Antennas and Propagation (EuCAP)\",\"volume\":\"21 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 10th European Conference on Antennas and Propagation (EuCAP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUCAP.2016.7481526\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 10th European Conference on Antennas and Propagation (EuCAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUCAP.2016.7481526","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

摘要

本文提出了一种用于胶囊内窥镜系统的超宽带环形天线,工作频率在433mhz左右。天线占据胶囊的外壁,为胶囊内窥镜模块的其他部件留出内部空间。所提出的胶囊天线具有744 MHz(从336到1080 MHz)的-10 dB阻抗匹配带宽。超宽带特性使胶囊天线能够补偿由于胶囊内窥镜模块中的电子元件、胃肠道中的不同组织和植入物位置造成的失谐效应。天线具有几乎全向的辐射方向图,这通常是此类应用所需要的。将天线置于人体等效液体模体中,通过实测结果与仿真结果的对比,验证了天线的谐振性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An ultrawideband conformal loop antenna for ingestible capsule endoscope system
In this paper, an ultra wideband loop antenna is presented for capsule endoscope system operating around 433 MHz. The antenna occupies the outer-wall of the capsule and leaves the inner space for the other components of the capsule endoscope module. The proposed capsule antenna has a -10 dB impedance matching bandwidth of 744 MHz (from 336 to 1080 MHz). The ultra wideband characteristic enables the capsule antenna to compensate for detuning effects due to electronics components in the capsule endoscope module, different tissues in the gastrointestinal tract, and implant locations. The antenna has a nearly omnidirectional radiation pattern, which is usually required for such applications. The resonance performance of the fabricated antenna is validated by comparing the measured results with that of simulations when the antenna is placed in a human equivalent liquid phantom.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信