{"title":"基于单片机的x射线波形独立kvp计的设计","authors":"Y. Ülgen, Murat Tumer","doi":"10.5923/J.AJBE.20110101.07","DOIUrl":null,"url":null,"abstract":"The kVp setting is one of the major factors affecting the image quality in X-ray imaging and should be an- nually measured and calibrated if necessary. In this work, a kVp-meter is designed around the ATmega16 (Atmel) micro- controller, based on the physical principle that the linear attenuation coefficient of materials, namely copper has a smooth dependence on the energy level of the X- ray photons. Based on the logarithm of the ratio of the radiation intensities through 0.5mm and 1mm thick copper filters, a look-up table is generated in the range 60-120kVp. Logarithmic operation increased the precision at higher kVp values. Since sampling is performed over the exposure period in a continuous manner, the measurement is not affected by the X-ray waveform. A prototype unit was built and the performance was tested in terms of accuracy, precision and reliability.","PeriodicalId":7620,"journal":{"name":"American Journal of Biomedical Engineering","volume":"82 1","pages":"41-43"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Design of a Microcontroller Based and X-Ray Waveform Independent kVp-Meter\",\"authors\":\"Y. Ülgen, Murat Tumer\",\"doi\":\"10.5923/J.AJBE.20110101.07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The kVp setting is one of the major factors affecting the image quality in X-ray imaging and should be an- nually measured and calibrated if necessary. In this work, a kVp-meter is designed around the ATmega16 (Atmel) micro- controller, based on the physical principle that the linear attenuation coefficient of materials, namely copper has a smooth dependence on the energy level of the X- ray photons. Based on the logarithm of the ratio of the radiation intensities through 0.5mm and 1mm thick copper filters, a look-up table is generated in the range 60-120kVp. Logarithmic operation increased the precision at higher kVp values. Since sampling is performed over the exposure period in a continuous manner, the measurement is not affected by the X-ray waveform. A prototype unit was built and the performance was tested in terms of accuracy, precision and reliability.\",\"PeriodicalId\":7620,\"journal\":{\"name\":\"American Journal of Biomedical Engineering\",\"volume\":\"82 1\",\"pages\":\"41-43\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5923/J.AJBE.20110101.07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/J.AJBE.20110101.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of a Microcontroller Based and X-Ray Waveform Independent kVp-Meter
The kVp setting is one of the major factors affecting the image quality in X-ray imaging and should be an- nually measured and calibrated if necessary. In this work, a kVp-meter is designed around the ATmega16 (Atmel) micro- controller, based on the physical principle that the linear attenuation coefficient of materials, namely copper has a smooth dependence on the energy level of the X- ray photons. Based on the logarithm of the ratio of the radiation intensities through 0.5mm and 1mm thick copper filters, a look-up table is generated in the range 60-120kVp. Logarithmic operation increased the precision at higher kVp values. Since sampling is performed over the exposure period in a continuous manner, the measurement is not affected by the X-ray waveform. A prototype unit was built and the performance was tested in terms of accuracy, precision and reliability.