Huafeng Xiao, Zhijian Fang, David Xu, Bin Wu, B. Venkatesh, B. Singh
{"title":"多变流器并网配电网测试平台","authors":"Huafeng Xiao, Zhijian Fang, David Xu, Bin Wu, B. Venkatesh, B. Singh","doi":"10.1109/IPEMC.2016.7512875","DOIUrl":null,"url":null,"abstract":"Distributed renewable energy generation units with medium-voltage distribution grid integration are considered as the most effective utilization manner because of low cost. However, the medium-voltage level (typically reach to 50 kV) brings safety risks in the experimental debugging process of new circuit topologies and algorithms for medium-voltage interface converters if directly in a full-scale power environment at the beginning. The scale-down testing platform has brought many merits for the analysis and test of medium-voltage distribution grid with multiple grid-connected converters. Unfortunately, due to the lack of proper base value selection method for DC side parameters of DC/AC type converter, such a scale-down model is still unavailable till now. The theoretical reason is that presented quasi-per-unit models for DC/AC type converters resulted in the missing of physical meaning for DC side variables. In order to solve the problem, this paper proposes a novel DC side base value selection method based on the rules that the voltage relationship of DC/AC converter's two sides complies with the AC `transformer' principle, and their current relationship satisfies the `power conservation' principle, and the detail calculation procedure of the scale-down model parameters is listed. These contributions provide the bedrock for performing the analysis and test of new circuit topologies and algorithms for the medium-voltage interface converters.","PeriodicalId":6857,"journal":{"name":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","volume":"1 1","pages":"3621-3626"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A testing platform for distribution grid with multiple grid-connected converters\",\"authors\":\"Huafeng Xiao, Zhijian Fang, David Xu, Bin Wu, B. Venkatesh, B. Singh\",\"doi\":\"10.1109/IPEMC.2016.7512875\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distributed renewable energy generation units with medium-voltage distribution grid integration are considered as the most effective utilization manner because of low cost. However, the medium-voltage level (typically reach to 50 kV) brings safety risks in the experimental debugging process of new circuit topologies and algorithms for medium-voltage interface converters if directly in a full-scale power environment at the beginning. The scale-down testing platform has brought many merits for the analysis and test of medium-voltage distribution grid with multiple grid-connected converters. Unfortunately, due to the lack of proper base value selection method for DC side parameters of DC/AC type converter, such a scale-down model is still unavailable till now. The theoretical reason is that presented quasi-per-unit models for DC/AC type converters resulted in the missing of physical meaning for DC side variables. In order to solve the problem, this paper proposes a novel DC side base value selection method based on the rules that the voltage relationship of DC/AC converter's two sides complies with the AC `transformer' principle, and their current relationship satisfies the `power conservation' principle, and the detail calculation procedure of the scale-down model parameters is listed. These contributions provide the bedrock for performing the analysis and test of new circuit topologies and algorithms for the medium-voltage interface converters.\",\"PeriodicalId\":6857,\"journal\":{\"name\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"volume\":\"1 1\",\"pages\":\"3621-3626\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2016.7512875\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2016.7512875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A testing platform for distribution grid with multiple grid-connected converters
Distributed renewable energy generation units with medium-voltage distribution grid integration are considered as the most effective utilization manner because of low cost. However, the medium-voltage level (typically reach to 50 kV) brings safety risks in the experimental debugging process of new circuit topologies and algorithms for medium-voltage interface converters if directly in a full-scale power environment at the beginning. The scale-down testing platform has brought many merits for the analysis and test of medium-voltage distribution grid with multiple grid-connected converters. Unfortunately, due to the lack of proper base value selection method for DC side parameters of DC/AC type converter, such a scale-down model is still unavailable till now. The theoretical reason is that presented quasi-per-unit models for DC/AC type converters resulted in the missing of physical meaning for DC side variables. In order to solve the problem, this paper proposes a novel DC side base value selection method based on the rules that the voltage relationship of DC/AC converter's two sides complies with the AC `transformer' principle, and their current relationship satisfies the `power conservation' principle, and the detail calculation procedure of the scale-down model parameters is listed. These contributions provide the bedrock for performing the analysis and test of new circuit topologies and algorithms for the medium-voltage interface converters.