测量分娩时手施加的力

C. R. Patel, S. Poggi, C. Spong, R. Allen
{"title":"测量分娩时手施加的力","authors":"C. R. Patel, S. Poggi, C. Spong, R. Allen","doi":"10.1109/IEMBS.2002.1053031","DOIUrl":null,"url":null,"abstract":"We report on a tactile force-sensing glove worn by an obstetrician to measure the force applied on a fetal head during childbirth. The glove consists of five piezoresistive sensors strategically placed to measure normal forces applied to the head. The normal forces are converted to traction forces via laboratory calibrations. The sensors interface with a computer for real-time data acquisition and processing. The glove is being used to quantify and investigate clinician-applied forces during vaginal deliveries, with special focus on an obstetric emergency known as shoulder dystocia. A prototype version has been developed and tested with multiple birthing simulations, as well as six normal deliveries and one delivery with a compound presentation. We conclude that a tactile sensing glove can be used to study hand-applied forces during childbirth to better understand the relationship between different birthing procedures and the forces applied during them.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":"15 1","pages":"1799-1800 vol.3"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Measuring hand-applied forces during childbirth\",\"authors\":\"C. R. Patel, S. Poggi, C. Spong, R. Allen\",\"doi\":\"10.1109/IEMBS.2002.1053031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report on a tactile force-sensing glove worn by an obstetrician to measure the force applied on a fetal head during childbirth. The glove consists of five piezoresistive sensors strategically placed to measure normal forces applied to the head. The normal forces are converted to traction forces via laboratory calibrations. The sensors interface with a computer for real-time data acquisition and processing. The glove is being used to quantify and investigate clinician-applied forces during vaginal deliveries, with special focus on an obstetric emergency known as shoulder dystocia. A prototype version has been developed and tested with multiple birthing simulations, as well as six normal deliveries and one delivery with a compound presentation. We conclude that a tactile sensing glove can be used to study hand-applied forces during childbirth to better understand the relationship between different birthing procedures and the forces applied during them.\",\"PeriodicalId\":60385,\"journal\":{\"name\":\"中国地球物理学会年刊\",\"volume\":\"15 1\",\"pages\":\"1799-1800 vol.3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国地球物理学会年刊\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.2002.1053031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1053031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

我们报告了一种触觉力感应手套,由产科医生佩戴,以测量分娩时胎儿头部施加的力。该手套由五个压阻式传感器组成,用于测量施加在头部的法向力。法向力通过实验室校准转换为牵引力。传感器与计算机接口进行实时数据采集和处理。这种手套被用来量化和调查临床医生在阴道分娩时施加的力,特别关注被称为肩部难产的产科紧急情况。已经开发了一个原型版本,并进行了多次分娩模拟测试,以及六次正常分娩和一次复合分娩。我们的结论是,触觉感应手套可以用来研究分娩过程中手部施加的力,以更好地了解不同分娩过程中施加的力之间的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measuring hand-applied forces during childbirth
We report on a tactile force-sensing glove worn by an obstetrician to measure the force applied on a fetal head during childbirth. The glove consists of five piezoresistive sensors strategically placed to measure normal forces applied to the head. The normal forces are converted to traction forces via laboratory calibrations. The sensors interface with a computer for real-time data acquisition and processing. The glove is being used to quantify and investigate clinician-applied forces during vaginal deliveries, with special focus on an obstetric emergency known as shoulder dystocia. A prototype version has been developed and tested with multiple birthing simulations, as well as six normal deliveries and one delivery with a compound presentation. We conclude that a tactile sensing glove can be used to study hand-applied forces during childbirth to better understand the relationship between different birthing procedures and the forces applied during them.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
368
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信