对比剂检测的相移方差成像

M. Siepmann, M. Mienkina, G. Schmitz, S. Fokong, Zhe Liu, F. Kiessling, J. Gatjens
{"title":"对比剂检测的相移方差成像","authors":"M. Siepmann, M. Mienkina, G. Schmitz, S. Fokong, Zhe Liu, F. Kiessling, J. Gatjens","doi":"10.1109/ULTSYM.2010.5935663","DOIUrl":null,"url":null,"abstract":"A novel ultrasound contrast agent detection method that selectively detects microbubble (MB) destruction is presented. The detection is based on the variance of the phase shift of consecutive echoes. The variance for stationary echoes or motion at constant speed is determined by the noise of the acquisition system and is theoretically predicted. We hypothesize that the phase shift variance of ultrasound echoes increases during MB destruction. It is expected that this PSV is higher than the PSV for stationary echoes or motion thus allowing the detection of the agent. The hypothesis is experimentally verified in a motion phantom. In a second experiment, MB in very low concentrations are imaged to demonstrate the sensitivity of the method. The results show good agreement with theory and exhibit a clear increase in PSV for MB vs. tissue (44.8 dB). Thus, the phase shift variance can be utilized for ultrasound contrast agent detection. Microbubbles in a concentration of 100 bubbles per ml are sufficient to cause detectable signals with a contrast to tissue ratio of up to 34.7 dB. The acquisition is implemented on a free programmable clinical device. No additions or hardware modifications are necessary making the method easily translatable to most clinical systems.","PeriodicalId":6437,"journal":{"name":"2010 IEEE International Ultrasonics Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Phase shift variance imaging for contrast agent detection\",\"authors\":\"M. Siepmann, M. Mienkina, G. Schmitz, S. Fokong, Zhe Liu, F. Kiessling, J. Gatjens\",\"doi\":\"10.1109/ULTSYM.2010.5935663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel ultrasound contrast agent detection method that selectively detects microbubble (MB) destruction is presented. The detection is based on the variance of the phase shift of consecutive echoes. The variance for stationary echoes or motion at constant speed is determined by the noise of the acquisition system and is theoretically predicted. We hypothesize that the phase shift variance of ultrasound echoes increases during MB destruction. It is expected that this PSV is higher than the PSV for stationary echoes or motion thus allowing the detection of the agent. The hypothesis is experimentally verified in a motion phantom. In a second experiment, MB in very low concentrations are imaged to demonstrate the sensitivity of the method. The results show good agreement with theory and exhibit a clear increase in PSV for MB vs. tissue (44.8 dB). Thus, the phase shift variance can be utilized for ultrasound contrast agent detection. Microbubbles in a concentration of 100 bubbles per ml are sufficient to cause detectable signals with a contrast to tissue ratio of up to 34.7 dB. The acquisition is implemented on a free programmable clinical device. No additions or hardware modifications are necessary making the method easily translatable to most clinical systems.\",\"PeriodicalId\":6437,\"journal\":{\"name\":\"2010 IEEE International Ultrasonics Symposium\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE International Ultrasonics Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2010.5935663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2010.5935663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

提出了一种选择性检测微泡破坏的超声造影剂检测方法。基于连续回波相移的方差进行检测。静止回波或匀速运动的方差由采集系统的噪声决定,并在理论上进行了预测。我们假设在MB破坏过程中,超声回波的相移方差增大。预计该PSV高于静止回波或运动的PSV,从而允许检测代理。该假设在运动幻影中得到了实验验证。在第二个实验中,对非常低浓度的MB进行成像,以证明该方法的灵敏度。结果与理论很好地吻合,并且显示MB比组织的PSV明显增加(44.8 dB)。因此,相移方差可以用于超声造影剂检测。每毫升100个微泡的浓度足以产生可检测的信号,与组织的对比比高达34.7 dB。采集是在一个免费的可编程临床设备上实现的。无需添加或硬件修改,使该方法易于翻译为大多数临床系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Phase shift variance imaging for contrast agent detection
A novel ultrasound contrast agent detection method that selectively detects microbubble (MB) destruction is presented. The detection is based on the variance of the phase shift of consecutive echoes. The variance for stationary echoes or motion at constant speed is determined by the noise of the acquisition system and is theoretically predicted. We hypothesize that the phase shift variance of ultrasound echoes increases during MB destruction. It is expected that this PSV is higher than the PSV for stationary echoes or motion thus allowing the detection of the agent. The hypothesis is experimentally verified in a motion phantom. In a second experiment, MB in very low concentrations are imaged to demonstrate the sensitivity of the method. The results show good agreement with theory and exhibit a clear increase in PSV for MB vs. tissue (44.8 dB). Thus, the phase shift variance can be utilized for ultrasound contrast agent detection. Microbubbles in a concentration of 100 bubbles per ml are sufficient to cause detectable signals with a contrast to tissue ratio of up to 34.7 dB. The acquisition is implemented on a free programmable clinical device. No additions or hardware modifications are necessary making the method easily translatable to most clinical systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信