{"title":"绵羊尿液酸碱变化的物理化学方法与低氯碱中毒","authors":"David Martínez Rodríguez, O. J. O. Espinosa","doi":"10.19052/MV.4394","DOIUrl":null,"url":null,"abstract":"The physical-chemical approach to determine urinary pH is relatively new and has not yet been used in pathological conditions in animals. The main objective of this paper was to demonstrate the validity of this theory in the urine of sheep with hypochloremic metabolic alkalosis. An experimental-type study was conducted to induce hypochloremic metabolic alkalosis in sheep. During the control and induction periods, calculated pH, measured pH, net acid excretion, ammonium and strong ion difference (SID) in urine were examined every 24 hours until development of paradoxical aciduria or physical deterioration of subjects. Pearson’s correlation (r) was determined between measured and calculated pH based on SID in urine. A high correlation between measured and calculated urine pH was observed using SID calculated from net acid excretion (r = 0.874). The correlation between calculated SID and urine pH was significant (r = 0.839). However, the correlation between SID and measured urine pH was moderate (r = 0.588). It is concluded that there is a high correlation between pH calculated from SID using net acid excretion and pH measured in the urine of sheep with hypochloremic metabolic alkalosis. This indicates that urine pH depends strongly on SID and, therefore, a reduction in pH can be explained by a decrease in SID.","PeriodicalId":21407,"journal":{"name":"Revue De Medecine Veterinaire","volume":"29 1","pages":"113-127"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Aproximación físico-química a las alteraciones ácido base en la orina de ovinos con alcalosis hipoclorémica\",\"authors\":\"David Martínez Rodríguez, O. J. O. Espinosa\",\"doi\":\"10.19052/MV.4394\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The physical-chemical approach to determine urinary pH is relatively new and has not yet been used in pathological conditions in animals. The main objective of this paper was to demonstrate the validity of this theory in the urine of sheep with hypochloremic metabolic alkalosis. An experimental-type study was conducted to induce hypochloremic metabolic alkalosis in sheep. During the control and induction periods, calculated pH, measured pH, net acid excretion, ammonium and strong ion difference (SID) in urine were examined every 24 hours until development of paradoxical aciduria or physical deterioration of subjects. Pearson’s correlation (r) was determined between measured and calculated pH based on SID in urine. A high correlation between measured and calculated urine pH was observed using SID calculated from net acid excretion (r = 0.874). The correlation between calculated SID and urine pH was significant (r = 0.839). However, the correlation between SID and measured urine pH was moderate (r = 0.588). It is concluded that there is a high correlation between pH calculated from SID using net acid excretion and pH measured in the urine of sheep with hypochloremic metabolic alkalosis. This indicates that urine pH depends strongly on SID and, therefore, a reduction in pH can be explained by a decrease in SID.\",\"PeriodicalId\":21407,\"journal\":{\"name\":\"Revue De Medecine Veterinaire\",\"volume\":\"29 1\",\"pages\":\"113-127\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revue De Medecine Veterinaire\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19052/MV.4394\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Veterinary\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revue De Medecine Veterinaire","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19052/MV.4394","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Veterinary","Score":null,"Total":0}
Aproximación físico-química a las alteraciones ácido base en la orina de ovinos con alcalosis hipoclorémica
The physical-chemical approach to determine urinary pH is relatively new and has not yet been used in pathological conditions in animals. The main objective of this paper was to demonstrate the validity of this theory in the urine of sheep with hypochloremic metabolic alkalosis. An experimental-type study was conducted to induce hypochloremic metabolic alkalosis in sheep. During the control and induction periods, calculated pH, measured pH, net acid excretion, ammonium and strong ion difference (SID) in urine were examined every 24 hours until development of paradoxical aciduria or physical deterioration of subjects. Pearson’s correlation (r) was determined between measured and calculated pH based on SID in urine. A high correlation between measured and calculated urine pH was observed using SID calculated from net acid excretion (r = 0.874). The correlation between calculated SID and urine pH was significant (r = 0.839). However, the correlation between SID and measured urine pH was moderate (r = 0.588). It is concluded that there is a high correlation between pH calculated from SID using net acid excretion and pH measured in the urine of sheep with hypochloremic metabolic alkalosis. This indicates that urine pH depends strongly on SID and, therefore, a reduction in pH can be explained by a decrease in SID.
期刊介绍:
The Revue de Médecine Vétérinaire publishes four kinds of text:
1) Scientific reviews on subjects related to veterinary and comparative medicine. Suggested length: 10 to 30 typed pages.
2) Original reports on fundamental or applied research. Suggested length: 10 to 15 typed pages.
3) Continuous education articles, that should be easily understandable by non-specialists. Suggested length: 10 to 15 typed pages.
4) Clinical reports. Suggested length: 5 to 15 typed pages.
The publication can be done in French language or English language.
For an article written in English by not english native speakers authors, the manuscript must be subjected by attesting that it was read again by an anglophone scientist or a scientific translator.
The authors must certify that the manuscript was not published or subjected for publication to another review.
The manuscript must be accompanied by a sheet signed by all the joint authors indicating their agreement for the tender of the manuscript.
The publication is free but a financial participation could be required for the photographs color. An estimate will be sent to collect the agreement of the authors.