盐酸洛哌丁胺片剂吸光度法和曲线下面积法分析方法的建立与验证

H. Rivai, Renny Puspita, Sesry Misfadhila
{"title":"盐酸洛哌丁胺片剂吸光度法和曲线下面积法分析方法的建立与验证","authors":"H. Rivai, Renny Puspita, Sesry Misfadhila","doi":"10.9734/bpi/tipr/v3/1696c","DOIUrl":null,"url":null,"abstract":"Development and validation of loperamide hydrochloride tablet method of analysis have been done by using the absorbance method and area under the curve method. This study used methanol and hydrochloric acid 0.1 N (9:1) as the best solvent with maximum absorption at wavelength 259.00 nm. The linearity of loperamide hydrochloride was obtained in the concentration range 200-600 ppm with a correlation coefficient value with the absorbance method and the areas under the curve method were 0.9998 and 0.9865, respectively. The results showed that the levels of loperamide hydrochloride in generic tablets obtained by absorbance method and the area under the curve method were 105.71% and 96.20%, respectively. The results of determination of loperamide levels in tablets of trademark obtained by absorbance method and the area under the curve method were 102.85% and 98.57%, respectively. The level of both samples met the requirements of Pharmacopoeia Indonesia edition V that is 90% -110%. The analysis of loperamide hydrochloride in tablets by ultraviolet-visible spectrophotometry by absorbance method is valid while the area under the curve method is invalid for analysis of loperamide hydrochloride in tablets.","PeriodicalId":22329,"journal":{"name":"Technological Innovation in Pharmaceutical Research Vol. 3","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Recent Study on Development and Validation of Loperamide Hydrochloride Tablet Analysis Method with Absorbance and Area under Curve Methods Spectrophotometrically\",\"authors\":\"H. Rivai, Renny Puspita, Sesry Misfadhila\",\"doi\":\"10.9734/bpi/tipr/v3/1696c\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Development and validation of loperamide hydrochloride tablet method of analysis have been done by using the absorbance method and area under the curve method. This study used methanol and hydrochloric acid 0.1 N (9:1) as the best solvent with maximum absorption at wavelength 259.00 nm. The linearity of loperamide hydrochloride was obtained in the concentration range 200-600 ppm with a correlation coefficient value with the absorbance method and the areas under the curve method were 0.9998 and 0.9865, respectively. The results showed that the levels of loperamide hydrochloride in generic tablets obtained by absorbance method and the area under the curve method were 105.71% and 96.20%, respectively. The results of determination of loperamide levels in tablets of trademark obtained by absorbance method and the area under the curve method were 102.85% and 98.57%, respectively. The level of both samples met the requirements of Pharmacopoeia Indonesia edition V that is 90% -110%. The analysis of loperamide hydrochloride in tablets by ultraviolet-visible spectrophotometry by absorbance method is valid while the area under the curve method is invalid for analysis of loperamide hydrochloride in tablets.\",\"PeriodicalId\":22329,\"journal\":{\"name\":\"Technological Innovation in Pharmaceutical Research Vol. 3\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technological Innovation in Pharmaceutical Research Vol. 3\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9734/bpi/tipr/v3/1696c\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technological Innovation in Pharmaceutical Research Vol. 3","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/bpi/tipr/v3/1696c","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用吸光度法和曲线下面积法建立了盐酸洛哌丁胺片的分析方法并进行了验证。本研究以0.1 N(9:1)的甲醇和盐酸为最佳溶剂,在波长259.00 nm处吸收最大。盐酸洛哌丁胺在200 ~ 600 ppm的浓度范围内线性良好,吸光度法的相关系数为0.9998,曲线下面积为0.9865。结果表明,吸光度法和曲线下面积法测得的盐酸洛哌丁胺仿制片中盐酸洛哌丁胺的含量分别为105.71%和96.20%。吸光度法和曲线下面积法测定商标片中洛哌丁胺含量的结果分别为102.85%和98.57%。两种样品的含量均符合印尼药典V版90% -110%的要求。紫外可见分光光度法测定片剂中盐酸洛哌丁胺含量有效,曲线下面积法测定片剂中盐酸洛哌丁胺含量无效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Recent Study on Development and Validation of Loperamide Hydrochloride Tablet Analysis Method with Absorbance and Area under Curve Methods Spectrophotometrically
Development and validation of loperamide hydrochloride tablet method of analysis have been done by using the absorbance method and area under the curve method. This study used methanol and hydrochloric acid 0.1 N (9:1) as the best solvent with maximum absorption at wavelength 259.00 nm. The linearity of loperamide hydrochloride was obtained in the concentration range 200-600 ppm with a correlation coefficient value with the absorbance method and the areas under the curve method were 0.9998 and 0.9865, respectively. The results showed that the levels of loperamide hydrochloride in generic tablets obtained by absorbance method and the area under the curve method were 105.71% and 96.20%, respectively. The results of determination of loperamide levels in tablets of trademark obtained by absorbance method and the area under the curve method were 102.85% and 98.57%, respectively. The level of both samples met the requirements of Pharmacopoeia Indonesia edition V that is 90% -110%. The analysis of loperamide hydrochloride in tablets by ultraviolet-visible spectrophotometry by absorbance method is valid while the area under the curve method is invalid for analysis of loperamide hydrochloride in tablets.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信